Get complete information related to latest Valve Fitting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Valve Fitting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Valve Fitting Tenders.
Tender For supply, installation & commissioning of spare parts of air dryer model ur - 700(m) , serial no-37-8-2017 work included with supply and fitment of evaporator - 01 no, freon gas-as per requirement , gas filter- 01 no , expansion valve - 01 no and service charges including to & fro and boarding . make - ultrafilter or similar .
Tender For brief scope of work covers 1) routine maintenance works of valve house, penstocks and auxiliaries, 2) replacement of penstock expansion joint worn out hemp packing with greasing, 3) tightening of water leakage expansion joints (heavy water leakage arresting works) with greasing and 4) greasing of penstock saddle legs for penstocks as specified in detailed technical specification and scope of work furnished in section-iii- of bid document attached in the e portal.
Tender For supply of open type recip compressor bitzer model6g2y-k , ac plant 47 tr , valve plate assembly part no. 08498 , set shaft seal part no08012 , set piston-conn.rod w.3 rings part no. 08491 , set piston dia 80 (optimized) part no. 80106 , set connecting rod part no. 08435 , set shut-off valve nw38 part no. 08398 , set shut-off valve nw50 part no. 08087 , set sight glass part no. 08130 , set cylinder cover standard part no. 08830 , set front bearing part no. 08179 , set rear bearing part no. 08465 , set oil pump part no. 08795 , set oil filter not shown part no. 08457 , filter suction side part no. 05983 , pressure regulator oil , cpl. part no. 04965 , shut-off valve 7/16 unfx1by4 part no. 07559 , set of gaskets for condenser 47tr ac plant for ekm submarine , bolt for cathodic protector , set of gaskets for evaporator47tr ac plant for ekm submarine , flexible coupling model qdc-276/80 ns , thermo expansion valve sporlan mve-26 vc charge7/8 , filter drier sporlan c14411g 1-3by8 ods , liquid line strainer 1-3by8 ods , valve globe type 2-1by8 ods , check valve in discharge line , globe valve in liquid line , locking screw 1by8 nptf part no. 05514 , hexagon head screw m10x75 part no. 06828 , hex. head screw m8x70 part no. 05439 , sealing cap 5by8 unf part no. 05547 , union nut 5by8 unf part no. 05531 , hex. head screw m16x110 part no. 05755 , hex head screw m12 x 80 part no. 05467 , ring screw m12 part no 06236 , union nut 7by16 unf part no. 05528 , seal ring 27x22xx2 part no. 05342 , threaded pin din 8906 part no. 05540 , hex. head screw m10x30 part no. 05846 , set oils.heat.140w 110-130 part no. 08430 , hex head bolt m16x2x60l nab , hex nut m16x2 nab , washer spring , jack-screw , compressor discharge pressure gauge , compressor suction pressure gauge lube oil , pressure gauge 65 dial 0 to 60 kg cm2 for water , sw pressure gauges , seawater differential pressure gauge , temperature gauge 100 dial 0 to 100 deg c , temperature gauge 100 dial -30 to 50 deg c , sw temp gauges , pilot operated solenoid valve sporlan 180s with24v dc coil , safety valve condenser , drain purge valve for condenser , charging valve , 3 way isolation valve for pressure gauges , bearing front nu216 , brush bracket assembly for 45 kw motor , fan , bearing rear nup 216 , feed thru capacitor for 45 kw motor , mccb merlin gerin 160 a , 4 pole ns160n 4p30640 coil 24v dc , integrated gate bipolar transistor mitsubishi 300a , 600v , capacitor ctr eqv 330 m f 400 v screw type , dc shunt meco 300a 75mv cl 05 i-type , dc voltmeter conzerv 0 to 500 v dm 3290 cl-1 96x96 sq mm , ac ammeter conzerv 0 to 300 a dm 3291 cl-1 96x96 sq mm , starter card elmot for 45 kw dc panel , field regulator circuit elmot for 45 kw dc panel , lamps self test card elmot , wiring diagrame plate elmot , set capacity regulator 24 v dc , compressor suction pressure switch , compressor discharge pressure switch , temperature switch danfoss rt7 -25 to 15 deg c , filter drier core , tachogenerator (hubner make) , piri terminal block (6way) , set start unloader 24 v dc , current transducer lem 200 a hal 200-s , dc contractor telemecanique 20a 4p lc1dt20bd coil 24v dc , control replay telemecanique 10a ca3kn22bd coil 24v dc , indicating lamp telemecanique 24v dc xb7ev04bpn red , indicating lamp telemecanique 24v dc xb7ev04bpn green , indicating lamp telemecanique 24v dc xb7ev04bpn amber , push button with no element telemecanique xb5aa42n green , push button with nc element telemecanique xb5aa31n red , emergency pb with nc element telemecanique xb5as542n red , starter fault reset pb with 2 no elements sb l and t 6a 250v red , lamp self test pb with 1 no element sb l and t 6a 250 green , hooter reset pb with 1 no element sb l&t 6a 250 red , on-delay timer siemens 5-100 sec coil 24v dc 3rp15 13-1ap30 , on-delay timer siemens 5-10 sec coil 24v dc 3rp15 11-1ap30 , slf fuse gilard 5 a , frc fuse gilard 2 a , terminal connectors with din rail 35 wago 2.5 sq mm 280-101 , terminal connectors with din rai
Tender For supply, installation, testing and commissioning of 2 no. chillers with cooling tower in central ac plant of main hospital at skims soura - sitc of vfd based, ahri/ eurovent certified, water-cooled, mono/ twin screw type chiller of capacity not less than 100 tr with allied items. the item shall be complete and ready to be connected with main headers in the existing central air conditioning plant of skims soura. the chiller shall be accompanied with microprocessor based control panel with all safety, switch gears needed for safe, smooth and hassle-free operation. the job includes laying of foundation as per oem recommendation which shall be not less than 6 inches above the finished floor level. the technical specifications are further detailed in annexure b., sitc electric-motor driven centrifugal pump for condenser and chiller sides having a discharge of 15 to 18 litres per second, head of 30 metres, 1450 rpm. the technical specifications are furhter detailled in annexure b., insulated chilled water piping (nitrile rubber insulation)supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg/ cum density, thermal conductivity 0.037 w/mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.note: the pipes of sizes 150mm & below shall be m.s. c class as per is: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia., 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulationthickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulation thickness), 100 mm (32mm nitrile insulationthickness), 80 mm (32mm nitrile insulation thickness), 65 mm (32mm nitrile insulationthickness), sitc of butterfly valves with di body double flanged construction with epdm coated disc with long pitch and pn 16 pressure rating as per is 13095 (1991), 250 mm , 150 mm , 125 mm , 100 mm , 80 mm , 65 mm , providing and fixing of aluminum cladding of 0.63 mm thick sheet to the insulated pipelines including bends, valves, fittings, etc. the job includes grooving, providing and fixing of screws, washers etc. as per is : 2676 - 1981, 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulation thickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulationthickness), 100 mm (32mm nitrile insulation thickness), 80 mm (32mm nitrile insulationthickness), 65 mm (32mmnitrile insulation thickness), sitc of ductile iron non-return valve of following size with allied jobs as per site requirement. the valve shall be conforming to is-5312. pressure rating : pn16, 150 mm , 125 mm , 100 mm , sitc of y-strainer (ci) flanged end, of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , 100 mm , 80 mm , sitc of balancing valve (ductile iron) of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , sitc of t-strainer (c.i.) of following size with allied jobs as per site requirement. pressure rating : pn16, 250mm , sitc of fully stainless steel pressure gauge (bourdon beryllium copper, socket ss316l, case and bazel ss304), rugged construction with epdm blowback, safety glass. 0-40 kg/cm , dual display bar/psi or selectable, sitc in position the bi-metal dial thermometer temperature guage 4 dail size bsp (m) connection, ss case and ss wetted parts completer as required, sitc of air release valve of following size. air release valves shall be provided at all higher points in piping system for venting., 25 mm dia , sitc