Get complete information related to latest Vacuum Pressure Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vacuum Pressure Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vacuum Pressure Pump Tenders.
Tender For corrigendum : supply of call base ems repair at bsnl oa himatnagar - attending fault at te below 25 km , attending fault at te 25 to 50 km , attending fault at te more than 50 km , sf 12v 88ah battery , sf 12v 130ah battery , sf 10amp 12v smps battery charger , repair smps battery charger , service of dg set 40 to 62.5kva , service of dg set 100 to 125kva , service of dg set 320 kva , 320 kvadg set starter repair , calibration of fuel pump and nozzle , service radiator for ea set upto 125 kva , service radiator for ea set upto 160 to 320 kva , rewinding 3 to 5 hp mono water pump , dol starter for 5 hp motor , repalce sreet light with 25 watts led lamp in holder , repalce sreet light with 25 watts led lamp on pole , repalce pvc box , sf 4 ft 20 w white led tl , sf 3 c 2.5 sq mm cu cond cable , sf 3 c 1.5 sq mm cu cond cable , laying xlpe cable upto 35 sq mm , end termination for 4c 10 sq mm cable , dismental ac unit incl all , shifting of 1.5 tr sac unit incl all , itc of 1.5 or 2 tr split ac units , charging r 32 or r410 gas for sac , charging r 407 gas for sac , sf add copper pipe with cable for sac , sf25 mm pvc isi drain pipe , disemntaling all ems , servicing mv and lt panels incl all , repalce 400 a mccb incl shift and itc
Tender For corrigendum : supply of call base repair of ems at bsnl oa palanpur - attending fault at te below 25 km , attending fault at te 25 to 50 km , attending fault at te more than 50 km , sf 12v 88ah battery , sf 12v 130ah battery , sf 10amp 12v smps battery charger , repair smps battery charger , service of dg set 40 to 62.5kva , service of dg set 100 to 125kva , service of dg set 320 kva , 320 kvadg set starter repair , calibration of fuel pump and nozzle , service radiator for ea set upto 125 kva , service radiator for ea set upto 160 to 320 kva , rewinding 3 to 5 hp mono water pump , dol starter for 5 hp motor , repalce sreet light with 25 watts led lamp in holder , repalce sreet light with 25 watts led lamp on pole , repalce pvc box , sf 4 ft 20 w white led tl , sf 3 c 2.5 sq mm cu cond cable , sf 3 c 1.5 sq mm cu cond cable , laying xlpe cable upto 35 sq mm , end termination for 4c 10 sq mm cable , dismental ac unit incl all , shifting of 1.5 tr sac unit incl all , itc of 1.5 or 2 tr split ac units , charging r 32 or r410 gas for sac , charging r 407 gas for sac , sf add copper pipe with cable for sac , sf25 mm pvc isi drain pipe , disemntaling all ems , servicing mv and lt panels incl all , repalce 400 a mccb incl shift and itc
Tender For repair and overhauling service - repair and overhauling services dsl l-50 to l-55 , e-41 to e-44 and h-69 for icgs c-411; dsl l-50 to l-55 , e-41 to e-44 and h-69 for icgs c411; no; buyer premises-icgs c-411 l-50: ship s boat davit not working due to defective rotary switch (25 amp, qty-02 nos.) and 10 pin male & female connector (20 amp) of remote assembly is broken/defective. defect to be rectified and proved for satisfactory operation. in-way job includes renewal and fitment of rotary switch and connector as per sample l-51: 01 no. ecdis ups (make-apc, cap-1500 va, 865 w) not working due to defective charging circuit and defective converter. defect to be rectified and proved for satisfactory operation. l-52: ship is fitted with 08 nos. flood lights (mercury/halogen type) onboard. all flood lights to be repaired/replace with flood lights as per policy in vogue. in way job includes removal and fitment of lights, clamps and wiring as per standards and proved for satisfactory operation. l-53: 01 no. hand set ptt of mf/hf communication unit (make: samyung, model: srg-2250) and 01 no mic of hf marine (make: icom, model: ic m802) is malfunctioning due to defective mic/cable and multi pin connector. defect to be rectified and proved for satisfactory operation. l-54: 02 in nos. splash proof microphone of main broadcast is malfunctioning due to defective mic and multi pin connector. defect to be rectified and proved for satisfactory operation. l-55: 02 in nos. of exhaust/supply fan in waterjet compartment not working due to defective bearing and showing low insulation. defect to be rectified and proved for satisfactory operation. in-way job includes repairing/renewal of motor trunking and welding of supporting clamps as per sample (mat: ss clamps and gi sheet) e-41: leakage observed in 02 nos. fuel ball valve in engine room. ball valve to be overhauled and pressure test to be done up to 1.5 times of working pressure. (dia: 50 nb, working pressure: 1.5 kg/cm2) e-42: performance of ac plant observed to be low view scaling found in ac condenser.ac condenser to be chemically cleaned and gasket (both ends) along with nut & bolt to be renewed as per sample. (gasket mat: rubber, nut & bolts mat: ss 316) e-43: 02 nos shaft seal cooling hose of waterjet along with adapter deteriorated due to aging/long usage. hose/adapter to be repaired/renewed as per sample. (mat: rubberized pressure hose, length:1.5 mtrs. e-44: domestic sea water pump is not developing sufficient discharge pressure. sea water pump to be overhauled and proved for satisfactory operations. inway job includes removal and fitment of pump to done. h-69: wooden locker at dining hall deteriorated and cracked. door of the locker perished. locker to be repaired/renewed. mat: wood..