Get complete information related to latest Vertical Pump Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vertical Pump Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vertical Pump Repair Tenders.
Tender For tender for supply of spares for 33 kv vaccum circuit breaker - spring charging motor 220 v dc , contactor 95x for 33kv vcb breaker type vm 36 , anti pumping relay for 33kv vcb breaker type vm 36 , lr switch for 33kv vcb breaker type vm 36 , closing tripping coil 220 v dc drg no 25211001563 009 , closing unit assembly part no 35211001919 v00 , limit switches test service positions for 33 kv vcb
Tender For producing potable water as desirable standards from malekpur main head works of hindoliya regional water supply scheme by proper operation and maintenance of conventional water treatment plant at malekpur mhw including all civil works, pipe system channels, all consumable, incl. proper chlorination, skilled and unskilled manpower, material, t & p articles, vehicles, all type of valve chamber, and water meter for continuous running of filter plants round the clock, with uninterrupted pumping of treated water from malekpur main head works to various sub headworks. proper operation and maintenance of different class, type and diameter pipes, pump houses, sumps, rcc esr/stand pipes, sluice valves, non return valve. at all these head works. replacement spares all equipments and maintenance of civil structures etc. including supply sufficient potable water to villages included in the scheme with residual chlorine of required ppm at bulk supply point including all type of brake down works for civil works. providing sufficient no. of supervision skilled and unskilled labours and providing security for all head works sites, pipeline etc for overall management of o&m work of whole scheme based on mahi river for 70 villages and their habitation for 24 hours for 5 months periods. (without pumping machinery)
Tender For supply of spares field switch of be1800e shovel c c > f> f - shunt trip coil assly 110v dc part no fsb0001 , electric closing coil assly 110v part no fsb0002 , h t c t class 1 point 0 5p 10 part nofsb0040 , core balance transformer lt part nofsb0046 , auxiliary contactor part nofsb0049 , pilot relay 110v dc part no fsb0051 , push button part no fsb0054 , limit switch part no fsb0057 , earth leakage relay 110v wire door mountd part no fsb0062 , complete vcb assembly part no fsb0063 , 6 6kv 3 3kv 110v 3ph 2 point 5kva transformer part no fsb0066 , lt fuse for control circuit part no fsb0083 , hrc fuse for pt ht side part no fsb0084 , hrc fuse for pt lt side part no fsb0085 , timer part no fsb0087 , limit switch part no fsb0088 , over voltage relay part no fsb0107 , under voltage relay part no fsb0108 , push to trip knob part no fsb0109 , ground check relay part no fsb0112 , time delay relay part no fsb0113 , anti pumping contactor part no fsb0115
Tender For corrigendum : supply of switchgear spares for servilink make battery charger installed at ssnnl saurastra branch canal pumping station,surendranagar. - ac mains power contactor (con-1) 32 amp for servilink make 90a battery charger, aux contact block for ac mains power contactor (con-1) for servilink make 90a battery charger, spare coil for ac mains power contactor (con-1) for servilink make 90a battery charger, thermal overload relay (o/l-1) 17 to 25 amp for ac mains for servilink make 90a battery charger, ac auxi. contactor (con-3/4) 415 v ac coil for servilink make 90a battery charger, dc power contactor (con-2) 115 amp with 110 v dc coil for servilink make 90a battery charger, aux contact block for dc power contactor (con-2) for servilink make 90a battery charger, spare coil for dc power contactor (con-2) for servilink make 90a battery charger, 32 amp 3pole on/off type mccb (mccb1)ac i/p isolation for servilink make 90a battery charger, 1c/o auxillary contact for mccb (mccb1)ac i/p isolation for servilink make 90a battery charger, 100 amp 3pole on/off type mccb(mccb2)dc o/p isolation for servilink make 90a battery charger, ac mains power contactor (con-1) 40 amp for servilink make 125a battery charger, aux contact block for ac mains power contactor (con-1) for servilink make 125a battery charger, spare coil for ac mains power contactor (con-1) for servilink make 125a battery charger, thermal overload relay (o/l-1) 28 to 40 amp for ac mains for servilink make 125a battery charger, ac auxi. contactor (con-3/4) 415 v ac coil for servilink make 125a battery charger, dc power contactor (con-2) 115 amp with 110 v dc coil for servilink make 125a battery charger, aux contact block for dc power contactor (con-2) for servilink make 125a battery charger, spare coil for dc power contactor (con-2) for servilink make 125a battery charger, 40 amp 3pole on/off type mccb (mccb1)ac i/p isolation for servilink make 125a battery charger, 1c/o auxillary contact for mccb (mccb1)ac i/p isolation for servilink make 125a battery charger, 160 amp 3pole on/off type mccb(mccb2)dc o/p isolation for servilink make 125a battery charger, ac mains power contactor (con-1) 32 amp for servilink make 90a battery charger, aux contact block for ac mains power contactor (con-1) for servilink make 90a battery charger, spare coil for ac mains power contactor (con-1) for servilink make 90a battery charger, thermal overload relay (o/l-1) 17 to 25 amp for ac mains for servilink make 90a battery charger, ac auxi. contactor (con-3/4) 415 v ac coil for servilink make 90a battery charger, dc power contactor (con-2) 115 amp with 110 v dc coil for servilink make 90a battery charger, aux contact block for dc power contactor (con-2) for servilink make 90a battery charger, spare coil for dc power contactor (con-2) for servilink make 90a battery charger, 32 amp 3pole on/off type mccb (mccb1)ac i/p isolation for servilink make 90a battery charger, 1c/o auxillary contact for mccb (mccb1)ac i/p isolation for servilink make 90a battery charger, 100 amp 3pole on/off type mccb(mccb2)dc o/p isolation for servilink make 90a battery charger, ac mains power contactor (con-1) 40 amp for servilink make 125a battery charger, aux contact block for ac mains power contactor (con-1) for servilink make 125a battery charger, spare coil for ac mains power contactor (con-1) for servilink make 125a battery charger, thermal overload relay (o/l-1) 28 to 40 amp for ac mains for servilink make 125a battery charger, ac auxi. contactor (con-3/4) 415 v ac coil for servilink make 125a battery charger, dc power contactor (con-2) 115 amp with 110 v dc coil for servilink make 125a battery charger, aux contact block for dc power contactor (con-2) for servilink make 125a battery charger, spare coil for dc power contactor (con-2) for servilink make 125a battery charger, 40 amp 3pole on/off type mccb (mccb1)ac i/p isolation for servilink make 125a battery charger, 1c/o auxillary contact for mccb (mccb1)ac i/p isol
Tender For survey, investigation, design, supply, erection, testing and commissioning of tank filling scheme for filling 15 number of tanks, comprising of construction of barrage, in take structure, pumping machineries, 11/0.433 kv electrical sub station, transmission line rising main by lifting water from dandavathi river in soraba taluk shivamogga district including supply of spares parts & tools, operation & maintenance for five years after successful commissioning of the work for yadagoppa tank filling scheme works on turnkey basis