Get complete information related to latest Turbine Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Turbine Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Turbine Scrap Tenders.
Tender For providing and fitting of safety devices at various water supply schemes of jal shakti (phe) mechanical rural division srinagar - providing, installation, testing and commissioning of power supply monitoring device for the protection of motors of reputed make to be installed at various water supply schemes of rural sub-division srinagar. (rest technical specifications as per annexure"a"), providing and fitting of thermal overload relays of type mn with following features:. built-in single-phase protection. manual and auto reset mode. confirms is/iec 60947-4-1 & iec60947-4-1the job includes fixing of the relay to the system and includes the cost on account of all accessories required for carrying out the said job. once connected the system is to be tested on load., relay range 45-75 a, relay range 66-110 a
Tender For dc-dc converter for dispatcher of 3s02 thales afc gate used in thales 3s02 afc gat e dispatcher for power supply. 1. specifications- 24v dc to 12v dc converter module. 1.1 make-la mda/cosel. 1.2 model- lambda pp25-24-12, cosel zus252412, 1.3 input voltage-18v to 36v dc. 1.4 output voltage-12v dc, output current-2.1a,output power=25.2w. 1.5 single output dc convertor with ultra thin profile-h-8mm, l-65mm, w-50mm. 1.6 terminal assignments: 1.6.1 input: pin*1 +v, pin*2 -v , pin*3 cnt. 1.6.2 output: pin*4 +v, pin*5 -v, pin*6 trm. 1.7 case: copper (thickness 0.4m m). 1.8 operating temperature -20 to +71 degreec. 1.9 convection cooling, isolation between input and output, overload voltage & overload current protection. 1.10 warranty-minimum one year. note: - 2. actual size, dimensions and fitment of supplied item must be "compatible" with the existing th ales 3s02 afc gates of dmrc in all respects. 3. vendor is required to mandatorily demonstrate/ sa mple test of the proposed items within 10 days from the date of award of loa/po for the functionalit y & compatibility with the existing thales 3s02 afc gates. 4. vendor is to provide the datasheets of the proposed items clearly depicting the technical details such as given below at the time of bid sub mission for technical evaluation. 4.1 make & model of the offered item. 4.2 specifications/ part no. w .r.t. its of supplied item. 4.3 all technical specs as per point 1 above. 5. vendor is to provide the "spe cifications compliance certificate" on their company's official letterhead as part of bid submission. 6. the supplied material must be compatible with existing system of dmrc in all respects. ]
Tender For dc-dc converter for dispatcher of 3s02 thales afc gate used in thales 3s02 afc gat e dispatcher for power supply. 1. specifications- 24v dc to 12v dc converter module. 1.1 make-la mda/cosel. 1.2 model- lambda pp25-24-12, cosel zus252412, 1.3 input voltage-18v to 36v dc. 1.4 output voltage-12v dc, output current-2.1a,output power=25.2w. 1.5 single output dc convertor with ultra thin profile-h-8mm, l-65mm, w-50mm. 1.6 terminal assignments: 1.6.1 input: pin*1 +v, pin*2 -v , pin*3 cnt. 1.6.2 output: pin*4 +v, pin*5 -v, pin*6 trm. 1.7 case: copper (thickness 0.4m m). 1.8 operating temperature -20 to +71 degreec. 1.9 convection cooling, isolation between input and output, overload voltage & overload current protection. 1.10 warranty-minimum one year. note: - 2. actual size, dimensions and fitment of supplied item must be "compatible" with the existing th ales 3s02 afc gates of dmrc in all respects. 3. vendor is required to mandatorily demonstrate/ sa mple test of the proposed items within 10 days from the date of award of loa/po for the functionalit y & compatibility with the existing thales 3s02 afc gates. 4. vendor is to provide the datasheets of the proposed items clearly depicting the technical details such as given below at the time of bid sub mission for technical evaluation. 4.1 make & model of the offered item. 4.2 specifications/ part no. w .r.t. its of supplied item. 4.3 all technical specs as per point 1 above. 5. vendor is to provide the "spe cifications compliance certificate" on their company's official letterhead as part of bid submission. 6. the supplied material must be compatible with existing system of dmrc in all respects. ]
