Web Analytics Made Easy - StatCounter

Transwitch Machine Repair Tenders

Get complete information related to latest Transwitch Machine Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Transwitch Machine Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Transwitch Machine Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42948038 Due date: 26 Dec, 202526 Dec, 2025 NA
Tender For bid to ras providing of repair and overhauling service - repair of ground power unit (dc gpu); repair of ground power unit (dc gpu); yes; buyer premises

Central Government/Public Sector

CTN :43254505 Due date: 09 Jan, 202609 Jan, 2026 2.33 Crore
Tender For supply of sitc of surveillance cctv system at central radio stores depot new delhi 03 d d - outdoor colour dome ptz camera , indoor fixed colour dome camera , varifocal outdoor fixed ir colour bullet camera , l2 switch , l2 switch industrial grade , 1g sfp module , rack mountable vms server , rack mountable analytics server , rack mountable nas server -140 tb , 8 port kvm switch , 65 inches led display , 43 inches display , workstation including operating system , cctv console , speed dome controller joystick , vms software and required camera connection license , frs or anpr software with camera license , vms client viewing license , cctv 19 inches equipment rack 42 u , cctv 19 inches weatherproof equipment rack 9 u , 25 mm dia pvc conduit , supply of armoured optic fibre communication cable , laying of armoured optic fibre communication cable , supply of 40 mm dia hdpe pipe , laying of 40 mm dia hdpe pipe on surface or recess or concelaed , laying of 40 mm dia hdpe pipe direct in ground , supplying and drawing of 1 run of utp 4 pair cat 6 lan cable , supplying and drawing of 2 run of utp 4 pair cat 6 lan cable , supplying and drawing of 3 run of utp 4 pair cat 6 lan cable , hot dipped galvanised iron cable tray 100 mm width x 50 mm depth x 1.6 mm thickness , powder coating m.s. cable tray bends 100 mm width x 50 mm depth x 1.6 mm thickness , 1.1kv grade, power cable of 3 core 1.5 sq mm , laying and fixing of upto 35 sq. mm clamped with 1mm thick saddle , laying of upto 35 sq mm in ground , rj45 io faceplate with gang box or backbox , 6 port light guide interconnect unit liu , sc lc fiber patch cord-3 mtrs , 15 kva online ups , low impedance digital grounding system 240ka , 24 ports rj45 patch panel with itegrated surge protection , rj45 surge arrestor of class d , 20 mm ms flexible pipe with pvc coating , excavation of the cable trenches in hard rock , 25mm x 5mm copper strip from earth electrode , copper bonded rod with low carbon steel , 6.0 metre hot dip galvanised octagonal pole , installation, integration, testing and commissioning of the complete system //bid details 2 / 37

CTN :43225953 Due date: 07 Jan, 202607 Jan, 2026 5.00 Lacs
Tender For supply installation and commissioning of lab. equipment for civil engg dept - digital compression testing machine with capacity of 3000kn (300 tons) with flexural attachment of 100kn capacity including accessories and toolkitspecification:-1. machine capacity required : - digital compression testing machine with capacity of 3000kn (300 tons) with flexural attachment of 100kn capacity. digital compression testing machine shall confirm is 516 and is 14858. digital compression testing machine for testing concrete cubes of size 100mm, 150mm, 200mm ,300mm and concrete cylinder specimen up to 300mm diameter and 300mm height . also the cement mortar cubes of 70.7 mm size and 50mm size. 2. loading frame:- steel welded loading frame with top cross head base and solid side walls. hydraulic piston is fixed to the base and platens are hardened, ground and polished. the upper and lower plate should be marked with the guidelines on the lower plate to keep the specimen co-axially with hydraulic jack. the machine should be provided with suitable side spacers as standard to accommodate the variety of sizes of specimens as indicated above. the two speed pump to allow fast approach of platens for daylight closure and also to allow precise control over load application using control lever and valves.3. digital display:- display shall show force and stress values in si units. the electronic control unit shall be based on suitable processor with a built in interface for laptop and computers. the processor speed shall be such that the online load deformation curve on full screen is smooth.4. the storage capacity to record and store 2000 complete test results with the facility of printing results/logged data through built in parallel port. least count of 0.1 kn.5. automatic controls for switch off on overload or over travel or specimen break or manual termination.6. power supply :- suitable for operation on 220v/230v single phase 50hz ac supply 7. additional requirements maximum clearance between plate 400mm. maximum distance between side platen 400 mm platen size 320mm square.8. flexure attachment:- flexure testing machine of 10 tons ( 100kn) capacity confirming to is 516. loading to be applied by the downward movement of piston. machine shall be suitable to test beams of 100x100x500 mm and 150x150x700mm.machine shall be supplied with suitable standard spacers for testing different sizes of beams.9. additional requirement for flexural test: three point loading light weight rugged high strength frame.least count 0.1 kndistance between supporting rollers: - 600mm for 150x150 x700 mm beam and 400mm for 100x100x500 mm beamdistance between loading rollers 200mm for 150x150x700mm beam 133 mm for 100 x 100 x500 mm beam power supply suitable for operation 220v 50hz single phase.10. the machine should be supplied with accurate toolkit11. compatible software should be included

