Tender For supply, termination installation, testing and commissioning of ventilation system on roof of paint shop of lower parel workshop along with complete installation, frame work of suitable size with ms 50mmx 50 mmx 5mm, cabling, cable try work, wiring and protection system with 4 pole 20a mcb for each and mcb board along with 2.5 sqmm cable 4 core and 10 sqmm cable from panel to distribution board for main supply and power full exhaust system of length and height minimum 1 meter with width minimum 400 mm, diameter blades 900 mm, blades rotational speed -620 r/min or more. air flow 30,000 m?/h, noise level shall be less than 70 db, power shall be minimum 750 watt with the flap system and motor starter of 1 hp or as per suitable and confirming to s/iec 60947-4-1 or latest. all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt i) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]
Tender For reer tender notice - purchase of non consumable item in thermal lab for mechanical department - open type air conditioning system kitcode - (d030)1.5 ton1. compressor type:open type capacity:0.5 tr to 1tr power 1 hp supply 230 v,single phase 50 hz2.condenser type: air cooled condenser material : copper tube with aluminium fins fan motor:230 v ac3.evaporator type :open fin type material : copper air circulation : blower assisted mounted openly for observation4. blower/fan type: centrifugal blower air flow : adjustable power:230 v ac5. refrigeration type : r226. measuring instruments pressure gauges: low&high pressure temperature:thermometers,digital sensors voltmeter : 0 to 300 v ammeter : 0 to 10 a temperature display : at inlet and outlet points energy meter: single phase, exhaust gas analysercode - (d037)to find the percentage of co,co2, o2, amount of hc and nox using exhaust gas analyzer. afr and lammda are measurable.
Tender For supply of mechanical lab items - furniture, crdi system demonstration board working with motorized. specification: fuel supply system diesel crdi type (actual working model with electronic ignition system), inlet manifold,throttle body with acceleration position sensor, fuel common rail, fuel injectors, fuel tank, fuel filter, fuel tank module (fuel pump), pressure relief valve, pressure gauge, ecu, electronic delco with distributor (powered by 12v motor or camshaft), ignition coil, spark plugs, power supply 12v / 10 amps, fuel level gauge & control panel,ignition key for on/off system, mpfi system demonstration board working with motorized. specification: fuel supply system petrol mpfi type (actual working model with electronic ignition system), inlet manifold,throttle body with acceleration position sensor, fuel common rail, fuel injectors, fuel tank, fuel filter, fuel tank module (fuel pump), pressure relief valve, pressure gauge, ecu, electronic delco with distributor (powered by 12v motor or camshaft), ignition coil, spark plugs, power supply 12v / 10 amps, fuel level gauge & control panel,ignition key for on/off system, exhaust gas analyser specification: to find the percentage of co, co2, o2 and amount of hc, nox in exhaust gas. *operating temperature: 0 to 50 degree celcius*measuring gas intake ; 1 litre per minute*reposnse time : 5 sec
Tender For purchase of non consumable item in thermal lab for mechanical department - open type air conditioning system kitcode - (d030)1.5 ton1. compressor type:open type capacity:0.5 tr to 1tr power 1 hp supply 230 v,single phase 50 hz2.condenser type: air cooled condenser material : copper tube with aluminium fins fan motor:230 v ac3.evaporator type :open fin type material : copper air circulation : blower assisted mounted openly for observation4. blower/fan type: centrifugal blower air flow : adjustable power:230 v ac5. refrigeration type : r226. measuring instruments pressure gauges: low&high pressure temperature:thermometers,digital sensors voltmeter : 0 to 300 v ammeter : 0 to 10 a temperature display : at inlet and outlet points energy meter: single phase, exhaust gas analysercode - (d037)to find the percentage of co,co2, o2, amount of hc and nox using exhaust gas analyzer. afr and lammda are measurable.
Tender For corrigendum : supply, installation, testing and commissioning of exhaust system for airbag deployment area pedestrian safety lab (psl) at icat centre-ii manesar (haryana)
Tender For corrigendum : supply of laboratory furniture d d - wall bench ,wb - 1, size l 2025 mm x w 600 mm x h 900 mm , over head storage cabinet with frame structure size l 645 mm x w 350 mm x h 635 mm , corner bench ,cb - 1, size l 1030 mm x w 0900 mm x h 900 mm , wall bench ,wb - 2, size l 1525 mm x w 750 mm x h 900 mm , over head storage cabinet size l 720 mm x w 350 mm x h 635 mm , chemical storage cabinet ,csc, size l 750 x d 450 x h 2100 mm , wall bench ,wb - 3, size l 1525 mm x w 750 mm x h 900 mm , island bench ,ib - 1, size l 1550 mm x w 1500 mm x h 900 mm , wall mounted storage cabinet with frame structure size l 630 mm x w 350 mm x h 635 mm , low constant volume, lcv, type bench fume hood, size l 1800 x d 915 x h 2300 mm, for ac lab, , low constant volume, lcv, type bench fume hood, size l 1500 x d 915 x h 2300 mm, for ac lab , exhaust fan - one fan for 2 nos. 1800 mm, 1 nos. 1500 mm wide fume hood and 1 no. chemical storage cabinet , wall bench ,wb - 1, size l 4500 mm x w 750 mm x h 900 mm , wall mounted storage cabinet with frame structure size l 720 mm x w 350 mm x h 635 mm , wall bench ,wb - 1, size l 2800 mm x w 900 mm x h 900 mm , wall mounted storage cabinet with frame structure size l 670 mm x w 400 mm x h 600 mm , wall bench ,wb - 2, size l 2793 mm x w 750 mm x h 750 mm , over head storage cabinet size l 720 mm x w 400 mm x h 600 mm , low constant volume ,lcv, type bench fume hood,size l 1800 x d 915 x h 2300 mm, ,for ac lab, , exhaust fan - 1 nos. 1800 mm wide fume hood , low constant volume, lcv, type bench fume hood, size l 1800 x d 915 x h 2300 mm, for ac lab , exhaust fan - one fan for 2 nos. 1800 mm wide fume hood , wall bench ,wb - 1, size l 0800 mm x w 915 mm x h 900 mm , wall bench ,wb - 1, size l 7550 mm x w 750 mm x h 900 mm , wall bench ,wb - 2, size l 2050 mm x w 750 mm x h 900 mm , island bench ,ib - 1, size l 6800 mm x w 1500 mm x h 900 mm , chemical storage cabinet ,csc, size l 1000 x d 450 x h 1830mm , chemical storage cabinet ,csc, size l 1000 x d 450 x h 1830mm without exhaust system , wall bench ,wb - 3, size l 1775 mm x w 900 mm x h 750 mm , low constant volume ,lcv, type bench fume hood,size l 1500 x d 915 x h 2300 mm, ,for ac lab, , exhaust fan - one fan for 2 nos. 1500 mm wide fume hoods and 2 nos. chemical storage cabinets , wall bench ,wb - 4, size l 6800 mm x w 750 mm x h 900 mm , exhaust ducting in pp frp, round shape, construction, 3mm, 2mm, complete with necessary bends, reducers, t connections, supports, flanges, gaskets, nutbolts etc. , additional requirement the vendor has to shift and reinstall the furniture of items 1 to 25 of the paloura campus whenever the new academic block is ready at the main campus jagti , lab stools