Get complete information related to latest Vascular Stent Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vascular Stent Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vascular Stent Tenders.
Tender For supply of 1) aortic root cardioplegia cannula with stylet two channels for infusion pressure monitoring line and infusion lines to have luer type connection. 2- channel 9fr & 2) aortic root cardioplegia cannula single channel 7 fr with vent line
Tender For e-bid for rate contract cum supply and empanelment of surgical items - braided e caprolactonecoated lactomer 1, 90cm gs-25,37-40mm1/2 circle taper point, braided e caprolactone coated lactomer 2-0 90cm gs-25,3omm1/2 circletaper point, polypropylene blue monofilament, 2-0, 90 cm 1/2 circle round body double needle 26 mm, polypropylene blue monofilament usp3/0,2,90 cm,1/2 circle taper point (double armed),26 mm, polypropylene blue monofilament, 4-0, 75 cm 1/2 circle round body double needle 17 mm, hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,9cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels up to and including 5mm in diameter, with ergonomic symmetrical finger ring grip-focus 9, hand activated curved taper tip coagulating shears compatible with ultrasonic cutting and coagulation device,17cm length,16mm curved active blade with adaptive tissue technology capable of sealing blood vessels upto and including 5mm in diameter, with ergonomic symmetrical finger ring grip - focus 17, synthetic oxidised re- generated cellulose double layered with peg and trilysine size 5*10cm or size 5-7 x 7-11 cm or size 4x 8 inch, double wall resuscitator with peep valve in paediatricsit should be fully autoclavable double wall with hand strapit should be supplied with autoclavable reservoir bag it should have a singleshutter valve system made of silicone rubberit should have easy attachment of peep valve for peadiatricit should have provision to attach manometer for paediatrics ambu bagbag volume: mark iv baby (300 ml)weight: baby (190 g)it should be us-fda, ce & iso certified, ultrasorbs ap disposable drypads,dry pad for moisture management, 58.4x90cm, with breathable layer, super absorbent core, aqua shield film and air permeable back sheet, absorbency of 1800- 2300gm, usfda/ce/biscompliant, iso13485 compliant, volumetric incentive spirometer (adult) volumetric incentive spirometer (adult) 4000 ml with handle. volume measurement must be compact comfortable designed to accommodate large inspired volumes. must have good-better-best flow window & advanced, low work-of-breathing design.particulate filter screen in device housing must help to reduce risk of foreign matter passing to patients.expandable and collapsible tube must help patients find comfortable position for treatments and can be removed when storing the device. ergonomic swiveled mouthpiece allows to patients create tight seal to enable more accurate measurement. flow indicator with smiley face provides visual target for desired inhalation and bright green flow indicator make it easy for patients to see results. manufacturer must be us-fda registered & certified with en/eu iso 13485 & applicable 510k &ce certification., neonatal high flow cannula having 8 litreflow. it can also be used for hfnc + nippv/cpap. should have a soft tip., pur-xro catheter 20 cm, 28g/1fr picc line with stylet, splitting needle with securing wings with 8cm extension tubing ( flow rate 0.7ml/min)., pur-xro catheter 30 cm, 24g/2fr picc line with split cannula and 10cm extension tubing over catheter (flow rate 4.5ml/min)., silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), silicone foleys catheter with three noble metal alloy coating consisting of gold, silver & palladium (coated internally & externally surfaces), long term double lumen dialysis catheter with kit accessories should be provided ( catheter,pull apart sheath, dialator, tunneling stylet,guide wire j/s,with disppencer and injection caps, symmetrical tip retrograde and antigrade long term double lumen dialysis catheter size 15 fr x 23 cmusfda certification, absorbable
