Get complete information related to latest Ventilating Fan Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ventilating Fan Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ventilating Fan Tenders.
Tender For supply of air circulator type electric fan and regulator (v2) conforming to is 2997 (q2) , propeller type ac ventilatingfans (exhaust fan) (v3) conforming to is 2312 (q2)
Tender For supply of spares for repair of cooling towers girt , do - but girt 14 0x1 58 x 5 5 8 , do-- but, girt 12 x 4 x 3 , do-- but stair wooden planks with 32 , do-- but stair steps 9 x 1-1 2 x 32 , pvc c type drift eliminator with supporting clamps , splash bar pvc u bar 4 long , stainless steel materials ss bolt with one nut 9 1 2long , stainless steel materials ss bolt with one nut 9 long , stainless steel materials ss bolt with one nut -5 1 2 long , stainless steel materials ss bolt with one nut 8 long , stainless steel materials ss bolt with one nut 8 1 2 long , p p ring 70 75 mm size od , frp corrugated sheets 3 00 mtr , cooling tower structure girt 10 , cooling tower structure girt 8 , cooling tower structure girt 12 , cooling tower structure girt 12 0 , cooling tower structure column 15 , cooling tower structure column 12 0 , cooling tower structure- column 10 , cooling tower structure diagnals 7 , fan deck floor 8 , hotwater distribution floor members without hole , hotwater distribution floor members with standard hole , cooling tower structure except newzeland radiate pine basin seal 8 , cooling tower structure except new zeland radiate pine basin side 12 , cooling tower structure except new zeland radiate pine basin end 10 , cooling tower structureexcept new zeland radiate pine basin end 8 -0 , cooling tower structure except new zeland radiate pine eliminator blade 6 , chemical treated pine wood timber , eliminator frame plywood 1st pass 13 long , materials made of marine plywood , grid support 4 , eliminator wire of 1 3 long , screw shank nails 3 long , screw shank nails 2 long , screw shank nails 1 long , ss bolt with one nut 8 1 2 long , ss bolt with one nut 6 long , ss bolt with one nut 5 long , ss bolt with one nut 8 long , ss bolt with one nut 7 long , ss bolt with one nut 4 long , ss bolt with one nut 7 1 2 long , ss bolt with one nut 5 long , ss washer standard cut 12mm , ss washer standard for 3 8 dia bolt , ss washer 2mm appx thick 3 , spiral target nozzle , p. p. ring small size black , mastic compound , marine plywood bwr grade as is , frp corrogated sheets 1 25 mtr , corrugated ac fc sheet louvers 6mm , labour rate for replacement of existing wooden , labour rate for replacement of top deck , labour rate for repair rectification replacement of main wooden , main structure of cooling tower cells staircases by removing , cooling towers from top deck to water distribution platform , wooden supports and ss hardware and replacing the same
Tender For supply of set of spares for pct of cob10 -complete set of cooling tower pvc fills, drift eliminators, nozzles and all alliedspares (excluding id fan and its drive assembly) for refurbishing each cell of primarycooling tower of cob #10. details of each cell of cooling tower- water inlet flow350-400 m3/hr, water inlet temp- 55 deg c, water outlet temp- 4 deg c above wet bulbtemperature. application of supplied material. other details as per annexurecob10/pct/fills/001.
Tender For scope of work (sow) as mentioned in tender and schedule of work( 13 )items as given below ,[1] maint of cooling water pump,cas 8.000 ea,[2] maintenance of valves of cas 12.000 ea,[3] assyg,pump 4.000 set,[4] maint of air filter 12.000 set,[5] chkg,alignment of pump&mtr 4.000 ea,[6] rprg,intercooler 2.000 ea,[7] chang/servicng after cooler/intercoolers 2.000 set,[8] svcg,airline vlv 13.000 ea,[9] checking pump motor allignment,cas 4.000 ea,[10] maint of duplex filter 4.000 ea,[11] maint of starting air compressor. 4.000 ea,[12] maint of cooling tower gear box. 2.000 ea,[13] maint of cooling tower fan. 2.000 ea