Get complete information related to latest Upvc Pipeline Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Upvc Pipeline Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Upvc Pipeline Laying Tenders.
Tender For bid to ras supply of c73340100470 supply of cassette ac four way of 2tr capacity, minimum 5 star rating inverter type refer annexure iii , c73340000754 supply of split ac of 2tr capacity, minimum 5 star rating inverter type rotary or scroll compressor refer annexure iii , c73340001239 supply of window ac of 1.5tr capacity, minimum 5 star rating inverter type rotary or scroll compressor refer annexure iii , 100000000000 supply of refrigerant grade copper piping between indoor and outdoor units of suitable size refer annexure iii , 100000000001 supply of 4 core 2point5 sqmm flexible copper power cable with all fittings refer annexure iii , 100000000002 supply of cpvc sdr11 pipes of 25 mm dia with 9mm nitrial insulation refer annexure iii , 100000000003 supply of cpvc sdr11 pipes of 32 mm dia with 9mm nitrial insulation refer annexure iii , 100000000004 supply of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes refer annexure iii , 100000000005 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure iii , 100000000006 installation,testing and commissioning of cassette ac four way of 2tr capacity, minimum 5 star refer annexure iv , 100000000007 installation,testing and commissioning of split ac of 2tr capacity, minimum 5 star rating inverter type rotary refer annexure iv , 100000000008 installation,testing and commissioning of window ac of 1point5tr refer annexure iv , 100000000009 erection, testing and commissioning of refrigerant grade copper piping between indoor and outdoor units of suitable size refer annexure iv , 100000000010 laying of 4 core 2point5 sqmm flexible copper power cable with all fittings refer annexure iv , 100000000011 laying of cpvc sdr11 pipes of 25 mm dia with 9mm nitrial insulation refer annexure iv , 100000000012 laying of cpvc sdr11 pipes of 32 mm dia with 9mm nitrial insulation, for condensate water drain refer annexure iv , 100000000013 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm refer annexure iv , 100000000014 installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1oint6 mm thickness refer annexure iv , 100000000015 dismantling and shifting of existing split,cassette and window ac total 21nos refer annexure iv
Tender For supply of ac system of display hall c c -air diffusersorgrill with powder coated aluminium refer annexure iii , 100000000013 supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure iii , 100000000014 supply of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iii , 100000000015 supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure iii , 100000000016 supply of control instruments and sensors required for combined fire and smoke damper including actuators refer annexure iii , 100000000017 supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper made of aluminium refer annexure iii , 100000000018 supply of floor mounted cubicle non drawout electrical control panel for operating 3 nos ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure iii , 100000000019 supply of following size lt power cable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc outer sheathed refer annexure iii , 100000000020 supply of xlpe insulated pvc sheathed armoured copper conductor 2xfy, 1. 1 kv grade lt cable of size 4. 0 core - 2. 5 sqmm refer annexure iii , 100000000021 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1. 6 mm thickness refer annexure iii , 100000000022 installation testing and commissioning of high static pressure ductable ac unit capacity not less than 16. 5 tr having one indoor and refer annexure iv , 100000000023 erection testing and commissioning of high wall mount type hot and cold split ac units of cooling capacity not less than 2. 0 tr minimum 3 star rating inverter refer annexure iv , 100000000024 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac refer annexure iv , 100000000025 erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split ac refer annexure iv , 100000000026 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure iv , 100000000027 laying of cpvc sdr11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000028 laying of cpvc sdr11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000029 fabrication installation testing and commissioning of site fabricated gi sheet metal ducts of 24 guage birmingham gauge refer annexure iv , 100000000030 fabrication, installation, testing and commissioning of site fabricated gi sheet metal ducts of 22 guage birmingham gauge refer annexure iv , 100000000031 fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber class o refer annexure iv , 100000000032 fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure iv , 100000000033 erection testing and commissioning of volume control dampers for ducts made of gi sheet of thickness not less than 18 g including fittings refer annexure iv , 100000000034 fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer //bid details2 / 31annexure iv , 100000000035 fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure iv , 100000000036 erection testing and commissioning of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iv , 100000000037 fxing testing and commissioning of fire damp
Tender For nain - laying of parallel di pipe line in place of old ac/pvc damaged pipeline and repair of 2 no. s/s tank,boundary wall,filter media,construction of new sluice wall hodi and construction of path.
