Web Analytics Made Easy - StatCounter

Venturi Flume Tenders

Get complete information related to latest Venturi Flume Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Venturi Flume Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Venturi Flume Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39116726 Due date: 24 Feb, 202524 Feb, 2025 NA
Tender For supply and installation measuring instrument ai (artificial intelligence) ohe stagger and height measurement system as per the rdso number ti/spc/ohe/mri/0142 or latest. [ warranty per iod: 30 months after the date of delivery ]

CTN :39101612 Due date: 06 Feb, 202506 Feb, 2025 NA
Tender For supply of bluetooth enabled measurement instrument as per annexure- a

CTN :39065456 Due date: 12 Feb, 202512 Feb, 2025 NA
Tender For lab equipment - laying and jointing pvc pipe. heading, bi- quartz polorimeter appratus, newtons ring appratus, spectrometer, light emitting diode appratus, band gap of semiconductor appratus, measurement of wavelength of he-ne laser using rular with laser complete setup, fridge, trinocular microscope, hluminating globle dimensional physical, abnly level, aerial photographs, anemometer, aneroid barometer, apparatus day and night, digital toposheet, dry and wet bulb thurmometer, earth layer model, fortins barometer, geomorphics models, hygrometer, led tracing table, maximum & minimum thermometer, model of solar system, models of geographical terms, maximum & minimum thermometer, phases of moon, photo of great geographics, relief raised maps of all continents india & madhya pradesh, satellite imageries, wall thermometer, weather maps, windvane, relief maps of india, set of 100 geomorphological models showing landforms of river glaciers,volcanoes,desert,oceans,underground water etc., set of 100 rocks forming minerals, set of 100 rocks, set of 100 thin section og igneous,sendimentary & metamorphic rocks, set of 25 non metalic for industrial use, stereo pair(aerial photography), top sheets(survey of india), electronic dissolve oxygen meter, digital calorimeter, aquqsal digitalph tds meter, digital falme photometer, digital polaimeter, infrared thermometer, poalrography, ppe kit, bp instrument, hemoxytometer, hemogloben meter

CTN :38940732 Due date: 03 Feb, 202503 Feb, 2025 58.00 Lacs
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - rota-evaporator the rota-vapour should have a vertical condenser for standard applications with cooling surface area of 1500 cm2 or better with a protection class of ip20 or better. the rotation speed of the instrument should be 20-280 rpm or better. the water bath should have controlled temperature range of heating within a range of 0-90oc or better with a capacity to accommodate evaporating flask from 50-4000 ml with same joint. all glass components should be made of borosilicate 3.3 glass. digital interface of 4 inches or better to facilitate monitoring of temperature, speed and vaccum. there should be a provision of power cut off when actual temperature exceeds set temperature or by rapid temperature increase. the system should have timer function to regulate the time of the process and automatic aeration when pressure reaches above 1400 mbar. the entire system should have ce/csa approvals. the vaccum pump should be made up of chemically resistant ptfe diaphragm vacuum pump with a suction capacity of 1.5m3/h or better with 2(2) number of steps(heads). the final vaccum should be 7-10 mbar. the recirculating chiller should be of 3l capacity with a working temperature range of room temperature to -10oc and a cooling capacity of 500 w at 15oc., ft-irthe ftir instrument should have transmission interface which provides classic infrared sampling for the measurement of solids, liquids or gases. the transmission module is purgeable and preferable to come with a standard cardholder. the scan range should be from 8000-350 cm-1 with a spectral resolution of 0.5cm-1 or better. the signal to noise ratio: 35000:1 or better. the system should have michelson type/ rock solid/self-compensating, dynamically aligned interferometer which removes any tilt and shear scanning error with 10 years warranty on interferometer. the system should have temperature stabilized or dtgs detector/ temperature control dlatgs detector. kbr/ znse beam splitter to meet complete spectral range. the system should be operable through a windows 10 compatible software with self-diagnostic after initialization, provision for creation of library. the software should have spectral, peak and text search function. the software should be capable of comparing spectrum, quantification and photometric data. there should be a provision of digital humidity level monitoring in internal optics through software and customized template. the system should be supplied with following accessories.hydraulic press for kbr pellet preparation software recognize diamond atr accessory with force monitoring for quick analysis of different sample) solid, liquid, paste and gels) of food, raw material, packaging material etc.installation, familiarization at installationpccorei5, 4gb ram, 1 tb hdd, 18.5 led/lcd, windows 10 , uv visible spectrometer microprocessor based wavelength range: 190 to 1100 nm with 7-8 inch led display. the system must have pre-programmed methods for water parameters which should be compatible with available reagents for the water testing. system should be true double beam uv-visible spectrophotometer with 8-cell changer the monochromator should be blazed czerny-turner type with 1200 lines/nm blazed grating. the detector should have si-diodes/ccd. system should have wavelength range from 190 to 1100 nm or better system spectral bandwidth should be 1 nm (190 to 1100 nm) wavelength setting should be 0.05 nm wavelength accuracy should be 0.3 nm wavelength repeatability should be 0.1 nm or better scan speed max 6,000 nm/min or better photometric range absorbance : -4 to 4 abs transmittance range should be : 0 % to 400 % photometric accuracy should be less than 0.005 abs at 1.0 abs light source tungsten halogen lamp & deuterium lamp photometric repeatability 0.0002 at 0.5 abs baseline stability: 0.0003 abs/h operating system (os): system should have to

