Get complete information related to latest Tube Light Starter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tube Light Starter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tube Light Starter Tenders.
Tender For providing and fitting of essential items and allied material for snow clearance operation at nathatop sanasar road - supply, testing and commissioning of 48v smps float cum boost automotive battery charger with moveable trolley stand for snow operation at nathatop - sanasar roadgeneral technical requirements for battery charger suitable for 48v vrla type battery1.) type -float & float cum boost charger for vrla type, full wave, full controlled type. 2. ) ratings- 15 a float cum boost for 48v, 150 ah vrla type battery 3. ) ac input- i) voltage 415 vac 10%ii) frequency 50hz 5% iii) phase 3 - phase 4.) d.c.output voltage settings -nominal float fc 48/54.5v (adj. by + 20%, - 5% bc 48/66.5v (adj. by + 2%, - 5%) 5.) output current limit 15a 15a 6. ) power conversion ac to dc by means of three phase full wave, half controlled bridge rectifier consisting of thyristors and diodes. 7.) voltage regulation at bridge output. + 1% of set value for + 10% input voltage variations, 0-100% load variation. 8. ripple voltage less than 3% rms without battery connected. 9. efficiency more than 80% at full load 10. protections (a) input side ac input mccb & elbs with input on/off switch and fuses, contactor (b) output side dc output mccb with output on/off switch and fuses. (c) protection current limit protection, soft start feature, surge suppressor. fast semiconductor fuses for rectifier bridge. (d) control circuit fuses (e) capacitor circuit rectifier hrc fuses. (f) over-voltage cut-back (g) charger over load / short circuit (h) blocking diode 11. controls and switches followings controls and switches are provided in the system 1 ac input source mccbs with interlocking 2 dc output mccb 3 auto/manual float/boost mode selector switch. 4 float and boost voltage variable potentiometers. 5 manual voltage adjustment potentiometer 6 test push button 7 reset push button 8 battery current adjustment potentiometers 9 heater s power supply switch 12. features the following features are provided in the systems: 10 soft start on dc side 11 class-f insulation for all magnetic 12 automatic voltage regulation. 13 automatic changeover from float to boost and vice versa based on current, drawn by battery. 14 filter circuit to eliminate ripple. 15 charger current limit 16 separate battery path current limit. 17 built-in auto phase reversal of operation. 13. meters f.c. b.c. (i)input voltmeter (i) common (ii) input ammeter (ii) input ammeter (iii) output voltmeter (iii) output voltmeter (iv) output ammeter (iv) output ammeter. battery volt meter battery ammeter earth leakage ammeter 14. indications phase on lamps (ii) output on lamp a)phase on lamps (ii) output on lamp. (iii) charger on float led (iv)charger on boost led. 15. annunciation with audiovisual alarms. (i) ac input mains failure (ii) input phase failure (iii) ac under voltage iv) input phase failure v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped xiii) charger over load xiv) earth leakage xv) dc earth fault xvi) alarm supply fuse failure xvii)battery low condition. v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped. note : all the alarms shall be provided through electronic display cards. audio alarm through buzzer, visual indication through 10 mm leds & alarm ackn. / reset and led provision is through push buttons. 16. operating ambient temperature surrounding the panel 00 to 500 c 17. surrounding the panel relative humidity. 0-95% non-condensing 18. panel (i) protective grade (ii) cooling (iii)paint ip 42 natural air-cooled smoke grey of iss-692 shade a) average winding temperature rise over ambient temperature b) insulation class c) insulation breakdown voltage. as per relevant iss. f 3 kv for 1 min withstand. 19. cables 1100 v
Tender For supply of disconnector for sr, type lthmd 1500, 2poles no, control voltage 110v dc, auxiliary contacts 2 no +2nc, msi family code: lthm15012sa1101, msi part no. lthm15002001003, make : microelettrica scientifica/italy or similar. the contactor is to be modified type as per letter no. ncr 1872, qn 600748519 by microelettrica scientifica enclosed in annexure. note: firm should submit authorised dealership certificate along with tender.
Tender For corrigendum : supply of office equipments, furnitures: miscellaneous , television set , computer and hardware & ups accessories ,, blic addressing system , multimedia equipment & parts , access control system , cctv system , air brake contactor , cable-miscellaneous , public addressing syste
Tender For supply of siemens spares - power contcr 3tf5002oauo-coil volt230vac , main contact for 3tf50 110a contactor , aux.control contactors ge make coil sup , siemen control relay 3th80-22-oa 240v ac , contact 3tf51 140a 110v 3ty7- 510oyca , siemen contactor 240vac type 3tf5102 oau
Tender For bid to ras procurement of electrical spare - contactor siemens model 3th42 , contactor l and t model ml2 , batteries 12v 7ah , shielded cable 5 core 2 point 5 sq mm , shielded cable 5 core 1 point 5 sq mm , shielded cable 2 core 1 point 5 sq mm , control cable 2 core 1 point 5 sq mm heat proof cable