Get complete information related to latest Transducer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transducer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transducer Tenders.
Tender For tender for supply of mcquary make semi-hermetic screw compressore model hsw-205 , crankshaft 68 stroke part no 03341 item 206 , base plate gasket part no 05100 , valve plate comp part no 07845 avail as com as kit/item 201 , gasket 81 5x60x1 part no 05111 , motor pulley , brazed plates type direct expension r134a evaporator , strainer 5 8 ods , vibration eliminator for liquid injection line , vibration eliminator for discharge line , vibration eliminator for liquid line , vibration eliminator for discharge of 20 tr ac plant , base frame for 2 x 4 tr ref plant for nopv class , semi conductor fuses ge feraaz 200a 6 611 rd30-xx0315 , non driving end brg , hooter apex 230v ac , insulation tape , motor replacement gasket & o-ring set , safety valve part no 07940 , shut-off valve nw 50 part no 07131 , filter suction side part no 05983 , shut-off valve nw 38 part no 07671 , tapered compr ring 80x2 chr part no 06367 , oil filter part no 04804 , air cooling unit for cold and cool room of nopv ref plants , air cooling unit for dairy , meat and fish room ref plant nopv , flexible gas charging line , hand held refrigerant leak detector , vacuum pump , coil for evm/evra/evrs danfoss 24v dc 20w code 018f6857 , solenoid valve body danfoss evrs3 1 4 npt m , selector switch , power contractor for soft starter , transformer 300va , ac ammeter ae-rishabh 0-300 900 amps 300 5 ctr 96mm sq , protective cap inside dia 60 0 part no 05854 , base plate part no 04042 , conn rod 148 long w bear part no 04958 item 221 , connecting rod screw m8x55 part no 05940 , front bearing part no 04737 avail as com as kit item 220 , flywheel dia 322 part no 03434 , oil filter replacement gasket and o-ring set , piston dia 80 optim norm part no 07114 item 204 , cathodic bolt , gasket lh side , catch all filter drier filter drier c-032f , set gaskets part no 08492 , upper valve plate gasket part no 06486 , piol.oper. solenoid valve sporlan type 180s with 230v ac coi , lower valve plate gasket part no 06578 , cathode protector for condenser of 4 tr ref plant for nopv , temperature transducer
Tender For supply of pressure transducer type-f part no. 2/520070 make-faiveley for vande bharat [ warranty p eriod: 30 months after the date of delivery ]
Tender For supply, installation and demonstration of electronic torque wrench tester with integrated tor que transducer (dms), torque wrench 90-1100mm as per annexure attached. [ warranty period: 30 mon ths after the date of delivery ]
Tender For supply of following items for setting up measurement and instrumentation lab for 4 year b.tech in electrical engineering curriculum and application for university of calcutta. - experimental set-up for calibration of a wattmeter using dc potentiometer with following features/items:regulated power supply 2 volts, 100 ma to operate the potentiometer.calibrated electronic standard cell voltage 1.0186 volts.regulated power supply 0-5 volts/0.5 amps with milliammeter 0- 500ma for current coil of wattmeter.regulated high voltage power supply 0-250 dc volts with voltmeter 0-250 volts for pressure coil of wattmeter.a panel mounting wattmeter 0-125 watt is required to perform the experimentgalvanometer for null balance.a volt ratio box for measurement of higher voltage.complete circuit diagram with wattmeter connections to be provided on the front panel of the instrument.with standard accessories, experimental set-up for low resistance measurement using kelvin s double bridge with following features:range: 0.2 micro ohm to 11 ohms, with an accuracy of 0.05 %required accessories:spot reflecting galvanometer. dc source 10 a with one analog current meter. attachment of 1 meter length.brass clamp with terminals for zero setting. with standard accessories, experimental set up for unknown capacitance measurement using de-sauty s bridge with following specifications:source: sine wave signal of 1khz. the amplitude of ac switch indicating lamp is provided on the bakelite board. two sockets are to be provided for the output of ac signals.detector: for detecting small ac signals in the output, null detector is required as in-built with digital display.circuit diagram:the circuit layout on the board is to be provided out to facilitate convenient working. 4 or 5 mm socket required for making connection. features:r2 --- three decade resistance dials having value 10 1000, 10 100 and 10 10 ohmsr1 ---- single decade resistance dial having value 10 100 ohmsc1 ---- unknown capacitor.c2 ---- two fixed standard capacitors having value 0.01mfd 0.1mfd (loss free)with standard accessories, experimental set-up for calibration of a 1-phase watt-hour meter with following scopes: to adjust & calibrate a single-phase energy meter by direct loading method to adjust & calibrate a single-phase energy meter by comparing with a sub-standard meterspecifications: static energy meter single phase: under test (local) duly mounted, wired and terminated static energy meter single phase: sub-standard meter (isi mark) duly mounted, wired and terminated voltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v ac ammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a ac wattmeter: dynamometer type ac single phase, multi-range with current coil 5 / 10 amp and potential coil 75 / 150 / 300 v ac variac: variable voltage transformer (portable table / floor mounting type with enclosure) input: 230v ac and output: 0 270v / 8 amp ac variable load: made up of 3 load resistors of 70 ohms / 700 w each duly mounted and connected / terminated to form different loads (35 to 210 ohms) as per external connections digital stop clock: portable with start / stop & reset operation set of necessary 4 mm spring loaded patch cords for interconnections detailed instruction manual supply to be connected: 230v, 1phase, 50 hz, ac mains, experimental set-up for calibration of a 3-phase watt hour meter with following specifications: to adjust & calibrate a three-phase energy meter by direct loading method to adjust & calibrate a three-phase energy meter by comparing with a sub-standard meterspecifications:static energy meter three phase: under test (local) duly mounted, wired and terminatedstatic energy meter three phase: sub-standard meter (isi mark) duly mounted, wired and terminatedvoltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v acammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a acwattmeter: