Tender For supply of repair for thin film oven , back of unit cooling fan change , air inlet or input filter change , power inlet module change , carousel change , jar holder change , air oriface , airline plumbing , tray change , heaters located under tray change , heat control air regulator line filter change , service charge
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - coal mines; erection of 440v & 220v lt line for reorganization of power supply at dd unit of rocp; service provider
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 1 supply and installation of 37kw braking unit and dbr resistor suitable for 37kw vfd drive in the eot crane main hoist panel as per specifications ..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 2 installation of 37kw vfd drive for main hoist in eot crane and necessary interface power cabling and control cabling between vfd and braking unit ..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 3 supply of 5point5kw normal duty vfd for long travel operation of eot crane; as per tender document,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 4 installation of 5point5kw normal duty vfd for long travel operation of eot crane; as per tender document,repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; sl no 5 se
Tender For supply of repair and replacement ds 2cd 1043 g0e bullet camara 4 m 3 pint 6 mm 30 mtra ir distance , power supply 12v for cctv , d link camera cable , sharp dx 2500n tonner , replacement of developer and below parts sharp dx 2500 n , replacement of drum unit , replacement of cleaning blade , replacement of heat roller , replacement of bottom troller , replacement of fusing pressure roller , installation and service charges
Tender For tender for supply of sa of hose stg box , pump assy fuel , major kit clutch master cyl repair , mirrror assy out rear view rh , assy brake master cyl 31.8 75 strokes , axual roller brg , brake shoe externally actuated , assy bke shoe , solenoid switch , air fan insert wabco 4324100202 , drum clutch power-take off , gauge tyre pressure master type 70kpa to , first aid kit , v belt 1280 mm long , relay solid state , indicator light , filter element fluid pressure , strainer fuel , master cylinder repair kit bi , front direction indicator lh , ignition relay alt f7819400 f8355000 , regulator engine generator , pump fuel transfer , filter element primary , master cylinder repair kit api consisti , assy drive shaft 6.58 ratio thrust brg , ring spanner 18 19 metric , assy auxiliary water tank , pump fuel metering distributing , element oil filter , ring spanner 21 23 metric , funnel oil 152mm oval , regulator assy rh , harness assy wiring no 1 , dual brake valve , allen key set 02 to 06mm set of pices , relay assy , nipple grease conical head angled 1 4 an , front wind shild lh , oil seal , bulb 24v-5w su 85 cap , filter insert stage i , repair kit for accesories wiper , cord set high tension , lamp unit vehicular , rear view mirror , assy clutch master cylinder , halogen lamp 24v 75 70 w , bulb 12v 5w , hose 1 id 80 long
Tender For corrigendum : providing of repair and overhauling service - uninterruptible power supply (ups); ground power unit bison avish; yes; service provider premises
Tender For supply of assy vaccume hose for egr , assy pipe coolant bypass , assy vaccume hose for tc , repair kit , seal crank shaft rear oil , control valve , cable assy control , starter motor , master cyl power unit with container , fan belt , clutch disc 228 dia , hydraulic pipe , high pressure hose
Tender For tender for supply of ht cable -m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the sam