Tender For corrigendum : research based pilot project [dynamic feeder voltage manager (dfvm)] for turnkey based work of design, development, supply, installation, testing & commissioning of 3-ph, 50 hz, 4000 kva, 12/12kv outdoor onan auto/power transformers equipped with on-load tap changer (oltc) with necessary infrastructure and protections, master controller and around 100 modems, control circuits with comprehensive maintenance contract for 05 (five years) after handing over the project
Tender For supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with on load tap changer, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with on load tap changer, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For corrigendum : tggenco-cetd- supply of certain consumables of flash point test kit, interfacial tensiometer required in transformeroiltesting lab/cetd/tggenco for the year 2026-27
Tender For providing of operation and maintenance power house / power plant - carried out in connection with complete overhaulingof 15mva, 15.75/6.9kv uat-10a & 10b along with on load tap changer of 200mw unit no.10
Tender For corrigendum : supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with on load tap changer, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of testing of earth pit , testing of relay , thermography of equipment , preparation of earth pit layout , testing of insulation mat , load testing of battery bank , transformeroiltesting , testing of transformer tan delta , testing of transformer partial discharge , routine testing of transformer , servicing and testing of vcb , wti winding temperature indicator calibration , oti oil temperature indicator calibration , buchholz relay testing , testing of third harmonic la , testing of vcb bottle , vlf testing of cable 100 percent , polarization index testing motor , insulation resistance testing , electrical safety audit , calibration of voltmeter , calibration of ammeter , cablibration of energy meter , cablibration of power factor meter , acb servicing and testing , pair of ht electrical gloves, 25 kv, is 13774 2021 , pair of lt electrical gloves, 1.1 kv, is 4770 1991 , insulation mat 2.5 mm, lt, is 15652 , insulation mat 3 mm, ht, is 15652 , oltc oiltesting as per is 1866 , dga of transformeroil , transformeroil filtration , thermal omicron b2hv relay test , testing of mccb , testing of rccb , pi of power cables , current transformertesting , digital megger meter , led 300 watts for high mast tower , digital ampere meter , communication cable tester , digital clamp meter * /bid number : gem/2026/b/7664367 + /dated: 17-06-2026 ' ' / bid document 1 / 51