Get complete information related to latest Urine Strips Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Urine Strips Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Urine Strips Tenders.
Tender For corrigendum : supply of sch viii (supply of needle & syringes) - sch viii (supply of needle & syringes), disposable needle sterile length 1/2" guage 25, suture needle, half circle triangular nos. 2 to 20 (cutting), insulated needle for use with peripheral nerve stimulator 22g x 2" x 50 mm., insulated needle for use with peripheral nerve stimulator 22g x 35 mm., insulated needle for use with peripheral nerve stimulator 24g x 1"x 25 mm., echogent needles for usg guided peripheral nerve blocks 20g / 21g x 100 mm., echogent needles for usg guided peripheral nerve blocks 22g x 50 mm., epidural needles 16 & 18 guage 7.5cm to 11cm (disposable), epidural needles (long length) 18g (more than 100 mm. length), sterile disposable lancet size 28-32 (plastic lancet needle type), sterile disposable hypodermic plastic syringe 20cc, cn. with leur lock, hypodermic syringes,disposable sterile, sterile pack,with/without leur lock, hub 1ml syringe with marking at 0.1 ml, asepto syringe 100 ml of heavy plastic barrel and rubber bulb with marking., bag arm rubber with cover for b.p. apparatus, adult size velcro.rubber bag size 13 x 23 cms., keratome, size 2.8 mm, type-regular(ophthalmic), angle-45 degrees, bevel type- bevel up (pointed)blade-stainless steel/carbon steel,handle- polycarbonate, use- disposable single use, mvr, gauge 23g type-regular(ophthalmic), blade-stainless steel handle- polycarbonate, use- single disposable use, triple lumen catheter 7.5fr with 14g distal lumen, length-15cm. kit contain 1 teflon-coated j nitinol guidewire particularly kink-resistant with guide-advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18g, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short iv cannula, double lumen subclavian/ jugular catheter kit (adult) ptfe (teflon) cannula curved od 2.7/d 11.5fr-12fr/chx5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s clamping extension, clamp luer lock "y" connector with protective caps size 12.5, 15 with guide wire introducer needle, dialator , 3fr double lumen cvc catheter with 60mm double-lumen polyurethane central venous catheter inserted by seldinger technique, radio opaque material for catheter, the user should be able to choose from 2 type of introducer, i.e.needle 23g or i.v. cannula 22g, latex free, the central venous catheter set should contain: 1 double-lumen polyurethane 3fr catheter, 1 short i.v. cannula 22g, 1 introducer needle 23g, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1.5 ml syringe, peripherally placed radiopaque central single lumen catheter. guage 14/16 (100%) (needles size/catheter size) length - 55cm - 70cm, peripherally placed radiopaque central single lumen catheter. guage 18/20 (100%) (needles size/catheter size) length 30cm - 45cm, fully radiopaque pur catheter 16g for femoral artery centimeter marking from 5-15cm, winged hub for skin fixation, supple distal tip. kit should contain 1 pur catheter with xro lines,1 puncture needle, 1 j guidewire with wishbone-type guidewire advancer, 1 dilator, radial/femoral arterial pe catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.catherter size g- 18, length 10cm, radial/femoral arterial pe catheter 20g, 8cm puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). the needle is also fitted with a silicone bloodless system valve to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire, peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leur connector at proximal en
Tender For providing of customized amc/cmc for pre-owned products - customized amccmc for pre-owned products - supply of equipments for polyclinic as per required demand; supply of equipments for polyclinic as per required demand; comprehensive maintenance contract (cmc); not applicable; no digital thermometer, stethoscope adult, digital weighing machine, led torch, measuring tape, non stretchable measuring tape, aneroid bp monitor, infantometer, pulse oximeter, fetal doppler, wooden tongue depressor, autoclave drm set, kidney trays, opthalmoscope direct, slit lamp, digital led vision chart, digital led vision chart, jobson home probe, led head light, tuning fork, ear speculum, view box, digital bp machine with stand, stethoscope pediatric, pediatric bp cuff, surgical blade with handle, needle holder, artery forceps, mucous extractor suttiontube, trial frame adult and children, trial lens set, punctum dilator, near vision chart with different langue, anural speculum, square trays, shoulder wheel, wall ladder finger exerciser
Tender For supply of consumables of cardiac catheterization lab for gbph, sri vijaya puram - puncture needles (adults), puncture needle for vascular access in adults 18 g 6- 7.5 cm long should be compatible with 0.038 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, puncture needle dedicated for radial artery access in adults 20- 22 g 3- 5 cm long should be compatible with 0.021 - 0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for vascular access in adults 20- 22 g 6- 7.5 cm long should be compatible with 0.018 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for radial artery access in adults 20-22 g 3-5 cm long should be compatible with 0.021-0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, introducer sheaths (adults), introducer sheath for adults and pediatrics (sizes 4 -9fr.) - standard length sizes 4- 9 fr 10- 11 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath with puncture needle for adults (size 5- 9 fr) - standard length sizes 5- 9 fr 10-11 cm long pack must include 18 g, 6- 7.5 cm long puncture needle 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, long introducer sheath (size 6- 7fr) 20-50 cm long sizes 6- 8fr sheath should be between 20-50 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath for radial access introducer sheath dedicated for transradial access sizes 4- 7 fr between 7- 16 cm long 0.021 - 0.025 inch guide wire compatible pack must include 20-22 g, 3.5 cm long puncture needle with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath m coat hydrophilic coating kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer slender sheath for radial access transradial slender sheath systems 5f 10 cm capable of introducing 6f catheter with hydrophilic coating on sheath ,tapering dilator hydrophilic straight polymer 0.025 wires and 20g plastic cannula for puncture . should be fda/ce/dcgi approved, introducer slender sheath for radial access transradial slender sheath systems 6f 10 cm capable of introducing 7f catheter with hydrophilic coating on sheath, tapering dilator hydrophilic straight polymer or stainless steel 0.021 or 0.025 wires and 22 g / 20g plastic cannula for puncture should be fda/ce/dcgi approved, guidewires (adults), ptfe coated diagnostic guide wire - regular length, regular stiffness should be available in 0.025, 0.032, 0.035 and 0.038 inches size should be between 145- 180 cm long should be available as straight & j shape tip should be available in variable lengths of flexible/floppy end should be available in variable j tip sizes should be available in fixed as well as movable core, ptfe coated diagnostic guide wire - exchange length, regular stif