Get complete information related to latest Vfd Drive Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vfd Drive Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vfd Drive Tenders.
Tender For supply of injection atropine 02 ml , injection dexona 05 ml , injection adrenaline 2 ml , tablet ofloxacin 200 mg plus ornidazole 500 mg , tablet amoxycillin clavulanate 600 mg , standren v and texableed anticoagulant injuction 02 ml and 10 ml , tablet avil , tablet meloxicam 4 mg and carprofen 75 mg , spray aluspray , pre and probiotic tablets , liq povidone 100 ml , dispovan syringe 02 ml , dispovan syringe 05 ml , dispovan gloves large size , cotton bandages gauze 6 inch , cotton roll 75 or 100 gm , pow neosporin , s s set , infusion set , liq ns 100 ml , paper tape , first aid medicine box , dental paste for dogs , hair trimmer , nail cutter , ear cleaner epitic 50 ml , dental brush for dogs , shampoo erina ep or any non medicated shampoo as per handlers requirment , digital thermometer
Tender For i) combustion blower assembly with casing to model no. rd-105-hp-be-173 of m/s rdpc ma ke, or chp-40-30-1000 of m/s continental thermal make or es-cb-1025-bd of m/s eminent make make or x hp-40-30 of m/s wesman make, rated to deliver 1000 cfm at a total pressure of 40 inch wg at 70 deg. f. t he impeller shaft assy. should be both statically & dynamically balanced and mounted by means of heavy duty pillow/plummer block/ bearing block units and will be v-belt driven. appropriate anti-vibration pads a nd pipe bellows to be provided. ii)the motor connected to the blower: 30 hp, vfddriven, upto 3000 rpm, ie 2, 415v, 50hz, tefc foot mounted motor with temperature sensor at both the points. iii)warranty : the ma terial shall have a warranty of 15 months from the date of supply or 12 months from the date of fitment, w hichever comes earlier. iv) inspection and test and balancing certificate (ic) should be submitted along wit h the material supply. iv) packaging should be firm in wooden pallets to avoid damages during transportati on. [ warranty period: 15 months after the date of delivery ]
Tender For corrigendum : procurement of spares for unit 1 boiler lift for ntpc rihand - steel wire rope,1000040582,tke, pcb sm01pa/i 32 bit,1000043795,tk elev, vfddrive,1000043201,tk elev,37kw, main rope,1000053128,13mm,tk elev, main sheave,1000103597,tk elev
Tender For tender for supply of operation of water cooled centralised ac plant of 3x330 tr trane make and all associated ancillary equipments and ventilation fans etc. round the clock in 3 shifts on all days iincluding sundays and holidays by deputing supervisor , shift in-charge or skilled , semi skilled manpower etc. complete as required and as per enclosed detailed specifications. for first year , operation of water cooled centralised ac plant of 3x330 tr trane make and all associated ancillary equipments and ventilation fans etc. round the clock in 3 shifts on all days including sundays and holidays by deputing supervisor , shift in-charge or skilled , semi skilled manpower etc. complete as required and as per enclosed detailed specifications.for second year , comprehensive maintenance contract for the centralized air-conditioning system consists of 330tr water cooled chiller units (trane make)-03 nos. , chilled water pumps primary pumps (kirlosakar make)-3 nos. and secondary pump (grundfoss make)- 3 nos. with vfddrive panel , condenser water pumps (crompton make) - 3 nos. , cooling towers (advance make)-3 nos. , chilled water and condenser water lines , air handling units (floor mounted and ceiling suspended) (zeco make) with starter panels - 27 nos. power and control panels and its associated equipments like bearings , v-belts , canvas , valves (excluding the butterfly valves) , strainers , dampers , diffusers , grills , nozzles , thermostats , switchgears in control panels(excluding the power cables) , ventialation fans of toilets , electrical meters , contactors , timers etc. complete as required for smooth operation of the complete hvac system. the scope of work also includes carrying out the periodical maintenance/checking of the above equipments & maintenance of water softening plants along with supply of salt for operation as per manufacturers recommendations and/or as per the attached technical conditions. for first year , comprehensive maintenance contract for the centralized air-conditioning system consists of 330tr water cooled chiller units (trane make)-03 nos. , chilled water pumps primary pumps (kirlosakar make)-3 nos. and secondary pump (grundfoss make)- 3 nos. with vfddrive panel , condenser water pumps (crompton make) - 3 nos. , cooling towers (advance make)-3 nos. , chilled water and condenser water lines , air handling units (floor mounted and ceiling suspended) (zeco make) with starter panels - 27 nos. power and control panels and its associated equipments like bearings , v-belts , canvas , valves (excluding the butterfly valves) , strainers , dampers , diffusers , grills , nozzles , thermostats , switchgears in control panels(excluding the power cables) , ventialation fans of toilets , electrical meters , contactors , timers etc. complete as required for smooth operation of the complete hvac system. the scope of work also includes carrying out the periodical maintenance/checking of the above equipments & maintenance of water softening plants along with supply of salt for operation as per manufacturers recommendations and/or as per the attached technical conditions. for second year , painting of hvac system such as pumps , cooling tower- motors , pedastal and other equipments by removal of corrosion with sand paper and painting with corrosion resistant paint to match the adjoining areas for maintaining the equipment in good and non rusting condition. for first year , painting of hvac system such as pumps , cooling tower- motors , pedastal and other equipments by removal of corrosion with sand paper and painting with corrosion resistant paint to match the adjoining areas for maintaining the equipment in good and non rusting condition. for second year , repairing damaged insulation of exposed ac ducts by scrapping and cleaning the surface , applying cold bitumin or adhesives , supplying and fixing of 50mm thick thermo coal sheet (eps) and wraped canvas clothes with suitable self adhesive as per the specif
Tender For providing of custom bid for services - noncomprehensive annual maintenance contract for danfoss make lv vfddrives installed at nsl by oem danfoss industries private limited