Get complete information related to latest Vibration Switch Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Vibration Switch Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Vibration Switch Tenders.
Tender For supply and installation of equipments for district water testing laboratory malkangiri under rwss division, malkangiri in malkangiri district. - supply & installation of equipments for district water testing laboratory malkangiri, digital analytical balance (decimal four places):- weighing capacity: 220 g readability: 0.1 mg pan size: 90mm repeatability: + 0.1 mg linearity: + 0.2 mg adaptation to ambient conditions: by selection of 1 of 4 optimized filter levels, thermo scientific fluoride ion selective electrode (9609bnwp):-units: ppm, ion measurement mode speculations enables ion concentration measurements of monovalent, bivalent, negative and positive ions relative accuracy: ise +/-0.2 mv or 0.05%, whichever is greater range: ise 0 to 19999, resolution: ise other, nephelo turbidity meter:-systronics make, model-132, photodiode detector, range-0-1000 ntu in 4 ranges (automatic), accuracy: +/-3% of fsd in 0-1 and 0-1000 ntu, +/-2% of fsd in 0-10 and 1-100 ntu, hot plate rectangular (ce & iso certified):- material- aluminium, size: 60x45 cm, dimension: 300x450x150 mm with temperature display and mcb protection, all quartz double distillation unit- vertical (ce & iso certified):-bi double distillation water unit 1.5 lph, vertical unit types, built in quartz heater capacity: 7 kilowatt, hot air oven digital:-material:- stainless steel, chamber volume: 100 ltr, temperature range: 50-300 degree celsius, eye wash:-stainless steel emergency shower and eye washer surface mounted, online ups of rating 2.0 kva with battery, digital thermometer with probe:-temperature range: -20 to 1000 c humidity range (rh %): 100%rhhumidity accuracy: 3.5%rh, digital thermo hygrometer:-humidity range (rh %)-0-100% rhtemperature range: -20.00 - 60.00 c, n.b: the amount put to tender is exclusive of gst. the intending bidders should offer their rate which shall be exclusive of gst as per norms. gst applicable onwards contract shall be paid over the bill amount at the time of payment of each bill.
Tender For supply of chemistry lab equipment - procurement of chemistry lab equipment, uv visible spectrophotometer equipped with integrating sphereapplicable for both solid and liquid sample, powder sample kit, diffuse reflectance standards of 2%, 5%, 10%, 20%, 50%, 100%, neutral density filter to obtain linearity for transmittance, and pc control(configuration: insight software for instrument along with core i7 processor and 512gb ssd), electronic balancestainless steel weighing plate, measuring range resolution: 0.001 g, weighing capacity measuring range 120 g, parameter 0.001 g readability (1 mg), capacity 120 g, outside size 20.5 cm (8 in.) 35 cm (13.75 in.) 9 cm (3.5 in.) weighing pan diam. 115 mm (4.5 in.), ph meterrecorder output 0 to 10 mv/ph, 0 to 10 mv/100mv (adjustable), ph range 0-14 phph resolution 0. 01, ph temperature compensation 0 - 100 c, mv accuracy 1 mv, magnetic stirrercapacity 1 litre,stirring paddle q-19 9 x 25 mm,dimensions 150 x 220 x 150 mm, with hotplate, capacity 5 litres, double distillation unit1.5 lph, material borosilicate glass with double stage distillation setup, pyrogen free dimension 650 x 630 x 520mm, flame photometergeneral range ppm, serum range meq,i,urine range meq,i,resolution 0.1 ppm / 0.1 meq,curve at accuracy 2% of fsdisplay 128 x 64 graphical lcd average time in-built in software,flame system lpg & dry oil free air,detector photodiode,aspiration time 3 ml per minute,gas control adjustable with knob,flame failure auto detection,gas cut off automatic,ignition system auto ignition,automiseraxial flow type,dimensions instrument: 365 x 245 x 220 mm approx. (lxbxh),pc interface usb power supply 230 v ac 10%, 50 hz, chromatography chambersize 26x13x26 height 26inch material teak wood, potentiometerrange: 0 to 199.9 mvresolution: 0.1 mvrepeatability: 1mvaccuracy: 1 mv 1 digit input impedance :> 1010 ohms operating temperature : 10 c to 50 c display : 3.5 digit bright red seven segment led display with auto polarity indication power : 230 10% ac ,50hz dimensions : 76*275*170 mm (approx.) weight : 2 kg. (approx.) standard accessories glass electrode : 01 no. reference electrode : 01 no. silver electrode : 01 no. platinum electrode : 01 no. dust cover : 01 no. electrode stand & clamp : 01 no. instruction manual : 01 no., polarimetrytouch screen, no warmup time required when instrument turned on, measuring multiple scales, conductivity meterresolution 0.1 ppm voltage 220 v,ec resolution 0.1 temperature range 0-100 c probe conductivity cell weight 1.5 kg auto cell constant measurement manually cell constant =1k dimension 32/23/18cm display type 3 1/2 digit seven segment led display measurable conductivity range in ppm number of ranges 5 power 230-volt main type of temperature compensation manual no. of calibration points 1 temperature compensation auto cond. range 0-1000 m in 5 range 200m*,2m,20m,200m,1000m phase single phase usage laboratory frequency 50 hz power source electric, handy ph, tds, and conductivity meterph range (-) 2.00 to 16.00,ph accuracy 1%,ph resolution 0.01 ph, orp range 1000 mv,orp accuracy 1%,orp resolution 1 mv,conductivity range,0 to 100 ms/cm,conductivity accuracy 2%,conductivity resolution 1 s,tds accuracy 2%,tds resolution 1 ppm,salt range 0 to 50 ppt,salt accuracy 2%,salt resolution 1 ppm,temp range 0 to 100 deg c,temp accuracy 0.2,temp resolution 0.1 deg c,atc yes,power aaa (1.5v) x 4 batteries, printerconnectivity technology usb, networkprinting technology laser special feature automatic document feeder, fast printing, scanner, copier colour blackmodel name laserjet pro mfp m128fnprinter output monochromemax print speed monochrome 20item weight 11100 gramsprinter media size maximum a4, b5, a6, dl, envelope, ups3kva online ups with 1 year batteries warranty
Tender For corrigendum : supply of detector , vacuum system , pump , auto sampler , column oven , photodiode array detector: , control software and data analysis software: , computer and accessories ,