Tender For providing electrification and street light in sector-87 faridabad supply and erection of pcc pole, acsr conductor, 300sqmm x 3 core tr-xlpe cable, 100kva transformer and street lights and all other works contingent thereto. (including defect liabil
Tender For 2 pole roller fitted limit switch consisting of limit switch body as per part no.zcd21 with 1 no +1nc contact block as per part no.xe2sp2151 suitable and compatible for feedback of prv in a bb make main transformer of 3phase emu/memu coaches. make:schneider telemecanique or similar. firm should provide oem authorization and previous supply proof of same equipment. [ warranty pe riod: 30 months after the date of delivery ]
Tender For bid to ras supply of xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) (q2) , mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2) , supply install testing commissioning of step down transformer indoor type voltage rating ht11 bye zero point 433 kv out door type of capacity 200 kva level 2 3 phase 4 wire 50 hz , supply laying and testing 11 kv earthed grades cable xlpe 120 sqmm 3 core , s and f cable end jointing kit for 11 kv grade cable for outdoor termination heat shrink type cable end complete with jointing material and accessories , s and f cable end jointing kit for 11 kv grade cable for outdoor termination heat shrink type cable end , material and labour for pcc 1 ratio 4 ratio 8 type d2 using 40 mm graded stone aggregate for making good cutting portion mass concrete , m and l for pcc 1 ratio 3 ratio 6 type c2 using 40 mm graded stone aggregate for making good cutting portion mass concrete filling of foundations etc including necessary use and waste of form work , supply and fix tpn distribution board 4 way acrylic door 415 volts ac tpn for flush mounting with 100 amps double door copper busbar neutral bar earth bar and mcb incomer of rating upto 100amps , material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directely in ground vertically , supply install testing and commissioning of lt feeder panel of size 1500 x 1500 x 600 mm 3 phase 4 wire 415 v 50 hz ac outdoor type , m and l for brick sub class b 250x115x75 mm and laid in trenches as in protection of ug cable , supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover , returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed , removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1 point 5 mtr above the starting point all as specified and directed , m and l for gl pipe 100 mm light grade laid in trenches floors bye on pole bye road for cable protection with all fittings complete all as specified and directed , boaring holes horizontally under road without damaging the surface of road minimum1pointzero mtr bellow the road surface with the help of gl tubing of any dia not exc 80mm dia for passing of ug cable , supplying and laying reinforce precast concrete cable cover class ht type 1 flat size 300 x180x40 mm for protection under ground ht cable complete all as specified and directed
Tender For corrigendum : for running contract for hon,ble sansad nidhi/vidhayak nidhi and other deposit works under edd-budaun (semi turnkey). - cartage of following material from store center nawada, budaun to je store/je store to site of work including loading & unloading at both ends maximum distance up to 30 km., a) pcc pole 8.5 mrt long/st pole 11 mtr long., b) 11 kv xlpe cable of 3x70/3x120/3x185/3x300 sq.mm., c) 250/400 kva t/f., d) 11 kv ct/pt unit of different size, e) 11 kv jointing kit of different size, f) 11 kv pilfer proof cubical of different size, g) lt abc cable of size 1x16, 3x50, 3x95, 3x120 sq.mm., cartage of line material (11 kv pin insulator, disc insulator, stay set, cross arm, gi wire, earthing rod, ms channel, ms angle, etc) from store centre to dump site & then dump site to site of work on day to day basis, including loading & unloading at both ends maximum distance up to 30 km., cartage of 10 kva & 25 kva transformer from store centre to site of work including loading & unloading at both site, the work of safe carriage 11 kv o/g vcb store center nawada budaun to work of site distance up to 0 to 30 km including safe loading & unloading., cartage of 63 kva to 100 kva transformer from store centre to site of work including loading & unloading at both site., earthing of each 11 kv line pole & t/f properly after drive of electrodes if size 20mmx250mm and connection the earthing point with gi wire., erection of pcc pole 8.5 mtr long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., erection of stp pole 11 mrt long after digging a pit of size 1.20 x 0.60 x 1.6 mtr in all type of soil including back filling of the pole with proper ramming after completion of work., fabrication and fixing of all 11 kv h.t/l.t. line accessories., erection of double pole on pcc pole 8.5 mtr/stp 11 mtr. long after digging of pit of required size including fabrication and fixing of top channel, droper channel & base channel alongwith, fixing all 11 kv accessories, fuse set 11 kv pin insulators and making connection properly., construction of new plinth for 250/400 kva as per uppcl norms, mounting of 250/400 kva t/f on plinth as per uppcl norms, providing and fixing wiremess fencing for 250/400 kva, erection/installation of following of vcb o/g in consumers site and cable joint of the panel to including earthing, grouting, anchor bolt of panel of making/repairing of pocket for cable to insert in panel form trench and fixing taping of busbar with wiring for ac,dc connection including providing ac and dc supply., chemical earthing for 250/400 kva t/f neutral and body complete, chemical earthing for vcb o/g, mounting of 10 & 25 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of 63 & 100 kva t/f with proper jumping of ht side and fixing of cable on lt. side of t/f making connection properly., mounting of ct/pt unit with proper jumping of ht side and fixing of cable on lt. side of meter cubical properly, fixing of meter cubical as per uppcl norms, making a section pole to exist pole after fabrication & fixing of t channel fixing of all 11 kv accessories., erection of stay rod complete after digging a pit of size 1.20 x 0.60 x 1.6 mtr and grouting the same in block of size 0.60 x 0.60 x 0.30 mtr and nuzzling at the both ends and filling the pit with excavated earth soil with proper ramming., laying lifting stringing of proper sagging of acsr weasel/rabbit/dog conductor for 3 phase, 3 wire 11 kv line including binding & jumpering properly., laying lifting stringing of proper sagging of 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm., laying of underground 11 kv xlpe cable of 3x70, 3x120, 3x185, 3x300 sq.mm. sizes with open trench by brick & sand as per uppcl norms., filling the 11 kv jointing kit (joint kit providing by c
Tender For corrigendum : supply of 22kv/? 3/110/? 3-110/? 3v single pole voltage/ potential transformer for c&s make breaker panel , 20/1a 10/1 a current transformer for 22 kv kirloskar switchgear panel