Tender For construction of 11kv underground double circuit feeder from 33/kv sub-station ess-03(pocket-2b) to existing feeder on 100mtr.wide road in front of pocket-4a, sector -18,yea wc-( e m -03)
Tender For corrigendum : 11kv badalpur underground feeder single circuit convert to double ckt. hence laying of single circuit parellel with existing single circuit. provision of double circuit cable under bridge by 3x185sqmm xlpe for making spare for 11kv roopwas, old rail
Tender For corrigendum : construction of diversion weir at the offtake point of the markandeya river at pachapur village to create a pool of water to divert the water from the river to the main pump house though the intake channel. supply, installation, testing and commissioning of pumping machinery of balance 03 nos out of (5w plus 1s) of vt of capacity 2830 hp to carry discharge of 0.914 cumecs at 187.8 m head along with electrical works for the main pump house. design, supply, erection, testing and commissioning of one power transformer of adequate capacity of 15 mva to meet the load requirement of main pump station for 110kv/6.6kv. construction of balance rising main for 4.752 km of pipe dia 1500 mm to 1200 mm in the main pump house from ch 18.830 km to ch 23.582 km at the delivery chamber-2 near mallapur village with necessary valves, chambers, crossings, thrust and anchor blocks. construction of bleeder of length 0.747 km, which conveys the discharge of 1.67 cumecs from the raising main at ch 19.377 km to delivery chamber-1 proposed adjacent to second pump house at hanabaratti village. construction of delivery chamber 1 adjacent to second pump house near hanabaratti tank. construction of second pump house and its allied works. supply, installation, testing and commissioning of pumping machinery with 3 nos (2w plus 1s) of vt of capacity 1500 hp to carry peak discharge of total 1.67 cumecs at 110 m head, along with electrical works for the second pump house. construction of pressurized bulk feeder no.4 of length 12.2 km, from the end of manifold system of second pump house to delivery chamber-3 at suthagatti village with necessary valves, chambers, crossings, thrust and anchor blocks, surge analysis & surge protection works. construction of delivery chamber - 2 at the end of rising main near mallapur village. construction of delivery chamber - 3 near suthagatti village, at the end of pressurized bulk feeder - 4 taking off from second pump house. supply, jointing, laying, testing and commissioning of pipe distribution network consisting of bulk feeder lines, mains, sub mains and sub feeders with ms/hdpe pipes of required pressure rating for conveying water under each blocks up to 20 ha sub chak, with necessary valves, chambers, crossings, thrust and anchor blocks. construction of security quarter, approach road and protection works all around the second pump house layout. construction of service road along the pipeline alignment for bulk feeders and main lines. transmission line from source sub stations to the second pump house with a switch yard with receiving tower,33kv vcb circuit breaker,33/6.6kv power transformers,6.6kv incomer ht pannel,110vdc battery and battery charger with dcdb,6.6kv 150kvar bus capacitor pannel,6.6/0.415kv auxiliary transformer,6.6kvht soft stater panel with capacitor,415v lt pcc pannel,6.6kvht electrical motors, lt load, other general items and safety accessories. operation and maintenance of the scheme for 5 years.
Tender For supply, installation, testing and commissioning for shifting/re-alignment of existing 11kv line on double circuit saboo and sos feeder on 11mtr flanged st pole on full turnkey basis under ut capex 2024-25
Tender For office of addl. se, ds division abohar, regarding laying railway underground crossing with double circuit 11 kv 3/c 150mm xlpe cable through 160mm hdpe pipe for new 11 kv chirag dhani feeder at location km 74/8-9 & tpno. 74862 between abs-klwl railway stations corrigendum-01
Tender For erection of new 132kv circuit breaker by laying new foundation and dismantling of old 132kv circuit breaker and existing foundation for 132kv zaheerabad feeder at 132kv sadasivpet ss in o&m division, yeddumailaram as directed by the site engineer- (electrical and civil works).
Tender For corrigendum : construction of 220 160 mva and 132 kv 50 mva gss at hindore rajiasar distt sriganganagar in rajasthan including survey supply of all smaterials erection including civil works testing and commissioning turnkey project - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1250 a, 25 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 50/31.5/25 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specification, lighting panel typ
Tender For corrigendum : construction of 220/132 kv, 1x160 mva and 132/33 kv, 1x40/50 mva gss at 220 kv gss kolayat (distt-bikaner) in rajasthan including survey, supply of all equipments/materials, erection (including civil works), testing and commissioning (turnkey ) - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1600 a, 31.5 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 40/50 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specifica