Get complete information related to latest Turbine Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Turbine Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Turbine Spares Tenders.
Tender For corrigendum : providing of calibration services - mechanical, electrical, as per technical specifications; frequency, power factor, phase angle, resistance, as per technical specifications; nabl labs; lab
Tender For corrigendum : providing of calibration services - electrical; frequency, power factor, phase angle, vibration test system qty-01; nabl labs; hybrid (detailed in scope of work)
Tender For corrigendum : construction of school building, staff quarters (type-ii/4 nos. (g plus 1), type-iii/4 nos. (g plus 1) and type-v/1 no. (s/s), boundary wall, etc. for kendriya vidyalaya bsf, khajuwala (raj.). (sh supply, installation, testing and commissioning of 3 phase shunt reactor for maintaning and rectifying the power factor)
Tender For supply of power factor controller, model- br 6000 r12, make- epcos or equivalent model in any other make , contactor for capacitor switching duty, suitable for 60 kvar capacitor, 220v, 50 hz, 1 n0+ 1nc, 3 pole- ac , contactor for capacitor switching duty, suitable for 22 kvar capacitor, 220v, 50 hz, 1no+ 1nc, 3 pole-ac , contactor for capacitor switching duty, suitable for 12.5 kvar capacitor, 220v, 50 hz, 1no+ 1nc, 3 pole-a
Tender For supply of solar insulation meter , pyranometer , pyrheliometer , lux meter lux meter lcd read out 005 to 7000 lumens with battery , magnetic flux meter 0500 tesla , tong tester clamp meter 0 100 a digital type , soldering iron set 25 watt 65 watt and 120 watt 230 volt set of 3 , temperature controlled soldering iron 50 watt 230 volt , thermometer digital 0 degree c 150 degree c , sun shine recorder , weather monitoring station to monitor and record unshine wind velocity temperature rainfall etc with software , solar cell based sunlight radiation meter for solar power measurement up to 2000 wsquare meter , magnetic compass , cut models of photo voltaic cell assembly , model of lead acid battery , lead acid battery set 12v 40ah 75ah , lead acid battery 12v 100 ah , solar simulator for solar cell characteristic study to study iv curve of a solar cell of minimum 2 watt under variable illumination temperature and suitable load , iv curve tester , sun path finder , solar energy trainer with grouping of solar cells to group series or parallel at least six solar cells each with minimum 2 w with suitable loads , solar tracker demonstrator kit to study manual and automatic control of 10 w solar panel in east west and northsouth andback , halogen lamp set with stand for illumination of solar panels in lab ac mains operated to provide 0 to 1000 watts per meter square , pedestal grinder double ended 300 mm , battery charger 0 6 9 12 24 48 v 30amp , solar photovoltaic module 10 w poly crystalline module , solar photovoltaic module 250 w , solar photovoltaic module 250 w thin film module , solar photovoltaic module 40 w poly crystalline module , solar photovoltaic module 5 w poly crystalline module , solar photovoltaic module 75 w amorphous silicon module , solar photovoltaic module 75 w mono crystalline module , solar panels 250 wp , solar charge controller with dusk to dawn automatic switching 12v 10a , solar charge controller with manual switch day lighting 12 v 10 a , array junction box for connecting 250w x 4 nos solar panel with dc fuse dc mcb and surge suppressor protection , solar lantern led type , solar lantern cfl type , solar lantern assembly sets , home light system 12 v dc with fm receiver led bulb and mobile charger as loads , solar cell kit , clinometer for angle measurement , spirit level for floor level check , anemometer for wind speed measurement , dc table fan 12 v , ac voltmeter mi 0 , providing and supplying of volt meter 0 30v , volt meter 0 100v , ammeter mc 0 1a , ammeter mc 0 5a , ammeter mc centre zero 0 20a , ammeter mc centre zero 050a , power factor meter , rheostat set 0 1 ohm 5 amp 0 10 ohm 5 amp 0 25 ohm 1 amp 0 300 ohm 1 amp set , ac energy meter single phase 10 a 240 v inductiontype , ac energy meter three phase 15 a 440 v induction type , kilo wattmeter analog , digital wattmeter 230 v 1 kw 50 hz , phase sequence indicator 3 phase 415 v , frequency meter 45 to 55 hz , dc led lamp set 3w 5w 10w set of 3 , dc pump 24 v , pwm controller , mppt charge controller , solar grid tied inverter demonstrator kit 300w kw
Tender For supply of led four feet tube light fitting 20/22 watts batten, housing : aluminum extrusion finish white powder coated , colour : cool white , diffuser milky white , 100 lumens/watts., temperature (k) : 6000+/-500 , beam angle (in degree) > / = 120 , operating voltage range (in volts) 160 to 270, rated voltage (in volts) 220 to 240 - 50hz , power factor > / = 0.9, surge voltage withstand (in kv) 2.5/4, cri > 80% . ip - 20/21. make: philips, wipro,havells, crompton, polycab, jaquar only. note: (1) oem proof of purchase to be submitted along with the material supplied. [ warranty period: 60 months after the date of delivery ]
Tender For corrigendum : supply of miniature circuit breaker (mcb) for power factor correction of compressors of lhb ac coaches having current rating 6a, voltage rating 415 vac,3 pole, breaking capacity 10 ka, curve d, confirming to rdso letter no. el/7.1.108/ mssbc dated 17.09.2021 item no. 46. material is legrand part no. 408758 or siemens part no. 5sl73068rc or abb part no. sb203 m-d6 or l&t part no. bb30060d or schneider part no. a9n3p06d.firm should submit certificate of authorization from oem & test report. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of miniature circuit breaker (mcb) for power factor correction of condenser & blower motor of lhb ac coaches having current rating 2.5/3a, voltage rating 415 vac, 3 pole, breaking capacity 10 ka, curve d, confirming to item no. 45 of bill of material of rdso letter no. el/7.1.108/ mssbc dated 17.09.2021.firm should submit certificate of authorization from oem & test report. [ warranty period: 30 months after the date of delivery ]