CTN :39067030 Due date: 13 Feb, 202513 Feb, 2025 NA
Tender For supply of dispensary storage racks , reception counter , chairs , portable washroom with fittings , generator shed , 63 kva generator , cable and wiring with elect fittings , tvs 65 inch , tvs 55 inch , tata sky , water supply pump , water syntax 5000 liter , water syntax 2000 liter , geysers 01 each for ward, toilet and kitchen , elect water dispensers , kero heaters , computer i5 8th gen 8 gb ram 1tb hdd 20 inch display with mouse and keyboard , wheel chairs , blankets quilts , patient round chair , tables 4ftx2ft , revolving office chairs for staff , steel benches 3 seater , plastic chairs waiting room , information medical boards , hamam 500 liter , digital boards 15ft x 2ft , sign boards , distemper and maintenance , nebuliser machine , bp machine digital , bp machine manual , pulse oxymeter , suturing tray kit , needle destroyer , weighing machines , ht measurement instrument , oxygen cylinder 1000 liter , oxygen cylinder 400 liter , refillable portable oxygen cylinder 10 liter , foldable stretchers , thermometer digital , electric blankets single bed , multipara monitor , automated external defibrillator , high low patient bed , auto clave sterilizer , bmw dustbin set of 3 , wet and dry dustbins , crash cart trolley , patient trolley , guedel airway , intubating video laryngoscope , endo tracheal tube no 06 , endo tracheal tube no 07 , catheter tray , eye test drum near vision , eye test drum distant vision , minor ot light , spinal upper limb , cervical collars sp , oxygen concentrator , masks , surgical gloves , ecg machines , glucometer , hb meter , hb testing strips , torch , examine table , stethoscope , fluid warmer , hapo bag , suction apparatus , sheet water proof , tourniquet , thomas knee splint , intercostal drainage tube , infusion warming sys , pressure infusion bags , vein finding devices , refraction unit , infusion pump , laryngeal mask airways

