Tender For supply of miniature circuitbreaker traction duty, 6 amps / 5 amps, single pole, 240 v ac, as per is/iec:60898-1:2002 type c with extended connecting terminals but without fixation bracket. extended connection terminal arrangement will be as per rdso drg. no. skel 3700 alt-1 with clause 4.4.2 of specification spec/e-12/1/04 amendment - 1, june - 1993 . specn/drg no. is/iec: 60898-1: 2002 ( except for terminal arrangement, only which should be as perrdso drg. no. skel 3700 alt-1 ) [ warranty period: 30 months after the date of delivery ]
Tender For supply of circuitbreaker 3 pole for tm blower and oil cooling unit transformer/converter along with auxiliary contact (2 no type)as per clw spec. no. clw/es/3/0096 (alt.-l) (63 amp) [ warranty period: 30 months after the date of delivery ]
Tender For supply of ac circuitbreaker 6a, 3 pole (type-18) with aux. contact "2 no" to spec. no. clw/es/3/0096/l (one set comprise of 01 nos. of ac circuitbreakers along with "2 no" type aux. contact qty. 1no. ref no. ng125h3p10ac18723 auxiliary contact 19071. [ warranty period: 30 months after the date of delivery ]
Tender For miniature circuitbreaker (mcb) 5 amp type 'c' single pole 240/415v ac ,10ka breaking capacity conforming to is/iec-60898-1:2002 incorporating mounting of body as per rdso drg no-skel-3700, alt-1 with extended terminal suitable for bg ac emu/memu. make-legrand/havells/indoasian. firm shall submit valid dealership certificate and test certificate from oem along with supply. [ warranty period: 30 months after the date of delivery ]
Tender For supply of earth leakage circuitbreaker (elcb), current rating 25 amps, double pole, rated sensitivity 30 ma, voltage rating 230-240 volt ac as per rcf specification no. edts-130 rev. b, corr. 06 or latest. ]
Tender For supply, erection ,testing and commissioning of 25 kv ,2000 a double pole circuitbreaker as specification ti-spc-psi-lvcbin-0121withacslipno1. [ warranty period: 30 months after the date of delivery ]
Tender For supply of rcbo (residual current circuitbreaker with over load) 4 pole 16 amp, 415 v ac , sensitivity 30ma , breaking capacity 10 ka, din rail mounted similar to cat. no. 603395 of legrand. make-approved make as l & t/ mds/ legrand/ siemens. [ warranty period: 12 months after the date of delivery ]
Tender For corrigendum : supply of 1. mpcb for ventilation fan unit 1 & 2, thermal release range(rated current) : 2 . 5 - 4 a, class-10,2. residual circuitbreaker with overload (rcbo) 4 pole, 16 amps, 415 v ac,