Tender For tender for supply of visual inspection and photography performing a visual survey of the building and recording as per specification of docoments , ultrasonicpulsevelocitytest for rcc structure in accordance as per specification of docoments , rebound hammer test as per specification of docoments , core test as per specification of docoments , cover meter test as per specification of docoments , chemical test for rcc structure in accordance as per specification of docoments , half cell potential test for rcc structure in accordance as per specification of docoments , carbonation test for rcc structure in accordance as per specification of docoments , to check and confirm present as per specification of docoments , to provide recommendation for structure repairs a as per specification of docoments , vetting of report from iit mumbai after the site inspection and verrified by eng in charge
Tender For supply of visual inspection and photography performing a visual survey of the building and recording maping on drawing to assess extent of spelled concrete cracked concretehoney combing , ultrasonicpulsevelocitytest for rcc structure in accordance with is 516 part 5 2018 section 1 by portable ultrasonic non destructive digital test equipment , rebound hammer test rebound hammer test in accordance with is 516 part 5 2018 section 4 by portable rebound hammer equipment , core test core cutting and compression test for rcc structure in accordance with is 516 on rcc members 70 mm core cutting in reinforcement concrete core filling , reinforcement mapping reinforcement mapping test on rcc structure to assess covers spacing bars including approximate diameter , chemical test for rcc structure in accordance with is 456-2000 i determination of ph value ii determination of water soluble suphates iii determination of water soluble chlorides content , half cell potential test for rcc structure in accordance with is 516 part 5 2018 section 2 half cell potential to assess the probality of corrosion of reinforcement , carbonation test for rcc structure in accordance with is 516 part 5 2018 section 3 carbonation test to measure extent of carbonation from the concrete surface at strategic locations , to check confirm present status of structure on basis on ndt results visual inspection , to provide recommendation for structure repairs and technical specification preparing bill of quantities for the repair etc all as specified and directed , vetting of report from iit nit ) /bid number: gem/2026/b/7250722 * /dated: 20-02-2026 & & / bid document1 / 14
Tender For supply of fire training equipment d d -collecting breeching , dividing breeching , revolving head , hpt machine , safety testing cage for hpt machine , pick up tube , metal strainer , male to male adaptor , female to female adaptor , suction hose , trolley for storage and transportation ba cylinders