Tender For e-bid for rate contract cum supply and empanelment of surgical items - "sterile disposable perfusion set (infusion set) with airway and needle (paediatric use) burette type measured volume chamber of 100 ml drop size of approx 60 drops per ml injection port,latexfree, for intermittent medication. floating auto shut off valve (latex free) in burette. soft and kink resistant pvc tubing. roller controller for flow control tube length 150 cm 23g needle as per iso 8536-5", "sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 20g should be packed in transparent, single blister pack. as per is 10555 standard", "sterile disposable (single use) teflon / ptfe i.v. cannula with integrated 3 way stop cock. size 22g should be packed in transparent, single blister pack. as per is 10555 standard", "sterile disposable (single use) teflon/ ptfe i.v. cannula without port. size 24g suitable for paediatric & neonatal use should be packed in transparent, single blister pack. as per is 10555 standard", "plaster of paris bandages 15cm x 2.7mts / roll testing parameter should befollowed as per bp standard", urine collecting bag, disposable 2000 ml transparent sheet kink resistant flexible tubing not less than 90 cm in length should have non-return valve top drainage outlet graduated bag moulded handle for easy handling, vaccum suction set, 2.5 meter length, suction handle with suction tube sterile, pyrogenic free, latex free, single use, vascular catheter 5fr/16g, double lumen length 50cm.usfda/four digit notified ce approved. should have two guide wire 45 cm & 80cm or more(logline iv.) peel-away sheath glide thru 5fr *10 cm, guide wire nitinol 80 cm, guide wire nitinol 45 cm, introducer needle 21 g *7 cm,syringe-10 ml luer-lock, skin protectant prep pad, second site adjustable hub, measuring tape,5 fr pressure injectable picc line with blue flex tip 50 cm, dressing statloock stabilization device , vascular catheter 5fr/16g, double lumen length 55cm.usfda/ four digit notified ce approved, should have two guide wire 45cm & 80cm or more (logline iv.) peel-away sheath glide thru 5fr *10 cm,guide wire nitinol 80 cm,guide wire nitinol 45 cm,introducer needle 21 g*7 cm, syringe-10 ml luer-lock, skin protectant prep pad, second site adjustable hub, measuring tape,5 fr pressure injectable picc line with blue flex tip 55cm, dressing statloock stabilization device (suture less), vascular catheter with metal guide wire,5fr triple lumen, size range 55cm or more (logline iv:)usfda/four digit notified ce approvedsyringe 12 ml, internal stylet, measuring tape, stat lock catheter stabilization device (suture less), introducer safety peripheral iv catheter 20g,micro introducer with vessel dilator, guide wire-50 cm nitinol, needle introducer 21 g, safety scalpel,end cap, "core biopsy instrument with compatible co-axial needle (automatic disposal ) should be bevel tip.should have adjustable penetration depth of 18mm and 25 mm with automatic and semi- automatic firing modes in single instrument/gun.should have fire ready indicator to reduce the risk of premature instrument firing.should have advanced echogenic technology for enhanced visibility in ultrasound.should be available with compatible coaxial needle in a single kit. instrument / gun size: 18 gauge, 16cm with coaxial needle size: 17gauge, total cannula length 12.9cm.", disposable bone marrow biopsy needleshould have ergonomic two- piece t-handle design.should have trocar tapered stylet point for easy coring of bone.should have triple crown cannula tip with 6 cutting cannula facets.should be available with marrow acquisition cradle with sample size verification marking.11gauge, 4 inch length", "absorbable surgical suture (synthetic)antibacterial coated sterilised needled suture (braided coated polyglactin/ polyglycolic acid violet) 1/2 circle ct round bodied40mm, gs needle, suture length 90 cm", bed side leucodepletion filters for blood transfusion (for 2 u
Tender For supply of implants /pacemaker /accessories, on rate contract basis - single chamber, ssi, ssir, ssir (paediatrics), ssi mri compatible, ssir mri compatible, vdd/vddr, dual chamber, ddd, dddr, ddd (mri compatible), dddr (mri compatible), dddr ( with at/af management), biventricular pacemakers(crt devices)-crt-p/crt-d, crt-p, crt-p advanced, crt-d, crt-d advanced, crt-d (mri conditional), crt-d (with only lv pacing option), crt-d (with only lv pacing option; mri conditional), "biventricular pacemaker with atrial , rv, quadripolar lv leads and all accessories (mri compatible)", "biventricular pacemaker with atrial , rv, quadripolar lv leads and all accessories(mri compatible)-advanced", icd , single chamber (icds), single chamber (icds)-advanced, single chamber (mri icds), dual chamber (icdd), dual chamber (mri icdd), icd ( with at/af diagnosis), biventricular pacemaker + icd (combo device), biventricular pacemaker + icd (combo device) with atrial , rv, bipolar lv leads, biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible ), advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible), leadless pacemaker, implantable loop recorder, implantable loop recorder <1.5cc, ssir mri compatible advanced, dddr mri compatible - advanced, single chamber (mri icds) with bluetooth feature, single chamber (mri icds) with bluetooth and advanced features, dual chamber (mri icds) with bluetooth feature, dual chamber (mri icds) with bluetooth and advanced features, advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible) with bluetooth connectivity, advanced biventricular pacemaker + icd (combo device) with atrial, rv, quadripolar lv leads (mri compatible) with bluetooth connectivity and multipoint pacing, single chamber rate responsive pacemaker -1, single chamber rate responsive pacemaker -2, double chamber rate responsive pacemaker - 3, double chamber rate responsive pacemaker - 4, dx icd , sicd - lead less single chamber icd. it is a propritory product for boston scientific with 8 years longevity and 81 jule deliverable energy specially indicated for patients who are diabetic, more prone for infection, young patients etc., " conduction system pacing - pre-shaped catheter for conduction system pacing compatible with routine active fixation pacing lead.• catheter should be able to deliver all active pacing fixation, stylet driven extendable helix leads with diameter of 6fr or below.• multiple options of shape availability for various anatomies.• catheter should have integrated hemostasis valve along with facility of contrast injection port.• atraumatic radiopaque tip to facilitate imaging under fluoroscopy.• catheter should have outer diameter of 9fr or less.• should be supplied with compatible 0 .035” guidewire and slitter.• helix locking tool (hlt) along with the catheter provides alternative to the clip – on tool used for retracting /extending of helix."
Tender For corrigendum : t. e. no - gmscl/d-773 /rc/2025-26 (on rate contract basis) surgical item (57 item) - disposable hypodermic needle size: 22x1", 297700, stainless steel, with needle cap, single use, size: 23x1", disposable hypodermic needle size: 24x1", 380500, stainless steel, with needle cap, single use size:24 x 1.5", disposable syringe 10 ml (without needle), 2003800, sterile single use syringes as per, sterile hypodermic syringe for single use size:5 ml (without needle), 1733900, length: 100 cm diameter: 2non biolable catgut chromic needle :1/2 circle round body 45 mm heavy, absorbable surgical suture polyglactin 910 {synthetic}with needle 1 with 1/2cir rb 40 mm, 428400, stainless steel, with needle cap, single use, size: 26x0.5", disposable spinal needle 22g x 3 .5" inch, 35300, stainless steel, single use,size 25g x 3.5", disposable spinal needle 23 g x 3.5", 218100, length : 90cms. diameter :1 triclosan coated polyglactin 910 1/2 circle rb 30-40 mm, permeable non woven surgical synthetic adhesive tape (non sterile). size: 1.25 cms x 9.1 meter, 117600, non toxic. non pyrogenicclosed distal end coned withradio-opaque material foraccurate placementsoft, frosted and kinkresistant pvc tubing,sterile by eto ,color coded funnel end connector for easy