CTN :43225472 Due date: 03 Jan, 202603 Jan, 2026 NA
Tender For providing of repair and overhauling service - unit ground power; unit ground power; yes; buyer premises

CTN :43225495 Due date: 03 Jan, 202603 Jan, 2026 NA
Tender For providing of repair and overhauling service - ground power unit; ground power unit; yes; buyer premises

CTN :43205945 Due date: 06 Jan, 202606 Jan, 2026 NA
Tender For tender for supply of make- ird mechanalysis limited , ird544m - vibration sensor , inductive velocity , top exit , mil 2-pin connector , 42.52mv/mm/s , 10 hz - 1 khz sku - m97120 , make- ird mechanalysis limited , stud for vibration sensor item no 1 , mounting/grub screws , 1/4 inch-28unf male , m6 x 1 male sku - stud-m6 provides connection between vibration sensor and mounting pad , m/s ird mechanalysis limited , vibration sensor mounting pad mild steel blackodized for ird544m (60x60x16 mm) with m6 thread for item no 1 tapped sku - ms-pad-ird544m , make- m/s ird mechanalysis limited , vibration sensor cable assembly for item no 1 , signal cable teflon 3.5mm dia , ss conduit 5mm id , 15 meter length straight , 2 pin ms , shielded , spade lugs at free end sku - m601015spade lugs at free end carry following colour code- red core- signal live , black core- signal ground , green core- signal shield , make- ird mechanalysis limited , eddy current pickup set comprising of probe , driver and connecting cable for 9 meter system. constituents. , make- m/s ird mechanalysis limited ird8800 rack , 8 position , 5u sku - m88008 this is the bin and will accomodate ird8800 cards , make- ird mechanalysis limited ird8800 (8800) , m88250 (88250) casing vibration module , 2ch velometer input (mv /mm/sec) and 1ch key phasor input , api standard 670 compliant sku - m88250-dc ird8800 series module m88250 can work with all types of velocity output vibration sensors that provide mv/mm/sec output - like ird531 (4 mv/mm/sec) and ird544m (42.52 mv/mm /sec) , make- m/s ird mechanalysis limited , ird8800 (8800) , m88900 (88900) - speed module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88900-dc , input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcp-ip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , ird8800 (8800) , m88600 (88600) - eccentricity module , 2ch eddy current pickup input , api standard 670 compliant , input- 24 v dc , sku - m88600-dc input- accelerometer and/or velometer , outputs-4-20 ma dc output proportional to full scale vibration rs-485 modbus rtu/tcpip output buffered output alarm relay contacts trip relay contacts full scale , alarm , trip , units , sensitivity and other parameters are programmable and password protected , make- ird mechanalysis limited , 35 mm din rail mount industrial grade power supply , 480 w , product- rps480 , 24 v dc output , dimension- 60 x 154 x 158.55 mm (w x h x d) , weight- 1050 gms , sku - rps480-24-ce supports 90 - 264 vac / 127 - 370 vdc power factor more than 0.95 full load over entire input range protection against short circuit , overload , overvoltage & over temperature cooling by free air convection ul 508 approved (e522848) efficiencies up to 93 % dc ok relay contact , make- ird mechanalysis limited , cabinet 1500 x 600 x 600 in mm , ip32 sku - cabinet-1500-600-600-ip32 , installation commissioning and calibration check of all supply sensor with unit at site

CTN :43148529 Due date: 02 Jan, 202602 Jan, 2026 NA
Tender For providing of repair and overhauling service - 90 kva mak gpu (ground power unit); na; yes; buyer premises

