Get complete information related to latest Transmitter Pressure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transmitter Pressure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transmitter Pressure Tenders.
Tender For supply of following items for setting up measurement and instrumentation lab for 4 year b.tech in electrical engineering curriculum and application for university of calcutta. - experimental set-up for calibration of a wattmeter using dc potentiometer with following features/items:regulated power supply 2 volts, 100 ma to operate the potentiometer.calibrated electronic standard cell voltage 1.0186 volts.regulated power supply 0-5 volts/0.5 amps with milliammeter 0- 500ma for current coil of wattmeter.regulated high voltage power supply 0-250 dc volts with voltmeter 0-250 volts for pressure coil of wattmeter.a panel mounting wattmeter 0-125 watt is required to perform the experimentgalvanometer for null balance.a volt ratio box for measurement of higher voltage.complete circuit diagram with wattmeter connections to be provided on the front panel of the instrument.with standard accessories, experimental set-up for low resistance measurement using kelvin s double bridge with following features:range: 0.2 micro ohm to 11 ohms, with an accuracy of 0.05 %required accessories:spot reflecting galvanometer. dc source 10 a with one analog current meter. attachment of 1 meter length.brass clamp with terminals for zero setting. with standard accessories, experimental set up for unknown capacitance measurement using de-sauty s bridge with following specifications:source: sine wave signal of 1khz. the amplitude of ac switch indicating lamp is provided on the bakelite board. two sockets are to be provided for the output of ac signals.detector: for detecting small ac signals in the output, null detector is required as in-built with digital display.circuit diagram:the circuit layout on the board is to be provided out to facilitate convenient working. 4 or 5 mm socket required for making connection. features:r2 --- three decade resistance dials having value 10 1000, 10 100 and 10 10 ohmsr1 ---- single decade resistance dial having value 10 100 ohmsc1 ---- unknown capacitor.c2 ---- two fixed standard capacitors having value 0.01mfd 0.1mfd (loss free)with standard accessories, experimental set-up for calibration of a 1-phase watt-hour meter with following scopes: to adjust & calibrate a single-phase energy meter by direct loading method to adjust & calibrate a single-phase energy meter by comparing with a sub-standard meterspecifications: static energy meter single phase: under test (local) duly mounted, wired and terminated static energy meter single phase: sub-standard meter (isi mark) duly mounted, wired and terminated voltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v ac ammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a ac wattmeter: dynamometer type ac single phase, multi-range with current coil 5 / 10 amp and potential coil 75 / 150 / 300 v ac variac: variable voltage transformer (portable table / floor mounting type with enclosure) input: 230v ac and output: 0 270v / 8 amp ac variable load: made up of 3 load resistors of 70 ohms / 700 w each duly mounted and connected / terminated to form different loads (35 to 210 ohms) as per external connections digital stop clock: portable with start / stop & reset operation set of necessary 4 mm spring loaded patch cords for interconnections detailed instruction manual supply to be connected: 230v, 1phase, 50 hz, ac mains, experimental set-up for calibration of a 3-phase watt hour meter with following specifications: to adjust & calibrate a three-phase energy meter by direct loading method to adjust & calibrate a three-phase energy meter by comparing with a sub-standard meterspecifications:static energy meter three phase: under test (local) duly mounted, wired and terminatedstatic energy meter three phase: sub-standard meter (isi mark) duly mounted, wired and terminatedvoltmeter: moving iron ac portable of class 1.0 accuracy and range 0 - 300 v acammeter: moving iron ac portable of class 1.0 accuracy and range 0 - 10 a acwattmeter:
Tender For corrigendum : carrying out various instrumentation works for part a as per standard specification by providing all required materials in connection with the composite works for setting up of hpg-2, butene-1 and psa units at lepetkata, assam of m/s bcpl-instrumentation"pressure gauges and accessories (excl. supply of impulse pipe / tubing materials)"installation of line mounted or remote mounted or local gauge board mounted pressure gauge/ pressure gauge with pulsation dampener / syphon / over-range protector (direct / surface mounted / diaphragm seal type) inclusive of mounting of instrument, supply and erection of supports / tray, mounting on support (if support required), laying of capillary on tray, fabrication and installation of manifolds / impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of supply of instrument, gauge board, yoke, piping material and calibration.in stainless steel as per standard 7-52-0432/1112in carbon steel as per standard 7-52-0432/1112in carbon steel as per standard 7-52-1222in carbon steel as per standard 7-52-1210in carbon steel as per standard 7-52-0433/1113in carbon steel as per standard 7-52-1120in carbon steel as per standard 7-52-0459/1158"pressure instruments (excl. supply impulse pipe / tubing materials)"installation of pressuretransmitters/ pressure switches (with or without pulsation dampener, over-range protector)/ diaphragm seal type pressuretransmitters/ diaphragm seal type pressure switches including mounting on yoke/ surface, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of supply of instrument, piping/tubing materials, all electrical/ pneumatic connections, yoke and calibration.in carbon steel as per standard 7-52-0437/0438/1131/1132in carbon steel as per standard 7-52-1222in carbon steel as per standard 7-52-1223in carbon steel as per standard 7-52-2103in stainless steel as per standard 7-52-1223in carbon steel as per standard 7-52-1143in stainless steel as per standard 7-52-1143"differential pressure instruments (excl. supply of impulse pipe/tubing materials)"installation of differential pressuretransmitters (including one side capillary type)/ differential pressure switch(including one side capillary type)/ diaphragm seal type dp transmitters/ diaphragm seal type dp switch including mounting on yoke/ surface, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of supply of instrument, piping material, all electrical/ pneumatic connections, yoke and calibration.in carbon steel as per standard 7-52-0452/1171in carbon steel as per standard b348-7-52-4062in stainless steel as per standard b348-7-52-4062in carbon steel as per standard b348-7-52-4063"differential pressure (flow) transmitters (excl. supply of impulse pipe/tubing material)"installation of differential pressure(with or without integral manifold)/ diaphragm seal type differential pressure flow instruments including mounting on yoke, supply of supports for impulse lines/ manifolds/ capillary, fabrication and installation of manifolds/ impulse lines with supports as per standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of supply of instruments, piping material, all electrical/ pneumatic connections, yoke and calibration.in carbon steel as per standard b348-7-52-3339in carbon steel as per standard 7-52-1305in stainless
Tender For bid to ras corrigendum : supply of digital milliohmeter , thermometer , ramp tester , insulation tester , true rms dmm , dc volt meter , dc ampmeter , digital multimeter , digital insulation tester , pressure tester gauge , suction gauge , dps450 air data test set , altimeter , air speed indicator , vertical speed indicator , dc volt meter , dc ammeter , ac volt meter , ac ammeter , thermo hygrometer , stop watch , torque screw driver , micro ohm meter , dc power supply , multimeter fluke , alpha battery charger concord , battery discharger concord , torque wrench , hygrometer
Tender For supply of fs make spares for elliot air compressor instrument - v diff pressuretransmitter, rtd,platinum, elliot make lp air compr, cable, vibration extension, transmitter, pressure (, transmitter, pressure, transmitter, diff press, current to pneumatic, compressoe reciprocating, switch,pressure, elliot make lp air compr. s, "controllers, electronic, transducer, pressur
Tender For supply of cordless digital micro ohm meter to measure resistance range 2 milli ohms - 20 kilo ohms of model no: lr 2065 of m/s. motwane make or its equivalent in makes: megger/fluke/rishab /metravi 7272a/kusam meco only as per specifications attached in annexure-a