identification of size., ryles tube(eto sterilized),size-10., 7600, non toxic. non pyrogenicclosed distal end coned withradio-opaque material foraccurate placementsoft, frosted and kinkresistant pvc tubing,sterile by eto ,color coded funnel end connector for easy identification of size, combined spinal/epidural mini pack and needle set containing 18 g epidural mini pack and 26 g lancet tip spinal, 269000, 1) double lumen central venous indwelling catheter : polyurethane radio opaque with a soft tip,size- 7 f: 16 g/16 g. length 15 cm, 20 cm 2) introducer needle:y needle with check valve to provide a second port 3) guide wire :j- tip, kink resistance, soft tip, resilient, with length markings 4) scalpel5) dilator 6) catheter holder for fixation 7)fully transparent extension line with colour coded hub with white slide clamp, air tight closure at injection port 8)injection cap 9) must have sterile dressing, pigtail catheter with needle size -14 f, 54700, iso 13485 as amended from time to timepigtail catheter set for dranage.size of needle-:16 f with guide wire diameter of 0.046".length-:35-40 cm appox,cathater material-:tpu.troccar needle-:stainness steel.trocar stylet-:stainness steel. cathater introduction stiffening canula -1,multihole drainage cathater-1., insulin syringes - 40 iu, 241100, haemostatic sponge in surgical procedure pharma grade, pure gelatin size-8x3 cm, monofilament polyamide black (non absorbable) 38 mm ,10/0 (0.2 metric), sterilized surgical needle suture ,with needle suture, with two needles (double arm) spatulated 6 mm, 3/8 circle needle, 38300, polyglactin 910- 4 inch/10 cm ,10/0(0.2 metric),sterilized surgical needle suture, with needle spatulated 6 mm,3/8 circle needle, double lumen central venous cathater size : 9 f 13 g/13 g length 15 cm 20 cm, 192200, iso 13485 as amended from time to time tube size : 28 fr bag capacity : 2000 ml specially designed kit for post-operative abdominal drainage consists of super smooth rainage catheter along with a collection bag.made from non-toxic and non- irritant medical grade pvc.provided with specialised foldable handle which holds the tube upright prevents accidental kinking during handling & suitable for bedside hanging.soft & smooth catheter with large atraumatic eyes for efficient drainage.radio-opaque line throughout catheter length help x-ray visualization.catheter is color coded for instant size identification.sterile individually packed in peelable pouch.unit consists of : soft drainage catheter 50 cm long collection bag of 2000 ml capacity. transparent with volume measurement marking., pvc abdominal drain kit no 32 fr, 61700, iso 13485 as amended from time to time10 x 10 cm collagen sheet should be 100 per
Tender For tender for the supply of 24 medical devices under package-23 for various health institutions across karnataka under annual indent 2025-26 - sterile disposable syringes with hypodermic needle with 1.5 inch luer lock 2.5ml-26 g 1x1, foleys catheter with bulb 18f ,three way 1x1, urethral catheter 3fr 70 cm open end 1x1, foleys catheter with bulb 12f 1x1, foleys catheter with bulb 6f 1x1, sterile hypodermic needle for single use 23 g 1x1, foleys catheter with bulb 14f 1x1, urine collection- bag with valve out-let 2liters capacity 1x1, epidural minipack 18g 80mm 90mm metal stylet for single use only, sterile 1x1, nitrile examination sterile gloves7 1x1, n95 mask na 1x1, urine collection bag with valve out-let. 1.5liters capacity 1x1, ultrasound gel na 1x 250 ml, surgical blade 23 1x1, surgical blade 22 1x1, surgical blade 15 1x1, surgical blade 11 1x1, sterile single-use insulin syringes (100 unit) with needle(26g ) 1x1, sterile disposable syringes with hypodermic needle 2ml-22g 1x1, sterile disposable syringes with hypodermic needle 1ml -26g 1/2 needle 1ml-26g 1x1, sterile disposable (single use) ptfe i.v. cannula with integrated 3 way stop cock. size 26g 1x1, sterile disposable (single use) ptfe i.v. cannula with integrated 3 way stop cock. size 24 g 1x1, ecg gel na 1x250 ml bottle/tube, blood transfusion set with filter 170 micron1x1