Tender For design, engineering, manufacture, quality surveillance, testing at suppliers works, transportation, supply on for destination basis, retrofit, erection, testing and commissioning of plant scada, distributed control system(dcs), control and protection system, metering, synchronizing for all units including supply, laying, testing, termination of cables and networking, communication of ewly supplied and existing system, dismantling of existing panels & cables, etc. for nagjhari, kadra, kodasalli and supa power houses of kpcl
Tender For supply of 25mva, onan, 33 kv/6.6kv power transformers with nitrogen injection fire protection system along-with their accessories and spares
Tender For augmentation of power supply system in n-s corridor,up gradation of negative isolators & dc negative cables in tunnel section from kdmi to kmuk, renovation of kmuk car shed,provision of ets and other related works in north south corridor, automatic short circuiting between 3rd rail and running rail, replacement of old isolator by motor operated isolator, replacement of overaged isolators of noapara depot & kkvs depot,unit protection of rectifier at dum dum tss, rabindra sarobar tss & park street tss, augmentation of power supply system at substations from kshy to kcen & provision of cctv in electrical substations of north south corridor in metro railway kolkata
Tender For corrigendum : supply of spares for co2 based generator fire protection system at power house of omkareshwar power station - lcd display fmz5000 320x240, fmz 5000 conventional detector module, fmz 5000 8 relay module, monitoring high pressure system loss (light barrier), zonal card (front panel fmz5000) bbf, co2 cylinder valve k-85-20, release device,e 24v-dc, note: 1) transit insurance shall be in the scope of the supplier.2) bidder should quote unit basic rate inclusive of packing, forwarding, handling and freight charges for f.o.r. omkareshwar power station in column no.5. 3) bidder shall quote unit cgst, sgst amount in column no. 6 &7 respectively for intra-state supply or shall quote igst amount in column no. 8 for inter-state supply. 4) bidders are requested to verify carefully the amount entered by them in respective column and the amount generated automatically through formulae before uploading it to the portal
Tender For corrigendum : augmentation of power supply system in n-s corridor,up gradation of negative isolators & dc negative cables in tunnel section from kdmi to kmuk, renovation of kmuk car shed,provision of ets and other related works in north south corridor, automatic short circuiting between 3rd rail and running rail, replacement of old isolator by motor operated isolator, replacement of overaged isolators of noapara depot & kkvs depot,unit protection of rectifier at dum dum tss, rabindra sarobar tss & park street tss, augmentation of power supply system at substations from kshy to kcen & provision of cctv in electrical substations of north south corridor in metro railway kolkata
Tender For procurement of spares of forbes marshall make vibration monitoring system of turbine and boiler auxiliaries for unit. no.5,500mw,at sgtps, - , "shaft vibration - extension cablemodel no: fw-202fl-40", "shaft vibration - drivermodel no: fk-202f-2-3-1", "bearing vibration along with mounting pad (piezo velocity sensor)model no: cv-861", "casing expansion driver, 3-wire lvdt signal conditionermodel no: vm-21p2-20-s-050-2", "dual path monitor, range 0-20 mm/smodel no: vm-5m-ld2111110-000-000-001-0db6f0158", "dual path monitor range 0-50 mm/smodel no: vm-5m-kd2114410-000-000-001-0db6f0161", "vibration calibration shaker kits for sensor cv-861model no: gjx-3", "mini power input supply: 100-240v ac output supply: 24v dcmodel no: mini-ps-100-240ac/24dc/2.5 or fm approved", "velocity-displacement channel selection module 8-channelmodel no: ul08tg-dpdt or fm approved", "ss conduit with pvc coating preferable high temperature anaconda conduit along with glands for protection of sensor wire (prices per meter) (fm approved)"birsinghpur