Tender For corrigendum : supply of gastroenterology consumables - endoscopic stearable sphincterotome center guidewire lumen , endoscopic stearable sphincterotome 4.9fr tip size , eus needle 22g for eus-guided sampling , eus needle- sheathed 25 g for eus- guided , endoscopic ultrasound needle - nitinol material, 19g , eus 19g working length 1400 mm, menghini type needle , endoscopic ultrasound core biopsy needle with franseen tip design 22g , endoscopic ultrasound core biopsy needle with franseen tip design 25g , single step one action stent introducer system , over the scope clip 11mm diameter 6 mm cap compatible with adult colonoscope , over the scope clip 12mm diameter 6 mm cap compatible with adult colonoscope , reusable twin grasper forceps for deployment of over the scope clip , reusable anchor for deployment of over the scope clip , hemostatic clipping device preloaded, clip arm length , endoscopic clipping device reusable for application of multiple clips , oblique distal attachment for emr procedure , reusable endo-loop device, 230 cm length, compatible with 30 mm and 20 mm loops , preloaded over the scope clip mounted on a cap of 21mm diameter , hands free endoscope docking system , long clip for mucosal defect closure suitable for hemostatis , single use disposable electrosurgical insulated tip knife for lower gi submucosal dissection , dual knife with injector for ugi scope , dual knife with injector for lgi scope , j knife with maximum insertion diameter 2.7 mm , triangular tip knife for ugi and lgi triangle tip knife , xylocaine topical spray 10 percent , cyanoacrylate glue -1 ml for varical injection , scope channel cleaning brush , scope bite guard with strap - single use , working channel cap for olympus endoscopes , apc probe for erbe-apc system all types -230 cm , patient plate with connecting cable for erbe- electrocautery system , snaremaster for sampling- oval and crescent snare , padlock clip defect closure system, length 177 cm, supporting endoscope distal tip , padlock clip pro-select defect closure system, length 177 cm, supporting endoscope distal tip , cautery enabled one step diathermic ring and cut wire on distal tip , triple lumen ballon, multiple sizing 8.5-20mm, wire guided, distal tip , hydrophilic coating and tip, nitinol guidewire 0.035 , nitinol guidewire 0.025, 450 cm, hydrophilic coated, platinum tip, blue and white strip design , hydrophilic coating and tungsten filled tip , nitinol guidewire 0.025 450cm 5cm tungsten filled tip withhydrophylic coating twin color design , terumo guide wire straight 0.025 x 260cm- straight-angled tip , ercp canula tip 4.4 fr, working length 210 cm, recommended for 0.025 guidewire and a radiopopaque tip with coded distal marks. , triple lumen pre-curved sphincterotome with separate lumens for guidewire , biliary stone extraction baskets - all sizes , pancreatic stone extraction basket - mini-basket , wire-guided biliary stone removal basket , ercp stoneextraction basket-wire-guided, short exchange type, opening width 20 mm, length 190 cm or more , stone extraction basket 4 wire, 25 mm with detachable handle, compatible with lithotripter. , platinum based embolization coil with spaced synthetic fibers for vascular intervention and mri safe , otsc system set cap for ugi endoscope for stent fixation for endoscope od 8.5mm to 10.00mm cap depth 7mm stent fixation. , otsc system set cap for ugi endoscope diameter 8.5mm to 10.00mm cap depth 3mm pointer tip clip , otsc system set cap for endoscope diameter 10.5 mm to 12.00 mm cap depth 6 mm pointer tip clip , otsc system set cap for endoscope diameter 8.5 mm to 11.00 mm cap depth 6 mm non-pointer tip clip , coag dissector - monopolar electrosurgical instrument for blunt tissue dissection and coagulation having rotatable, flexible instrument shaft , conical design and transparent scoops forceps having a large capacity to remove necrotic ssue, blood clots, food boluses and foreign bodies. , self expandable covered esophageal st
Tender For corrigendum : rate contract of purchase of radiotherapy goods (thermoplastc masks) for two years - thermoplastic mask 2 clamp pelvis (high precision and comfortable immobilization mask), 2, per pc, 200, as above for linac 1demonstration is must, thermoplastic mask 4 clamp pelvis (high precision and comfortable immobilization mask), 6, per pc, 10, 1) excellent quality thermoplastic material,non sticky material,ct compatible 2) uniform thickness and uniform contraction during and after cooling, 2 clamp pelvis mask thickness 3.2 mm 3) nnon perforated edge offering comfortaround neck and nose usable on conventional simulator,ct/mri and other planning system 4) rigit and hould hold is shape over treatment period 5) reproducible with pri size postion 6) reusable for 23 times 7) easy to mould, comfortable to patient 8) can be shaped very closely to patients anatomy 9) shuld not obstruct path of beam 10) surface dose should not be altered 11) moment of patient contraind 12) compitible for all in one (aio) carbon fiber couch of pocl company in varian vitalbeam machine note: (1) demostration is must (2) each acceries complied with la in aio bese plate., thermoplastic mask 4 push pin clamp extrimities (high precision and comfortable immobilization mask), 10, per pc, 10, as above for cyberknife1) thickness for brain 1.6mm with micro hole2) design with 2 layers of thermoplastic material to create extra stability3) prepunched cutouts for nose only/nose and mouth/ nose, eyes and mouth, thermoplastic hybrid mask 5 clamp head and neck for cyberknife (high precision and comfortable immobilization mask) (gcri, 14, per pc, 10, as above for truebeam, tomotherapy, synergy demonstration is must, thermoplastic pediatric mask 2 point pushpin for knee and elbow extrimities (high precision and comfortable immobilization mask), 18, per pc, 10, 1) excellent quality thermoplastic material,non sticky material,ct compatible 2) uniform thickness and uniform contraction during and after cooling, 2 clamp pelvis mask thickness 3.2 mm 3) nnon perforated edge offering comfortaround neck and nose usable on conventional simulator,ct/mri and other planning system 4) rigit and hould hold is shape over treatment period 5) reproducible with pri size postion 6) reusable for 23 times 7) easy to mould, comfortable to patient 8) can be shaped very closely to patients anatomy 9) shuld not obstruct path of beam 10) surface dose should not be altered 11) moment of patient contraind 12) compitible for all in one (aio) carbon fiber couch of pocl company in varian vitalbeam machine note: (1) demostration is must (2) each acceries complied with la in aio bese plate.
Tender For supply of "9.4 tesla horizontal bore mri system with petscanner (insert/stand-alone) for small animals", "9.4 tesla horizontal bore mri system with petscanner (insert/stand-alone) for small animals with turnkey project"
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou
Tender For corrigendum : supply and installation of measuring instrument ai (artificial intelligence) ohe stagger and height measurement system as per the rdso number ti/spc/ohe/mri/0142 or latest.
Tender For supply of mri scan for smart tower wagon with advanced multi parameter sensing devices withrecording and generating reports for detailed ohe parameters like height, stagger, implantation,turnouts, cross overs, identifying type of mast, availability of structure bonds , hot spot on contact wirewith spark data analysis measurement system , online video recording camera suitable for mounting onroof of tower wagon/locomotive, features to generate reports containing (stagger, height,implantation, turnouts, cross overs, identifying type of mast etc , as per rdso specificationno.ti/spc/ohe/mri/0143, make : crystal, intra or similar
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposable syringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For corrigendum : project for supply, installation, operation and maintenance of 01 no. 3.0 tesla mri machine system along with providing investigation related services on revenue sharing basis on ppp mode for member secretary, rmrs, pbm, bikaner