Get complete information related to latest Varistor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Varistor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Varistor Tenders.
Tender For corrigendum : supply of procurement of spares of prabhu make auto transformer starter panel 6 6 kv at pump section dep d d ? g? g - isolator 400a 6 6kv part no ht100a , vacuum contactor 400a 6 6kv part no ht200 , contactor tp 12a ac3 duty fitted with 110v dc coil tp1d210 for vacuum contactor part no ht200a , metal oxide varistor 510 20 for vacuum contactor part no ht200b , diode by255 for vacuum contactor part no ht200c , vacuum contactor closing coil 110v dc part no ht203 , vacuum contactor holding coil 110v dc part no ht204 , ht control fuse 6 6kv 2a part no ht400a , resin cast moulded cbct part no ht500a , dmc insulator and power fuse 6 6kv part no ht700a , el unit without transformer 0 point 5 to 2a part no ht800 , hrc fuse link 1a part no ht1201 , is pilot panel complete with base electronic per 3 part no ht3000 , oil cooled copper winding auto transformer starter part no tr1100kw , realy for winding temperature or bearing temperature part no ht4006 , timer electronics 3 sec to 3 min on delay ht2004a , microcontroller based ct operated motor protection relay with different protections , over voltage and under voltage relay overvoltage 105 percent to 120 percent and uundervoltage 75 to 95 percent minisec part no ht4004
Tender For corrigendum : purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopa
Tender For supply and execution of various signalling equipments as per boq attached inspection rites consignee - fabrication and supply of point rodding (ground connection) set with insulation complete set for electric point machine 220 mm stroke clamp type for thick web switches as per rdso drg no rds0/s/3454 alt -a ver-1 or latest. (inspection agency:- rites), supply and fixing of gi bend pipe 50 mm dia., bclass, for cable entry into point machine with all accessories. note: th is item to be operated independently for those points where point machines are functional, but gi bend pipe is not provided. for all other new installation of point machines, item 06002 of the sor includes the provision of gi bend pipe. (inspection agency:- consignee), supply of point machine ground connection insulation complete set including for p bracket insulation for point machine irs type 220 mm.(inspection agency:- rites), supply of stretcher bar insulation complete set for point machine irs type 220 mm stroke clamp type.(inspection agency: - consignee)., supply of track lead junction boxes fiber glass as per drg.no. cwm - 00597 of f.r.p material to irs.s.23 specification along with fixtures i.e., on ms angle 50x50x5mm, 0.9 meters long two numbers of g.i. pipes of 25mm dia. along with nuts and bolts and 500mm long (this includes gromite bushes, 60mm pbt terminal). (inspection agency:- consignee), supply of aluminium ladders of height 5 feet for maintainer at relay room and ips room of model no: 8226 of youngman, plantex or similar. (inspection agency: - consignee)., supply of lps 3.00 mm thick rolled copper strip of reputed branded make. (inspection agency: - consignee), supply of insulation resistance tester. make fluke 1507 or similar. (inspection agency:- consignee), supply, fabrication and fixing of the calling on board/bslb board as per rdso drg. no. sa 2373 (adv)/stop/warning board as per drg. no. sa-2380 (adv), or as applicable, on concrete foundation and painting with retro reflective paint. all work to be carried out as per railway site engineer instructions.(inspection agency:- consignee), supply, fabrication and fixing of retro reflective signal number plates as per ncr drg. no. typ/14/0014 dtd 28.11.2014 issued vide ncr letter no. s&t/ ncr/drg/typ dated 28.11.2014, on signal post with contractors own material like clamp, u bolts, nuts etc.(inspection agency:- consignee), supply of digital cable fault locator for metallic s&t cables of reputed make as per tec spn no. gr/tie-05/03, july 2006 & tec 73060:2006 like khushicomms model venus 120 orsimilar branded make. consignee shall approve the supply only after successful demonstration at site(inspection agency:- rites), supply and testing of cable route tracer and marker locator model and make 3m dynatel model locator 2273m or reputed branded make.(inspection agency:- rites), supply, installation and commissioning of central gateway. note: single centre gateway shall cater maximum up to 32 data transmitter node (modbus).(as per annexure a) (inspection agency:- rites), supply, installation, testing and commissioning of data transmitter node in location box. modbus type note: maximum range 400 meter. (as per annexure b) (inspection agency: - rites), supply, installation , testing and commissioning of data transmiter modbus cum repeater for augmenting range of ourdoor data transmiter node (modbus), where distance of location box is more than 400 meter with respect to central gateway.(as per annexure c) (inspection agency:- consignee), apparatus case led indication status display unit cum allarm system for yard.single display system shall cater to maximum 45 no of location boxes.(as per annexure d)(inspection agency:- consignee), fabrication, supply and fixing of p, c, a, g, ibs etc. marker disk painted and lettered with enamelled paint of approved colours, on signals, conforming to rdso drg. no.sa - 23456, as per standard practice and technical specifications.(inspection agency:- consig