Web Analytics Made Easy - StatCounter

Valley Gutter Tenders

Get complete information related to latest Valley Gutter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Valley Gutter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Valley Gutter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39616980 Due date: 21 Mar, 202521 Mar, 2025 24.98 Lacs
Tender For repair to valley gutter, hangar doors, flooring works, plinth protection and allied work in tech area at af station chakeri kanpur

CTN :39616449 Due date: 20 Mar, 202520 Mar, 2025 1.74 Crore
Tender For repair/replacement of roof, valley gutter, down take pipe, etc in sm-ii shop (bldg no. 130) and attached compressor house, bhno. 2 (butler hanger no. 02), bldg. no. 10 (main store), gs-iii (bldg no. 182) inside ofc.

CTN :39616310 Due date: 27 Mar, 202527 Mar, 2025 25.00 Lacs
Tender For annual percentage rate contract on mes ssr 2020 for civil maintenance works, including masonry, joinery , false ceiling, roof repair (including valley gutter, rain water pipes etc.) concrete work, water supply, sanit

CTN :39576459 Due date: 20 Mar, 202520 Mar, 2025 37.76 Lacs
Tender For periodical cleaning of valley gutters inside factory at hvf factory.

State Government

CTN :39577578 Due date: 17 Mar, 202517 Mar, 2025 1.00 Crore
Tender For tender for supply of surgical and disposable item - 3 way stop cock , non pyrogenic and single use, should be leak proof, with smooth movements, 3 way stop cock with extension tube (vein-o extension line) size 10cm (non pyrogenic & single use), 3 way stop cock with extension tube (vein-o extension line) size 150cm (non pyrogenic & single use), abdominal belt, abdominal drain kit (with collection bag 2000 ml size 24, abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 16), abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 20), abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) size 28, abdominal drain kit,sterile,having drainage cather and collection bag(2000) ml size 32, absorbable gelatin sponge 80 x 50x 10mm, absorbable oxidized regenerated cellulose netsize 2 x 3 topical absorbable haemostatic bactericidal property, absorbent cotton wool 300 gm, absorbent cotton wool 500 gm, adult ventilator circuit single water trap, adult ventilator circuit with universal single limb, advance bipolar hand activated probe with 5mm shaft diameter and 35 cm shaft length with 5 mm wide, anti microbial gloves 6.5 inches, anti microbial gloves 7 inches, anti microbial gloves 7.5 inches, apple hunt trocar :- should be single use sterile trocars, have side port , two cannula & one trocar ,5 mm & 10 mm trocar with pyramidal tip, ergonomic design , fascia anchoring thread should be usfda / ce approved, aprin plastic disposable, arterial pressure monitor lines (100 cm long), arterial pressure monitor lines (150 cm long), asepto syringe with transparent bulb sterile, 60 ml, baby kit (cloth set for new bourn babies in summer use), baby kit (cloth set for new bourn babies in winter use), baby diapers pkt. of 5 pcs., band aid (water proof) long, bed paan plastic, bed protective plastic sheet disposables size 120x210cm, blood administration set blood transfusion set, breast pump, barbia three way foleys 22 fr, cannula fixer, care handloom guaze pad ( sanitary pad) pkt. of 10 pcs, carter thomason port closure :- should be carter thomson type port closure system, have pilot guide and suture passer separately, able to use for trocar defects of 5mm - 15mm, suture guide holes should be 180 degree access across each other s, single use , catheter,size 10(foleys ballon catheter sterile,2 way for urinary drainage,single use,)silicon coated natural latex material, catheter,size 16(foleys ballon catheter sterile,2 way for urinary drainage,single use,)silicon coated natural latex material, catheter,size 18(foleys ballon catheter sterile,2 way for urinary drainage,single use,)silicon coated natural latex material, catheter,size 8(foleys ballon catheter sterile,2 way for urinary drainage,single use,)silicon coated natural latex material, ceasarian drape sheet, central line triple lumen with y needle and nitinol guide wire 7fr to 8.5 fr with 15cm to 20cm catheter with tecoflex/polyurathane material, central neck line ? double lumen (antimicrobial coated/ chlorhexidine , silver sulfadiazine coated) central lumen catheter, double lumen) 7 fr, close suction system adult fr-14, close wound drainage device under negative pressure (closed wound suction unit) 10 no, close wound drainage device under negative pressure (closed wound suction unit) 8 no, close wound drainage device under negative pressure (closed wound suction unit) no. 12, close wound drainage device under negative pressure (closed wound suction unit) no. 14, close wound drainage device under negative pressure (closed wound suction unit) size of bellow 800 ml, catheter size 16, close wound drainage device under negative pressure (closed wound suction unit) size of bellow 800 ml, catheter size 18, combined spinal & epidural set latex free disposable pencil point spinal needle 27g , 127.5 mm with grooved transparent hub with centering protective plastic sleeve, touhy needle with black

Central Government/Public Sector

CTN :39214392 Due date: 11 Mar, 202511 Mar, 2025 11.56 Lacs
Tender For corrigendum : provn of pcc hard standing, area drainage and connected item near adm building at dabathwa and incinerator and connected item at dcn sub gp under ge (south) meerut cantt

CTN :39544951 Due date: 23 Mar, 202523 Mar, 2025 25.00 Lacs
Tender For annual percentage rate contract on mes ssr 2020 for civil maintenance works including masonry, joinery , roof repair ( including valley gutters, rain water pipes) concrete work, water supply, sanitary, fabrication and connected works in store bldgs,

Corporations And Associations And Others

CTN :39545009 Due date: 10 Mar, 202510 Mar, 2025 3.88 Lacs
Tender For imp dev of drainage system by pdg b w rcc item etc in shiv vihar in ward no 38 prem nagar ii in m-ii rz

Corporations And Associations And Others

CTN :39545010 Due date: 10 Mar, 202510 Mar, 2025 3.90 Lacs
Tender For imp dev of drainage system by pdg b w rcc item etc in naryan vihar in ward no38 prem nagar-ii in m-ii rz

CTN :39542182 Due date: 24 Mar, 202524 Mar, 2025 5
Tender For tender for supply of soil investigation - consultancy services for digital topographical land surveying 9.97 acres by using electronic total station , showing all existing details like bldgs , fencing boundary wall , road and existing drain with invert level , existing main sewage line , spot level at 5.00m into 5.00m , and contour interval at 0.20m. marking of bm and tbm as directed by ge , marking of proposed area drainage , sewage disposal , road path culvert , external water suppluy , external electric supply , compound wall fencing gate and rain water harvesting and submission of drawings in autocad format 10 sets of colored drawings in soft copy in cd and 10 nos of data in hard copy in good quality paper approved by garrison engineer. , soil investigation of blgs to be carried out by a nabl accredited soil investigation agency govt engg college as per nbc is 1802 2131 2132 1888 2720 1904 6403 8009 1498 4968 and sp36. making bore hole of 150 dia upto 6 mtr depth below ground level collection of disturbed and undisturbed soil sample of an internal range of 1 mtr to 2 mtr performing spt at an interval of 0.75 mtr depth or at every change of soil starta which ever encounter first incl soil classification tests and bore hole of log data and evalution of safe bearing capacity and recommendations of type of foundations for suitability of earth obtain from foundation trenches including salinity test and chemical analysis of soil including following details. please see specification of document. , ditto- same as item no 2 above but depth upto 10 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation. , ditto- same as item no 2 above but depth upto 15 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation. , ditto- same as item no 2 above but depth upto 15 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation.
 Loading, Please wait...

Connect us via What's Up