Get complete information related to latest Trocar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Trocar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Trocar Tenders.
Tender For providing orthopedic implants at guru gobindsingh government hospital, jamnagar (part-2) - anatomically precontoured radial head rim plates (2.4 mm), titanium, left and right 2,3 and 4 holes, each, 245, locking screw for above plate ,titanium, each, 249, 2.7 mm titanium locking screws for above plate, each, 253, 2.7 mm titanium locking screws for above plate, each, 257, 2.7 mm titanium locking screws for above plate, each, 261, metacarpal plates various lengths, titanium, each, 265, precontoured anatomical locking clavicle plate -4hole to 8hole ,titanium, each, 269, titanium clavicle anatomically precontoured plate compatible with 2.7/3.5mm lhs, with extension, k wire hole for 1.6mm, left and right, various sizes, each, 273, titanium k wire, trocar tip, 6 inches 1.6mm diameter for above plate., each, 277, 3.5 mm titanium locking screws for above plate, each, 281, dog bone button system for fixation of ac joint disruption with instrumentation set., each, 285, 4.5mm cortical screw for above plate, each,
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For tender for supply of daily report of record clerk , medical form for claiming refund for treatment in hospital , medical form for claiming for treatment by ama , medical form certificate a , medical form certificate b , apar for group b officers , test letter , diary of overseer
Tender For corrigendum : purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopa
Tender For supply of radiological items at faamch, barpeta for the financial year 2026-27 - barium microbar (liquid), barium sulphate, mri dry view dve laser imaging film, size- 14" x 17", 5952 laser imager, chest stand (floor type), developer (13.5 lt), digital x-ray film, size : 8 x 10 , make : agfa, digital x-ray film, size : 10 x 12 , make : agfa, digital x-ray film, size : 14 x 17 , make : agfa, digital x-ray film, size : 8 x 10 , make : fuji, digital x-ray film, size : 10 x 12 , make : fuji, digital x-ray film, size : 14 x 17 , make : fuji, dry laser imaging films (carestream) dve 8" x 10", dry laser imaging films (carestream) dve 10" x 12", dry laser imaging film (konica minolta) drypro trs 8 x 10 , dry laser imaging film (konica minolta) drypro trs 10 x 12 , dry laser imaging film (konica minolta) drypro trs 14 x 17 , fixer (13.5 lt), hanger (size- 10 x 12), hanger (size- 12 x 12), hanger (size- 15 x 12), kg-4 screen fitted in kiran cassette (size- 10 x 12) 400 speed, kg-4 screen fitted in kiran cassette (size- 12 x 12) 400 speed, kg-4 screen fitted in kiran cassette (size- 12 x 15) 400 speed, kg-4 screen fitted in kiran cassette (size- 6.5 x 8.5) 400 speed, kg-4 screen fitted in kiran cassette (size- 8 x 10) 400 speed, lead barrier (6 x 3) on costar wheels, lead goggler, lead grid, lead hand gloves, lead letter (a-z), lead letter (r-l), lead neck tie, lead number (0 to 9), lead screen (folded), microbar suspension (1 ltr), screen for cassette (size - 8 x 10), screen for cassette (size - 10 x 12), screen for cassette (size -12 x 12), screen for cassette (size - 12 x 15), tissue roll (standard size), thermal printing roll, thyroid shield, usg gel (5 ltr jar), usg gel (250 ml. tube), x-ray clip, x-ray film (size- 10 x 12) [green], x-ray film (size- 12 x 12) [green], x-ray film (size- 12 x 15) [green], x-ray film (size- 8 x 10) [green], x-ray film (size- 8 x 6) [green], x-ray film dryer, x-ray lead blocker (divider) size- 7 x 17, scalp vein set, size : 20g, scalp vein set, size : 22g, automatic biopsy gun, size : 14 gz, automatic biopsy gun, size : 16 gz, automatic biopsy gun, size : 18 gz, automatic biopsy gun, size : 20 gz, automatic biopsy gun, size : 22 gz, semi automatic biopsy gun with coaxial (msk)gun size : 18g, 16cm, coaxial size : 17g, 13.8 cm (1x5)(specification : usfda approved, two penetration depth in a single gun (10mm, 20mm), option of blunt tip and trocar tip stylet in the package, depth stopper with colour code), for salient and vistron plus ct scan injector : 150cmextension tube single 2068kpa, 300 psi, 190ml syringe with quick fill tube (qft) 2068kpa, 300 psi, for salient dual head ct scan injector : 150cm y extension tube dual check valve 2068kpa, psi, 190ml syringe with quick fill tube (qft) 2068kpa, 300 psi, for mri injector : medrad sprectis solaries mri integral 1 with check valve 1- connector tube
Tender For selection of an agency for operating and managing 35 smart mobile medical units (mmu) and preventive health checkup follow-up and treatment in all the districts of karnataka for the registered construction workers and their dependents of karnataka building and other construction workers welfare board.