Central Government/Public Sector

CTN :39007294 Due date: 10 Feb, 202510 Feb, 2025 NA
Tender For laboratory ( part-1 of 2 ) - anti b blood gr.serum (monoclonal)unit of 5 ml bulb, 1 unit, 4, elisa reader instrument should have a windows-based operating system., instument should be compatible with u, v and flat microwell strips., instrument should have up to100 programmable locations for different parameters., instrument should have 8 independent channel optical systems., instument should have programmable speed and time for plate shaking., instument should take five seconds to measure the entire plate., instument should have option to run 12 assays in one plate, instument should have 4 preinstalled filters and option to upgrade 4 optional filters., measuring range of the instrument should be 0.000 to 4.000., instument should have a resolution of 0.0001 od., system should have option for external printer., the system should have single and dual wavelength measurement options., system should have specific dedicated information management software., system should have unlimited results storage facility., systemshould have facility for plate templets. plate templets must allow positioning of control, calibrators, blanks, and samples at any location on the plate with lab custom patient ids and names., the system should have qc programme facilities with west-guard rule.,, 1 unit, 8, 0.1 n hclready to use for hemoglobin estimation by sahlis method stablear/gr/sxcellar quality with all assay details, 1 unit, 12, 3 cell panel for antibody screening - a panel of 3percentage reagent red blood cells for quality control of anti-human globulin procedure (coombs control cells), pack size should be of 2 ml each., company should provide qc report with each vial supplied., 60 t, 16, a.p.t.t.ready to use stable reagents method mechanical/manual clot detection systems diagnos aptt reagent calcium chloride (0.02 mol/l) tsc solution, 5ml, 20, abl90 flex solution pack (680) abl 90 radiometer, 1 unit, 24, ace (angiotensin converting enzyme) pack for diasysfully automatic biochemistry, 5litre/pack, 28, actin (10 x 10ml) fully automatic cougulation analyser cs-2400, 1 unit, 32, actin fsl (10x10ml) fully automatic cougulation analyser cs-2400, 1 unit, 36, ada eco for diasys, 1 unit, 40, agar agar powderdehydrated powder, 1 unit, 44, alat (gpt) fs (ifcc mod.) syspack sys for diasys fully automatic biochemistry sys, 4 x 25 ml, 48, albumin bcg eco for diasys, 4 x 32 ml, anti b blood gr.serum (monoclonal)unit of 5 ml bulb, 1 unit, 4, elisa reader instrument should have a windows-based operating system., instument should be compatible with u, v and flat microwell strips., instrument should have up to100 programmable locations for different parameters., instrument should have 8 independent channel optical systems., instument should have programmable speed and time for plate shaking., instument should take five seconds to measure the entire plate., instument should have option to run 12 assays in one plate, instument should have 4 preinstalled filters and option to upgrade 4 optional filters., measuring range of the instrument should be 0.000 to 4.000., instument should have a resolution of 0.0001 od., system should have option for external printer., the system should have single and dual wavelength measurement options., system should have specific dedicated information management software., system should have unlimited results storage facility., systemshould have facility for plate templets. plate templets must allow positioning of control, calibrators, blanks, and samples at any location on the plate with lab custom patient ids and names., the system should have qc programme facilities with west-guard rule.,, 1 unit, 8, 0.1 n hclready to use for hemoglobin estimation by sahlis method stablear/gr/sxcellar quality with all assay details, 1 unit, 12, 3 cell panel for antibody screening - a panel of 3percentage reagent red blood cells for quality control of anti-human globulin procedure (coombs control cells), pack size should be of 2 ml each., company shoul

Central Government And Public Sector

CTN :38960306 Due date: 05 Feb, 202505 Feb, 2025 NA
Tender For wheel diameter gauge with digital display for measurement of wheel in both mounted (in-sui t) and un-wanted wheels of coaches during maintenance. the gauge given direct reading on a digital displa y. detailed specifications of item : 1. measuring range : 600 to 1200 mm, 2. applicability : bg wheel, 3. lea st count : 0.1 mm, 4. measuring accuracy : plus/minus 0.3 mm (for thread with surface finish n7 to n8 or b etter) & plus/minus 1.5 mm (for tread with surface finish n9 to n11 or better), 5. recording of reading : to be provided, 6. display: buli in led, 7. weight : 750 gms (approx.), 8. power supply : inbuilt rechargeable b attery &battery charger. warranty certificate & product manual to be supplied along with the instrument. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up