Tender For providing/laying 630mm outer dia hdpe pipe by hdd method from beri wala bagh golchakkar to wdts near subhash nagar red light in hari nagar constituency ac-28 under ee(c)-23
Tender For providing/laying 630mm outer dia hdpe pipe by hdd method from swarg ashram to beri wala bagh golchakkar to back side of deendayal upadhaya hospital in hari nagar constituency ac-28 under ee(c)-23.
Tender For bid to ras supply of supply of 1. 5 tr invertor ductable ac , itc of 1. 5 tr ductable ac , supply fixing copper piping for 1. 5 tr , supply fixing ms stand , sf upvc drain pipe 25 mm dia , sf upvc drain pipe 40 mm dia , supply laying of 3x1. 5 sqmm cable , supply laying of 3x2. 5 sqmm cable , sf dp sheet steel enclosure with dp mcb , sf 5 amps to 32 amps 240 volts spmcb , gi ducting of thickness 0. 63 mm sheet , gi ducting of thickness 0. 80 mm sheet , providing fixing aluminium grill , providing fixing canvass connection
Tender For providing/laying 630mm outer dia hdpe pipe by hdd method from cambridge school to labour chowk subhash nagar in constituency ac-28 under ee(c)-23
Tender For corrigendum : supply of ems shifting and installation for dgm office at te kankaria ahmedabad d d -point wiring group c , wiring with 2c 1. 5sq mm cu wire in pvc conduit with earthing , wiring with 2c 6sq mm cu wire in pvc conduit with earthing , s drawing 3c 1. 5 sq mm cu wire in extg conduit , s drawing 5c 1. 5 sq mm cu wire in extg conduit , s drawing 5c 2. 5 sq mm cu wire in extg conduit , s fixing piano switch 5 or 6 amp , s fixingpiano switch 15 or 16 amp , s fixing 3 pin 5 or 6 amp socket outlet , s fixing 6 pin 15 or 16 amp socket outlet , s fixing metal box with lamnated sheet cover 6 module , s fixing 5 or 6 amp modular switch , s fixing 3 pin 5 or 6 amp socket outlet , s fixing 2 stepped electronic regulator , sf modular blanking plate , s fixing single pole 5 to 32 amp mcb , s fixing single pole and neutral 5 to 32 amp mcb , s fixing 20w led in extg fitting , s fixing recessed luminire with led etc as per site reqd , sitc celing fan 1200 mm bee 3star , itc extg tl and cfl fittings , itc extg ceiling fans , sf of downrod 15mm dia gi pipe of 20cm length , endtermi for 4 c 35 sq mm al cable , endtermi for 4 c 10 sq mm al cable , laying on wall upto3. 5c 35 sq mm cable , pf 6 swg gi earth wire , s fixing 8 way double door mcb db 240v , dismentaling extg ei fittings fans wiring etc , dismentaling window or split ac units , itc of 1. 5 or 2 tr split ac units , s f powder coated iron stannd of ac outdoor unit , sf add 0. 25 inch copper pipe with cable for sac , sf add 0. 625 inch copper pipe with cable for sac , wrapping polythene foam tube on 0. 25 inch copper pipe , wrapping polythene foam tube on 0. 625 inch copper pipe , sf 3 c 2. 5 sq mm cu cond flexible cable , sf 20 mm pvc isi drain pipe
Tender For providing/laying 300mm dia dwc pipe from sanatan dharam mandir bd block to choti sabzi mandi in ward 100 in hari nagar constituency ac-28 under ee(c)-23
Tender For providing/laying 710mm outer dia hdpe pipe by hdd method from chowkhandi djb store to rts near park hospital in ward no. 97 of rajouri garden constituency ac-27 under ee(c )-23