Web Analytics Made Easy - StatCounter

Tv Tuner Card Tenders

Get complete information related to latest Tv Tuner Card Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Tv Tuner Card Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Tv Tuner Card Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42007422 Due date: 09 Oct, 202509 Oct, 2025 NA
Tender For supply of 9 lines of cafs moto lp80 d d - cover front waris pref full , potentiometer volume , tact switch new type , speaker , lcd display module , flex universal connector , power supply unit for gm338 for base station , repeater exhaust fan , pref full front cover conv-epp

Central Government/Public Sector

CTN :42021886 Due date: 16 Oct, 202516 Oct, 2025 NA
Tender For supply of 12 v 10 a battery charger lcd display controller pcb board indoor unit and window ac unit : : - 12v 10a battery charger , controller of model kg 934 v2 , main detection lcd display controller , pcb board suitable for 2 ton split ac unit , pcb board suitable for 1 point 5 ton split ac unit

State Government

CTN :41676459 Due date: 07 Oct, 202507 Oct, 2025 NA
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20

Central Government / Public Sector

CTN :41854582 Due date: 03 Oct, 202503 Oct, 2025 7.31 Lacs
Tender For supply of electrical spare boq d d--thyristor module psthm 162 19 mcc 200 16 io1 , thyristor module psthm 200 16 mcc 312 18 io1 , tube light 20 w led , flameproof light 60 w led , braided copper wire 6 sq.mm , crocodile clip , flameproof safety torch , ceiling bldc motor fan , rccb 2 pole 30 ma 64 a , earthing cable 10 sq mm copper , copper strip 25 sq mm , sfu unit 63 a 3 pole with neutral , 1 core 1.5 sq mm pvc copper circular sheathed cable with rigid conductor , 1 core 1 sq mm pvc copper circular sheathed cable with rigid conductor , motor operator geared motor device of acb , undervoltage release uvr of acb , shunt trip coil , shunt closing coil , acb front cover new emax e3 3p , acb front cover new emax e3 4p , hrc fuse din 400a , hrc fuse base , soft- starter front keypad lcd display assembly with control card , hrc fuse din 250a , hrc fuse din 200a , hrc fuse din 63 a , hrc fuse din 80a , mcb 40a 2pole 240v

CTN :41800529 Due date: 04 Nov, 202504 Nov, 2025 NA
Tender For procurement of spares for mirage aircraft - distribution box, video acquisition module (atase ii), operators interface, frame front assembly, gnss board, crt assembly, equipped chassis, mdpu-serpam enclosure, power supply unit, lcd and light unit, interface source and amplifer, equipped main housing, c c a, clamp-guidance, plate (fuel pressurisation system), valve,filling, hbj-hv power supply, mic pcb, mdr wired structure, key board, power supply module, inertial frame, mks board, management video module, display head module, board assembly (ak and evs), mia pcb with software, box,storage, detector,landing
 Loading, Please wait...

Connect us via What's Up