Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - transmissionline; electrical system or installation; buyer
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - transmissionline; electrical system or installation; buyer
Tender For supply of electrical ee2 d d -experimental kit for the measurement of displacement using lvdt 6 , experimental kit for the measurement of displacement using lvdt 7 , inductive load bank 1 , inductive load bank 2 , kelvin double bridge 1 , kelvin double bridge 2 , kelvin double bridge 3 , kelvin double bridge 4 , kelvin double bridge 5 , kelvin double bridge 6 , m. i type analog ammeter 0 1 a 1 , m. i type analog ammeter 0 1 a 4 , m. i type analog ammeter 0 1 a 2 , m. i type analog ammeter 0 1 a 3 , m. i type analog ammeter 10 20 a , m. i type analog ammeter 2. 5 5 a 1 , m. i type analog ammeter 2. 5 5 a 2 , m. i type analog ammeter 5 10 a 1 , m. i type analog ammeter 5 10 a 2 , m. i type analog ammeter 5 10 a 3 , m. i type analog ammeter 5 10 a 4 , m. i type analog ammeter 5 10 a 5 , megger hand driven 1 , megger hand driven 2 , megger hand driven 3 , megger hand driven 4 , megger hand driven 5 , mi type analog voltmeter 125 250 500v , mi type analog voltmeter 300 600v 1 , mi type analog voltmeter 300 600v 2 , mi type analog voltmeter 300 600v 3 , mi type analog voltmeter 300 600v 4 , mi type analog voltmeter 300 600v 5 , mi type analog voltmeter 75 150 300v 1 , mi type analog voltmeter 75 150 300v 2 , mi type analog voltmeter 75 150 300v 3 , network theorem trainer kit 1 , network theorem trainer kit 2 , network theorem trainer kit 3 , orifice meter measurement setup 1 , orifice meter measurement setup 2 , orifice meter measurement setup 3 , phase sequence indicator 1 , phase sequence indicator 2 , rheostat 0 100 ohm,2. 5a , rheostat 0 100 ohm,5a 1 , rheostat 0 100 ohm,5a 2 , rheostat 0 250 ohm, 2. 5 a 1 , rheostat 0 250 ohm, 2. 5 a 2 , rheostat 0 250 ohm,1a , rheostat 0 50 ohm,5a , rheostat 0 500 ohm, 2. 5 a , rotameter flow measurement setup 1 , rotameter flow measurement setup 2 , rotameter flow measurement setup 3 , rtd temperature measurement setup 1 , rtd temperature measurement setup 2 , strain gauge trainer kit 1 , strain gauge trainer kit 2 , strain gauge trainer kit 3 , strain gauge trainer kit 4 , strain gauge trainer kit 5 , strain gauge trainer kit 6 , three phase load rheostat 1 , three phase load rheostat 2 , three phase load rheostat 3 , three phase load rheostat 4 , three phase load rheostat 5 , three phase power factor meter 1 , three phase power factor meter 2 , three phase power factor meter 3 , three phase power factor meter 4 , three phase power factor meter 5 , three phase synchronous motor coupled with dc shunt generator setup 1 , three phase synchronous motor coupled with dc shunt generator setup 2 , three phase synchronous motor coupled with dc shunt generator setup 3 , three phase synchronous motor coupled with dc shunt generator setup 4 , three phase veriable resistive load 1 , three phase veriable resistive load 2 , three phase veriable resistive load 3 , transmissionline protection simulation kit 1 , transmissionline protection simulation kit 2 , transmissionline protection simulation kit 3 , transmissionline protection simulation kit 4 , transmissionline simulator 1 , transmissionline simulator 2 , transmissionline simulator 3 , undrground cable fault locator 1 , undrground cable fault locator 2 , undrground cable fault locator 3 , venturi flow measurement setup 1 , venturi flow measurement setup 2 , venturi flow measurement setup 3 , wattmeter 0. 5 1a, 150 300v low power factor , wattmeter 10 20 a ,150 300 600v unity power factor 1 , wattmeter 10 20 a ,150 300 600v unity power factor 2 , wattmeter 10 20 a ,150 300 600v unity power factor 3 , wattmeter 10 20 a ,150 300 600v unity power factor 4 , wattmeter 10 20 a //bid details2 / 127,150 300 600v unity power factor 5 , wattmeter 10 20 a ,150 300 600v unity power factor 6 , wattmeter 2. 5 5a , 150 300v unity power factor 1 , wattmeter 2. 5 5a , 150 300v unity power factor 2 , wattmeter 2. 5 5a , 150 300v unity power factor 3 , wattmeter 2. 5 5a , 150 300v unity power factor 4 , wattmeter 5 10 a ,150 300 600v unity power factor 1 , wattmet
Tender For tender for estimate for shifting of 22 kv ht lines due to construction of 66 kv d/c transmissionline from pragatinagar to hulli in esd, baghi under electrical division, hpsebl, jubbal. (tender on semi turn key basis)
Tender For providing of custom bid for services - repair and replacement - this is regarding the administrative and financial approval for the work related to rectifying the sf6 gas leakage in the 145 kv sf6 circuit breaker on the 132 kv gaon-sidhawali line at the 220 kv baraut substation, and addressing the technical fault in the operating mechanism of the circuit breaker on the 132 kv baraut-sbc sugar mill line, under the electrical transmission division, baraut.
Tender For survey investigation, design, supply, installation, testing and commissioning of tank filling scheme consisting of construction of intake channel, forebay, jack well cum pump house, power supply including terminal bay, transmissionline, electrical substation, rising main, distribution network, delivery chamber, gravity main network, various types of valves, receiving chambers, staff quarters, surge protection system for filling of 22 tanks in kambadal hosur and surrounding villages by lifting 0.19 tmc of water from bhadra river near gonibeedu village of bhadravathi taluk, shimoga district including operation and maintenance for a period of 5 years after successful completion of work for kambadal hosur tank filling scheme on turn-key basis
Tender For design, supply, erection, testing, commissioning of 2x25 kv ohe and psi system (tss's sp's and ssp's) including electrical general services, engineering works between urukere (excl.) (ch:11/687) to tavarekere (incl.) (ch:66/400) and chitradurg (excl.) (ch:142/920) t0 tolahunse (excl.) (ch:192/524) of tk-dvg section (104.317 rkm/128.013tkm) along with design, supply, erection, testing, commissioning of 220kv/25kv traction substation at chikkamagaluru and shikaripura with transmissionline provision from gss