Get complete information related to latest Voltage Transformer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Voltage Transformer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Voltage Transformer Tenders.
Tender For supply of primary voltagetransformer (pos no. 3) 25kv/200v-50 hz-30 va, abb document no. 3ehp5 85856r0001 or latest (clw specn. no clw/es/3/0009 alt-c) clw drg. no. clw/es/3/sk-1/0009 alt-c [ war ranty period: 30 months after the date of delivery ]
Tender For sensors and measurement lab equipment - purchase of sensors & measurements laboratory, voltage, current and power measurement in single phase ac circuit digital power monitor- 10 asingle phase variac 0-240 v, 5 arheostat as load -500 , 5 avoltmeter 0-300 vammeter 0- 5 awattmeter analog 0-3000 welectrical panel & wiring , measurement of current in 3 phase circuit using single ammeter ammeter selector switch 440 v, 6 a 3 loading 5 a 3 phase variac 5 acurrent transformer 3 nos.ammeter 0-10 aelectrical panel, wiring & switches, measurement of resistance using wheatstone bridge necessary connecters provided to connect four arms range of measurement: 5 - 100k accuracy (min to max.): +0.2tolerance: +5%one digital meter provided to indicate the balance conditionsbuilt-in power supplynecessary patch chordsdecade resistance box, measurement of earth resistance by earth tester suitable connectors for 4 main arms and 2 adjacent armspotentiometer to keep the bridge in balance condition.inbuilt 1 khz oscillatormeasuring range : 25mh - 500mhsensitivity : +2mhbulit in audio amplifier with speakerbuilt-in power supplynecessary patch chords decade inductance box, measurement of inductance using anderson bridge suitable connectors for 4 main arms and 2 adjacent armspotentiometer provided to keep the bridge in balance condition.inbuilt 1 khz oscillatormeasuring range : 25mh - 500mhsensitivity : +2mhbulit in audio amplifier with speakerbuilt-in power supplynecessary patch chords decade inductance box, measurement of capacitance using schering bridge suitable connectors with 4 arms providedprovision to connect the unknown capacitance at one armtwo potentiometers provided to keep the bridge balance condition.inbuilt 1 khz oscillator and audio amplifier with speakermeasuring range: 0.001uf - 2.0ufsensitivity: +0.1uftolerance : +5%decade capacitance box , temperature measurement thermocouple trainer kit sensor type: thermocouplerange: upto 99 degree centigradetemperature source: water bath ( 1 kw)bridge: full bridge configurationsignal conditioning output: (0-5) vdcdisplay: 31/2 digital led display & analog thermometeroperating voltage: +12 vdc. -12 vdc, + 5 vdc, - 5 vdctest points: 2 mm sockets, temperature measurement rtd trainer kit sensor type: rtd (pt100)range: up to 99 degree centigradetemperature source: water bath ( 1 kw)bridge: full bridge configurationsignal conditioning : (0-5) vdcdisplay: 31/2 digital led display & analog thermometeroperating voltage: +12 vdc. -12 vdc, + 5 vdc, - 5 vdctest points: 2 mm sockets , behavior of proximity sensors proximity sensor of inductive provided to detect the metallic object. capacitive sensor provided to detect both metal and non-metal object.switching circuits provided to actuate the buzzer and relay.inbuilt regulated power supply.housed in a powder coated cabinet, linear variable differential transformer measurement trainer type: inductiverange: (0-25) mmexcitation: 4 khz, 1 v pp sine wavecalibrated range: (0-20) mm or + 10 mm/-10 mmsignal conditioner output: 0-5 vdc or +5/-5 vdcdisplay: 31/2 display digit ledmicrometer range: (0-25) mmtest points: 2 mm sockets, performance of ultrasonic and moisture sensors arduino uno board ultrasonic sensor to measure the distance.moisture sensor to measure the humiditylcd displayselector switch for display of sensor output.regulated power supplymount in a closed cabinet
Tender For corrigendum : supply of material/equipments as per the details given in the boq required for divisional stores falling under the jurisdiction of tlmd-i bemina - single phase, 50 c/s 132kv voltagetransformers (132/ 3) kv/ (110/ 3)v, one min power freq withstand 275kvrms galvanised tank. acc class 0.2, single phase, 50 c/s 36kv current transformers (20-10/1-1 a or as per site specifications), 31.5ka for one second, rated dynamic current 31.5ka (peak), class a insulation, burden 20 va, 2 no ps core, 1 no 5p20, 1 no 0.2s class, galvanised tank, including first fill of transformer oil plus 20% extra and all accessories, auxiliaries etc, single phase 50 c/s, outdoor metal oxide gapless type, 120kv (rms) surge arrestor, class 3 including surge counters/monitors, insulating base all associated accessories, auxiliaries, single phase 50 c/s, outdoor metal oxide gapless type, 30kv (rms) surge arrestor, class 3 including surge counters/monitors, insulating base all associated accessories, auxiliaries, single phase, 50 c/s 145kv current transformers (1200-800-400/1-1-1-1-1 a or as per site specifications), 40 ka for one second, rated dynamic current 100ka(peak), class a insulation, burden 20va 3no ps core, 1no 5p20, 1no 0.2s class, galvanised tank, including first fill of transformer oil plus 20% extra and all accesories, auxiliaries etc
Tender For supply of sw4960457058: voltagetransformer with plug in type inner cone size 2 (for bpt) as per annex a -ite , sg4943537014: voltagetransformer with plug in type outercone size 2 (for lpt) as per annex a -item
Tender For supply of primary voltagetransformer to clw specn. no. clw/es/3/0009 alt c & str no. clw/2021/eldo /e/str/0023 rev 1 dated march 2022. [ warranty period: 30 months after the date of delivery ]
Tender For supply of primary voltagetransformer as per clw specn. no. clw/es/3/0009/ alt- c or la test [ warranty period: 30 months after the date of delivery ]