CTN :43092814 Due date: 13 Jan, 202613 Jan, 2026 NA
Tender For procurement of emergency breakdown van for ohe with full t&p equipment required for maintenance of ohe in the project of vr-drd & pnvl-kjt. - integrated testing equipment system with vanfor tss & ssp as per specification attached in annexure -i, fully automatic cable fault locating system annexure - ii, individual testing equipments as per annexure-iii3.1 thermal imager hand held camera as per specification (640 x 480), individual testing equipments as per annexure-iii3.2 power quality analyser with clamp set, individual testing equipments as per annexure-iii3.3 battery load unit, individual testing equipments as per annexure-iii3.4 third harmonics leakage current monitoring, individual testing equipments as per annexure-iii3.5 digital earth tester stake less & stake measurement, individual testing equipments as per annexure-iii3.6 automatic oil tan delta, individual testing equipments as per annexure-iii3.7 cable identifier, individual testing equipments as per annexure-iii3.8 sf6 gas analyser, individual testing equipments as per annexure-iii3.9 3 phase relay test set toolbox for substation, individual testing equipments as per annexure-iii3.10 battery ground fault tracer, individual testing equipments as per annexure-iii3.11 primary current injection test system for 2000a, individual testing equipments as per annexure-iii3.12 circuit breaker analyser

Central Government/Public Sector

CTN :43070262 Due date: 26 Dec, 202526 Dec, 2025 45.01 Lacs
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2); contract for network arc of trombay unit- 1 12 core single mode outdoor fibre optic cable of 9/125 micron specification, make:, link/ digilink/ molex/ tyco /amp/ systimax/ r&m/ panduit/ rit or equivalent, mtr 3000, 2 24 core single mode outdoor fibre optic cable of 9/125 micron specification, make:, link/ digilink/ molex/ tyco /amp/ systimax/ r&m/ panduit/ rit or equivalent, no 2000, 3 lc-sc single mode 9/125 duplex fibre patch cord of minimum 2 meter length, make:, dlink/ digilink/molex/tyco/amp/systimax/r&m/panduit or equivalent, no 50, 4 utp cat 5e cable ( 300 meter box), make: dlink/ digilink/ tyco/ amp/ systimax/, r&m/panduit/rit or equivalent, no 70, 5 modular type cat 5e wall mount information outlet with one rj 45 port and box,, make: dlink/digilink/tyco/ amp/systimax/ r&m/ panduit /rit or equivalent, no 1000, 6 cat 5e rj 45 jacks (1 box of 100 nos. connectors), make: dlink/digilink /molex/tyco, /amp/ systimax/ r&m/ panduit/rit or equivalent, no 50, 7 utp cat 6 cable ( 300 meter box), make: dlink/digilink /molex/tyco /amp /systimax/, r&m/panduit/rit or equivalent, no 20, 8 1 inch pvc casing caping 1 conduit, t -joint accessories, couplers etc. for fixing, isi, make, mtr 1000, 9 6 u wall mount rack with fans & power adapter strip, front & both side door, openings, make: valrack/netrack/srlink or equivalent, no 10, 10 9 u wall mount rack with fans & power adapter strip, front & both side door, openings, make: valrack/netrack/srlink or equivalent, no 10, 11 outdoor water proof underground enclosure box for ofc splicing of 24 core splicing,, make: raycaum / mx or equivalent, no 100, 12 wifi extender repeater signal booster, 300mbps make: dlink or equivalent no 20, sr item description in supply uom estimated, qty, 13 underground digging 2 feet deep in soft soil, backfilling for restoration to original, state, mtr 4000, 14 underground digging 2 feet deep in hard soil, & backfilling for restoration to original, state, mtr 1000, 15 underground digging 2 feet deep in tar road & backfilling for restoration to original, state, mtr 500, 16 underground digging 2 feet deep in concrete & backfilling for restoration to original, state, mtr 500, 17 pulling of fo cables inside duct and laying in underground trench mtr 5000, 18 pulling of fo cables inside casing caping / conduits and saddling inside building mtr 3000, 19 pulling of utp cables inside duct and laying in underground trench mtr 2000, 20 pulling of utp cables inside casing caping / conduits and saddling inside building mtr 15000, 21 pulling of fo cables / utp cables inside duct and laying on existing cable tray of 15, feet hight from ground using scaffolding / articulate booms, mtr 3000, 22 termination of utp cat 5/6 cable in rj45 information outlet (i/o) / jacks, fixing of i/o, box on wall, no 2000, 23 otdr testing for fo cable core no 1000, 24 splicing of sm / mm fo cable cores in liu / enclosure box & dressing no 5000, 25 installation / mounting of 6u / 9u rack on wall no 25, 26 one no onsite manpower qtr 12.

corporations/Associations/Others

CTN :43079475 Due date: 26 Dec, 202526 Dec, 2025 NA
Tender For auction sale of ground power unit
 Loading, Please wait...

Connect us via What's Up