Tender For design, supply, supervision of eraction, testing and commissioning of transformer of rating 3.15 mva, copper wound, 33/11 kv, oltc, as per is 2026(part 1) 2011 (with latest amendment). suitable f or parallel operation of existing transformer 3.15 mva. including with rcc foundation, netural earthing, inc luding cable laying, trench etc. as per site requirement. including transportation loading, unloading charge s. location of installation at new katni junction katni (mp). [ warranty period: 60 months after the date o f delivery ]
Tender For transportation of 132/33 kv, 20/25 mva transformer with oil drums & allaccessories including rtcc panel loading from 220kv gss ratangarh tounloading on transformerfoundation (500 km approx.) at 400kv gssbarmer
Tender For repairing of explosion prevention and fire extinguishing system safety of 3 mva /11 kv/3.3 power transformer make ctr mfg ind pvt ltd, 1 mva transformerfoundation an repairing of oil soak tank for 3 mva transformer at main substation tnocp under ha
Tender For supply of antivibration foundation mounting for abb make transformer radiator blo wer motor as per drawing no. wr/mx/el-1941-3-84-ac-dc- 274. as per drg.no. wr/mx/el-1941- 3-84-ac-dc- 274 [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of goods, tools & equipmentforan international standard itotin electrician tradeat iti vyara, gujarat, india - electrical machine trainer suitable for demonstrating the construction and functioning of different types of dc machines and ac machines (single phase and three phases). should be fitted with friction brake arrangement, dynamometer, and instrument panel and power supply unit., motor-generator (ac to dc) consisting of: squirrel cage induction motor with star-delta starter and directly coupled to dc shunt generator and switch board mounted with regulator, air breaker, ammeter, voltmeter, knife blade switches and fuses, set complete with case iron and plate, fixing bolts, foundation bolts and flexible coupling. induction motor rating: dc shunt generator rating: induction motor rating: dc shunt generator rating:, motor generator (dc to ac) set consisting of-shunt motor with starting compensator and switch directly coupled to ac generator with exciter and switch board mounted with regulator, breaker, ammeter, voltmeter frequency meter, knife blade switch and fuses etc. set complete with cast iron bed plate, fixing bolts, foundation bolts and flexible coupling. shunt motor rating: ac generator rating:, linear i.c. trainer, digital i.c. trainer, component of typical small hydro power, component of typical water mill, low voltage control and systems. with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, residential and small business systems with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, building control systems and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, industrial control system and automation with suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, solar system lab suitable tables, circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the experiments by the student, training system predictive maintenance and condition monitoring of electric drives, electric vehicle motors and battery training & test bench, industrial electrical testing facility with circuits, power supply, control units, software, hardware, wiring, switches ready to conduct the testing by the student, ar-vr training set up., portable electric drill machine, pillar electric drill machine, outside micrometer, motorized bench grinder, rawl plug tool & bit, hydrometer, thermometer, soldering iron, copper bit soldering iron, de soldering gun, table vice, ohm meter; series type & shunt type, stock and dies conduit, multi meter (analog), digital multi meter, a.c. voltmeter, milli voltmeter, d.c. milliammeter, ammeter, a.c. ammeter, a.c. ammeter, kilo wattmeter, a.c. energy meter, power factor meter, frequency meter (analog + digital), tachometer with stopwatch, current transformer primary-, potential transformer, growler internal+ external, tong tester / clamp meter, megger, wheat stone bridge with galvanometer & battery 2 nos, earth tester
Tender For construction of chilling tank, radiator header support foundations, fan support foundations and pipe support foundation for 160 mva t/f (emco make) (to replace damaged 100 mva transformer) at 220 kv sub staion amariya pilibhit
Tender For civil, architectural works in foundations, civil superstructure for main power house building, tg deck, ccr, service building, transformer yard, switchyard, pipe/cable rack foundation, miscellaneous bldgs. of u#1 and u#2 for 2x800 mw singrauli stpp stage iii
Tender For supply erection testing and commissioning of equipments at 132/33kv grid station canal - supply of main equipments at 132/33kv grid station canal, auxillary transformer 33/0.433kv, 250kva 3-phase distribution transformer with bimetallic terminal connectors energy level-2, copper wound, battery bank 110 v,300ah of 55 no cells of 2 volt each,sealed maintt. free vrla type, high impact polyprophelene co-polymer container, flame retardant, 110v battery charger (3-phase) (i) float charging and load current ratings 30a/60a/70a/100a at 220v to 252v dc (ii) boost charging current rating : 50a/55a/60a/70a/80a/100a at 198v to 296/302v dc, 33kv vcb indoor type, 1600a with offered operating mechanism. complete in all respects fitted with indoor ct of ratio 1200-600-300/1-1a with 1 spare vacuum interruptor and one indoor type ct set . the vcb shall be compatabile for installation with bus bars of existing indoor type (1+2)bank, 33kv control and relay auxilliary panel completely wired including sub-station automation supporting ieds/numerical relays of make abb/siemens/ge micom/alstom/schneider with iec 61850 compatibility, 70sq.mm 3 core aluminium cable, 1.1kv grade, unarmoured, pvc insulated stranded conductor frls type, 2-core, 6 sq.mm, 1100v, pvc insulated, pvc sheathed, frls, galvanised steel wire/strip armoured stranded copper conductor control cable complete, iron clad change-over switch 300a ( 3 phase), ms-round bars 40mm dia, gi flat (ms) 50x6mm, earth-pit (treated) 3m, cable termination kits 300 sq. mm outdoor, erection of main equipments and write back of dismantled equipments to the divisional store janipur, auxillary transformer 33/0.433kv, 250kva 3-phase distribution transformer with bimetallic terminal connectors energy level-2, copper wound, battery bank 110 v,300ah of 55 no cells of 2 volt each,sealed maintt. free vrla type, high impact polyprophelene co-polymer container, flame retardant, 110v battery charger (3-phase) (i) float charging and load current ratings 30a/60a/70a/100a at 220v to 252v dc (ii) boost charging current rating : 50a/55a/60a/70a/80a/100a at 198v to 296/302v dc, 33kv vcb indoor type, 1600a with offered operating mechanism. complete in all respects fitted with indoor ct of ratio 1200-600-300/1-1a with 1 spare vacuum interruptor and one indoor type ct set . the vcb shall be compatabile for installation with bus bars of existing indoor type (1+2)bank, 33kv control and relay auxilliary panel completely wired including sub-station automation supporting ieds/numerical relays of make abb/siemens/ge micom/alstom/schneider with iec 61850 compatibility, 70sq.mm 3 core aluminium cable, 1.1kv grade, unarmoured, pvc insulated stranded conductor frls type, 2-core, 6 sq.mm, 1100v, pvc insulated, pvc sheathed, frls, galvanised steel wire/strip armoured stranded copper conductor control cable complete, iron clad change-over switch 300a ( 3 phase), ms-round bars 40mm dia, gi flat (ms) 50x6mm, earth-pit (treated) 3m complete including civil works as per drawing, cable termination kits 300 sq. mm outdoor, civil work construction of foundation for auxilliary transformer complete as per drawing (7cum), tool kit