Tender For tender for permanent restoration of power supply of 11 kv ht line at village deriya, don thada, sohal, kabdi and lt line damage at villagetaliya, dhar pajera,thada, sohal and s/area damage due to heavy storms/rain on dated 2and3/05/2025 uesdrajgar
Tender For tender for permanent restoration of power supply of 11 kv ht line at village methli,blaindhar, deeda and lt line at village nehog, tonda, tendula, ser, piriyadhar and s/area damage due to heavy storms/rain on dated 21/05/2025 under esd charna
Tender For supply and complete installation of conference room audio video system e e - chairman microphone , delegate microphone , intelligent conference controller , phantom power microphone line input with usb , two way wall mount speakers , amplifier , multiview switcher , ptz camera , presentation device , handheld microphone , hdmi matrix switcher , hdmi transceiver , cables and connectors , rack , services for installation
Tender For corrigendum : provision of skilled manpower for working on power supply, traction, ohe and scada systems provided on metro line 2b ph-1, mandala depot ph-1, line-9 ph-1 and 7a for an initial period of two years
Tender For supply of over head line inspection with video recording using global positioning system fo r current collection test (oliver-g) as per rdso specification no is/rdso-ti/00001:2023 or its lat est version including gps data mapping instrument. the hardware configuration prescribed fo r laptop and other electronic equipments in the above referred rdso specification is minimum requirement and higher configurations / specifications is also acceptable if it improves the ov er all performance of the system.the complete system should be supplied to consignees given below an d should be successfully installed tested and commissioned. the offered price should be inclusive of installatio n testing and commissioning at the consignees desired locations. also additional power bank for increasing bac kup till 8 hrs [ warranty period: 30 months after the date of delivery ]
Tender For electrification & power supply arrangement of various service buildings; removal of cable infringements & relaying of cables, provision of pumps, provision of lighting arrangement and other associated electrical works in asangaon - kasara section in connection with kalyan kasara 3rd line in mumbai division of central railway.
Tender For supply and installation of some articles to the residential office of the honble deputy speaker, tripura legislative assembly, bardowali, agartala during the year 2025-26 - providing of split type high wall 2.00 tr (rated cooling capacity should not be less than 6,000 kcal/hr or 24000 btu/hr or 7000 kw) split a.c. machine with inverter compressor technology operating on non-cfc refrigerant (r-410a/r-32/equivalent refrigerants) suitable for wall mounting conforming to is:1391 (part-ii) specification (evaporator & condenser must be of pure copper) not less than 3 (three) star rating (latest standard), operates on single phase 230 volt, 50hz, ac supply maximum current drawn 11.0 ampere, including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power top etc complete, capable of performing a) cooling b) dehumidifying c) air circulation d) filtering as per direction of the engineer-in-charge., standard installation of 1.5 tr/2.00 tr capacity high wall split air conditioner i/c providing of electrical plug top of required capacity, flling up/ repairing of drilled portions by cement mortar, painting etc. as per direction of the engineer-in-charge., fabrication of m.s. platform for placement of condensing unit by using m.s. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the engineer-in-charge., providing hard pvc pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the engineer-in-charge., supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 tr & 2 tr ac) beyond the standard length as per direction of the engineer-in-charge. (if required), providing and connecting electric control cables between mcb to indoor/outdoor. 3c x 2.5 sq. mm copper cable., supplying & fixing of 1200 mm sweep white color ac ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm pvc insulated copper conductor cable(fr) (isi marked, bee 1 star/minimum service value 4.0 m /min/w): -, supplying and fixing of 20 mm dia extra down rod (gi pipe medium guage) with necessary hole for installation of ceiling fan as required., wiring for light/fan/ exhaust fan/ call bell point with 2x1.5 sq. mm pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ walt complete with 6/10 amps modular type switch, cover plate, gl box including necessary connection etc. as required, supplying and fixing of the following modular accessories including necessary connection etc. as required 3/6 pin 16/20 amps socket outlet (2m), supplying and fixing of the following modular accessories including necessary connection etc. as required4 step fan regulator (1m), supplying and fixing of the following modular accessories including necessary connection etc. as required20/25 amps single phase motor starter switch (2m), wiring for circuit/sub-main with the following sizes pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ wall etc. as required, earthing with 40 mm dia g.i. earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top cl cover plate size 12"x 12" having locking arrangement including cc work, holes on earth pipe etc. as required, proving and fixing/drawing of 4.06 mm dia (8 swg) g.i. 10 wire on surface or in existing g.j/pvc/ polythene pipe for loop earthing as required., executive desk with return unit, size: 2100(w)x 2250(d) x 750 (h) mm, executive revolving chair, visitor chair, godrej 4 door bookcase (1742 h x 914 wx 320 d) mm
Tender For corrigendum : erection work of s/c line on d/c panther tower from 220kv tappar ss to m/s executive engineers(mps-2)rapar(khokhara) for catering 22500 kva new power demand at 66kv voltage class in respect to m/s executive engineer,kutchh irrigation division bhuj, for unit mps2 located at survey no.690/5/p1 and 690/5/p2 of village:rapar(khokhara),tal:anjar,dist:kutchh
Tender For construction of 11 kv line and installation of dtr for proposed solar power plant as requested by aditya mahara under bans chandak section of edd pithoragarh