Get complete information related to latest Tube Chock Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tube Chock Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tube Chock Tenders.
Tender For supply of kit for satisfactory suitable operation under the attached annexure - the equipment should be microprocessor based fully automatic with preprogrammed internationalstandards to measure oil breakdown voltage on insulating oils used in electrical equipments like transformer,ct, circuit breaker, capacitors & other electrical equipments.
Tender For supply of repair and painting of volleyball court boundary wall 96x68x3 ft , repair of iron mesh fencing 10 x35 ft for 02 panels , 200 w led flood light , 2sqmm multi strand copper wire , miniature circuit breaker , on or off switch , 12 module surface box and plate , installation charges for electrical fitting and accessories
Tender For supply of c and s make air circuit breaker spares and associate electrical equipments - arcing contact assembly (set of 1 no. moving and 1 no. fixed) for ah-10d-cs-3p, make:c&s, acb product code: arccont-10d, main moving contact assebly of ah-10d-cs-3p air circuit breaker catlog ref: movmain-10d, make:c&s, main fixed contacts(upper terminals) of ah-10d-cs-3p air circuit breaker catlog ref: fixcont-10d, make:c&s, lower mechanism for 800a acb of ah-8d-cs-3p, cat ref:lower mech6-16d, make:c&s, spring charge motor 220v ac/dc, type:, umg-27 for acb, model:ah-40d-cs-3p, make: c&s, front cover for acb, model:ah-8d-cs, make: c&s, closing coil assembly for acb,model:ah-40d-cs-3p, 220v dc, make: c&s, tripping coil assembly for acb, model:ah-40d-cs-3p, 220v dc, make: c&s, thermal over load relay, contactor mounting, current setting range: 48-57a,cat ref: lr1-d63359, make:c&s, lamp,indication;type:led;voltage:220vdc;color:blue;model:rb2-bvl76- 220; additional information:assembly unit, make:c&s, lamp,indication;type:led;voltage:220vdc;color:green;model:rb2-bvl73-220; additional information:assembly unit, make:c&s, lamp,indication;type:led;voltage:220vdc;color:orange,amber;model:rb2-bvl75-220; additional information:assembly unit, make:c&s, lamp,indication;type:led;voltage:220vdc;color:red;model:rb2-bvl74-220; additional information:assembly unit, make:c&s, lamp,indication;type:led;voltage:220vdc;color:yellow;model:rb2-bvl75-220; additional information:assembly unit, make:c&s
Tender For installation of 10 mva transformer with necessary busbar arrangement with foundation and structural arrangement for fixing of circuit breaker and allied electrical items at 33 kv main sub station akkocp , bnk area.
Tender For corrigendum : replacement of 220kv circuit breaker of 160mva ptr-i hv at 220/132kv minpur ss in onm,400kv narsapur division (electrical and civil portion)
Tender For supply of electrical consumable and other miscellanous items miniature circuit breaker 2 pole 16 amp, 240/415v single phase ac, 50 hz. , miniture circuit breaker mcb 32 amp, 2 pole, 10 ka, 240/415 volt ac , miniature circuit breaker 3 - pole, 32 a, 415 v , m.c.b.isi markd 32a, 415v ac 4 pole , m.c.b.isi markd 63a, 240/415v 4 pole , switch socket combined 6 & 16 amp.anchor make , plug socket 6 amp 230v,5 hole , ring type insulated copper terminal ends (lugs) for 2.5 sqmm cable, stud hole 5.2 mm , 2.5 sqmm crimping type , red oxide , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm , width x 7.5 mtr length x 0.125 mm thickness, of red colour , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm , width x 7.5 mtr length x 0.125 mm thickness, of yellow colour , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm , width x 7.5 mtr length x 0.125 mm thickness, of blue colour , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm. , width x 7.5 mtr length x 0.125 mm thickness. of black colour , self adhesive pvc electric insulation tape rolls with isi mark size 1.80 cm , width x 7.5 mtr length x 0.125 mm thickness. of green colour , oil stop leak putty 114 gms. pack , led down/panel light 20 watt, square white color 240 volt
Tender For corrigendum : aoh of electrical equipment and auxiliaries of sstpp unit-1 of 2x600mw, sstpp, mppgcl, khandwa. - generator, misc works in generator overhauling, h2 purging after unit shutdown & h2 refilling before of unit light up., transformers, general overhauling of ht transformers, generating transformer(work description as detailed intender schedule), station transformer (work description as detailed intender schedule), inter-connecting transformer (work description as detailed intender schedule), unit auxiliary transformer (work description as detailed intender schedule), neutral grounding panel ( gen., gt, st, uats) {(work description as detailed intender schedule)}, general overhauling of lt transformers, lt dry type transformers (work description as detailed intender schedule), lt oil filled transformers (work description as detailed intender schedule), switchyard, breaker, isolators ,earth switch, bay equipments (cleaning & terminal tightness), bus ducts (work description as detailed intender schedule), 21/ 15.75 kv gen bus duct, 11 kv uat/st bus duct, 6.6 kv uat/st bus duct, lt transformer bus duct, esp, ltmsb & acp buses , ec panels & heater work (as per scope of work), ltmsb & acp breakers (as per scope of work), ltmsb & acp modules(as per scope of work)eerm=80 , cerm=80, gdrm=8, fields= 80, vfd supply=4, lighting supply & etc. = 25(approx), ht switchgear (11 kv/ 6.6 kv), bus cleaning , tightness & complete inspection of all buses., breaker cleaning, tightness & operation checking, bop switchgears panel / local control panels / wall mounted panels and 415v lt swbd/ mcc/acdb/dcdb switchgear panel, bus cleaning , tightness & complete inspection of all buses. breaker cleaning, tightness & operation checking, power house lighting & power supply, cleaning , tightness & complete inspection of all lightning transformers & ldb, providing power supply as per site requirement & for other maintenance work of bmd,tmd etc., ht motors, servicing of ht motors, ht motor cooler (general inspection & cleaning), lt motors servicing, motors above 40 kw, motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, esp lt motors 1 kw and below, lt motor overhauling, motors above 40 kw(machining), motor 40 kw to 11 kw, motors 10 kw to 5.5 kw, motors 5 kw to 1.1 kw, motors 1 kw and below, servicing of dc bus, cleaning/servicing of 220 v dcdb buses & modules, servicing of soot blowers, servicing of soot blower motor 1 kw & below, servicing of soot blower panel/modules
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard three phase manual isolators (ds) preventative maintenance (total quantity 1 is equal to 19 numbers ..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, 220kv switchyard three phase motorized isolators (ds) preventative maintenance (total quantity 1 is equal to 17 numbe..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance in preventative maintenance of three phase 220kv sf6 circuit breaker (total quantity 1 is equal to 10 numb..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - rr site 1 and 2; electrical system or installation, assistance in preventative maintenance of 220 / 132 kv three phase mocb (total quantity 1 is equal to 2 numbers for t..,repair, main