Tender For auction sale of depot ferrous scrap - pl no.98097027 condemned and unserviceable ferrous c.i.scrap consisting of released p.way and signal materials such as sej chair,signal point machine body , signal aspect, offset bracket,ct box,e/hp type locks, signal post base, signal lever frame arrangements, control terminal boxes (ctb), cylindrical weight, gate boom weight, l.c gate support,boom lock ground lever,heel block, a base,c i beam,pulleys,trestle and released under ground water pipes - broken into small pieces and dismantled weigh machines with/without parts and fittings and c.i bearing plates, cst 9 plate, slide chair, c.i. pots, c.i. blocks, distant blocks, d bracket, and other similar items of c.i. in nature.all the above items are of sorts and sizes, full/part, damaged/broken, with/without m.s attachments. note: (1) crane loading permitted (2) n.f. attachments,if any, should be removed and handed over to the rlys.
Tender For repairing of switchyard works including ct/pt junction box replacement, control cable replacement, cable trench repair, secondary panels for station transformers, ngr fail-safe relay repair including cable tray installation at main substation and sh
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For auction sale of iron scrap,acbs 2000 a,marshallig box scrap,ct & pt combined unit,shunt capacitor off sizes,mix internet & fiber cable scrap,all size porcelain insulators
Tender For auction sale of depot miscellaneous scrap - cond and ohe/trd scrap vacuum circuit breaker, vacuum interruptor, at,ct, bt. rs kv,132 kvsf operation box,pt25 kv,cb alind 25 kv,bm-cgl,alind, cb mechinical 25kv ,kva/aux transformer, current transformer 132 kv and power capicitor, with chini mitti insulator with nf attachment, sort and sizes, broken and unbroken, as is where is basis as it is.
Tender For auction sale of ct/pt units,ms iron scrap etc.,aluminium scrap etc.,governor and electro hydraulic governor etc.,governor and electro hydraulic etc.,u/s rubber tube off size etc.,dc excitor rotor poles etc.,empty steel drum 210 ltr. etc.,half x-arm,pcc broken poles off size,drill/chucks etc.,11kv pilca o/d cable box 95 mm (1/core) etc.