Tender For supply of material for ac system - fire damper fire damper with auto resetting, limit switches, indication lamps etc. , fire damper motorized actuator with single phase power supply for the above fire dampervolumecontroldampers. , gss zinc coating 275 gms per m2 ducting complete with hangers supports, dampers, grilles, diffusers with and without vcd etc , variable air volume vav box complete with damper, differential pressure sensor, motorised damper, actuator, following air flow capacity 50- 990 cfm , variable air volume vav box complete with damper, differential pressure sensor, motorised damper, actuator, c air flow capacity 1000- 1990 cfm , variable air volume vav box complete with damper, differential pressure sensor, motorised damper, actuator, air flow capacity 2000 - 2990 cfm , insulation for pipe and valves - 150 mm dia, 75 mm thick , insulation for pipe and valves - 125 mm dia, 75 mm thick , insulation for pipe and valves - 100 mm dia, 75 mm thick , insulation for pipe and valves - 80 mm dia, 75 mm thick , insulation for pipe and valves - 65 mm dia, 75 mm thick , level gauges , air pressure switch , water differential pressure switch , flow meter , btu meter complete in all respect like provision of energy consumption measuring and data storing facility of energy consumption of at least 1 year with sufficient memory space. , temperature and humidity sensor , temperature and humidity indicator with sensor , occupancy sensor , co2 sensor
Tender For corrigendum : supply of supply of 7tr precision package ac units , itc of precision pac units , sitc of 15.9 mm dia. hard drawn copper refrigerant piping , sitc of 22.2 mm dia. hard drawn copper refrigerant piping , supplying and laying of 2x2.5 sqmm copper cable , supplying and laying of 4x16 sqmm aluminium cable , providing and fixing 40 mm dia cpvc pipe , providing and fixing 19 mm dia.cpvc pipe , supplying and installing of 150mmx50mmx1.6mm gi cable tray , supplying and installing of 300mmx50mmx1.6mm gi cable tray , supplying and fixing of 25mmx3mm gi strip , sitc of unit mounted motorised volumecontroldamper , providing flexible double layer canvas
Tender For tender for supply of shifting of pac units from jaisalmer to sardarpura and basni jodhpur - supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 0.63mm thick gss sheet etc complete as required. , supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 0.80mm thick gss sheet etc complete as required. , supplying , installing , balancing and commissioning of fabricated at site gss sheet metal rectangular/ round ducting complete with neoprene rubber gaskets , elbows , splitter dampers , vanes , hangers , support as per approved drawing and specifications of 1.00mm thick gss sheet etc complete as required. , sitc of gi volumecontroldamper complete with neoprene rubber gaskets , nuts , bolts , screws linkages , flanges etc. as per specifications etc complete as reqd.. , supplying & fixing of powder coated extruded aluminium return air grills with louvers but without volumecontroldampers complete as required. , sitc of 4x16 sqmm pvc insulated pvc sheathed aluminum conductor armoured cable on the existing ms tray /walls with saddles/pvc of cables with glands etc. as required , sitc of 3x2.5 sqmm pvc insulated pvc sheathed copper conductor armoured cable for control wiring on the existing ms tray / walls with saddles/pvc thread/cable tie , screws etc. i/c end termination of cables with glands etc as required. , sitc of 40mm upvc pipe for plumbing work for drainage requirement i/c reducer , elbows , tees , unions , bends , sockets , flanges etc. for making water line connection forvarious package units of system etc. complete as required. , sitc of 20mm upvc pipe for plumbing work for drainage requirement i/c reducer , elbows , tees , unions , bends , sockets , flanges etc. for making water line connection forvarious package units of system etc. complete as required. , sitc of 100mm width x 50mm x 1.6mm thickness size of perforated ms cable tray i/c fabricating i/c horizontal and vertical bends reducers tees , cross members and other accessories as reqd , and duly suspended from the ceiling with ms suspenders and including paint etc. as required. , sitc of 150mm width x 50mm x 1.6mm thickness size of perforated ms cable tray i/c fabricating , horizontal and vertical bends reducers tees , cross members and other accessories as reqd , and duly suspended from the ceiling with ms suspenders and including paint etc. as required. , sitc 25mmx5mm thick g.i. strip for loop earthing on cable tray wall etc complete as required , dismantling & removing the existing laid old power/control cables of booster fans , old package units , condenser units , heaters/pre-heaters system , humidification etc. complete by unscrewing/cutting from the related m.s. racks/tray as required , lowering down the same from different floor to ground floor & shifting the same to the place inside the exchange premises as directed by eng.-in-charge. , dismantling / removing the existing fitted old defective/working/ /worn out 05 nos.package a.c. units with related condensers & accessories like canvas connection , duct damper & place at out side ac plant room at same floor etc as directed by eng.-in-charge. , recovering the existing laid refrigerant piping of old defective/working / worn out hot gas & cold gas of different sizes complete by cutting/unscrewing /opening etc. fitted in between the package unit & condenser unit lowering down the same from different floor to ground floor and shifting the same to the place inside the exchange premises/keeping in safe custody as directed by eng.-in-charge. , dismantling the existing old ducts of pac
Tender For corrigendum : supply of filter , supply- ac and ventilation system- air intake louver , supply- ac and ventilation system- gravity damper , supply- ac and ventilation system- axial flow supply fans- 5500 cmh , supply- ac and ventilation system- axial flow exhaust fans with flp motor -7500 cmh , spares- ac and ventilation system -v-belt for ahu blower of each type , spares- ac and ventilation system -ahu blower bearings of each type , spares- ac and ventilation system -blower motor bearing for ahu , spares- ac and ventilation system -pre filter for ahu , spares- ac and ventilation system -fine filter for ahu , spares- ac and ventilation system -relative humidity sensors , spares- ac and ventilation system - geyserstat , spares-ac and ventilation system- local humidity temperature indicators , etc- ac and ventilation system- air cooled dx type condensing unit- minimum 33 tr actual capacity , etc- ac and ventilation system- air handling unit- ahu , etc- ac and ventilation system- fresh air fan assembly , etc- ac and ventilation system- split ac unit - 2 tr , etc- ac and ventilation system- strip heaters , etc- ac and ventilation system- pan humidifier , etc- ac and ventilation system- copper refrigerant piping- suction line , etc- ac and ventilation system- copper refrigerant piping-liquid line , etc- ac and ventilation system- refrigerant gas , etc- ac and ventilation system- gss duct sheet-24 g- air conditioning system , etc- ac and ventilation system- gss duct sheet-22 g- air conditioning system , etc- ac and ventilation system- gss duct sheet- 20 g- air conditioning system , etc- ac and ventilation system-gss duct sheet- 18 g- air conditioning system , etc- ac and ventilation system-non return damper , etc- ac and ventilation system-volumecontroldamper , etc- ac and ventilation system- fire damper , etc- ac and ventilation system- motorised actuator for fire damper , etc- ac and ventilation system- grills diffusers , etc- ac and ventilation system- accoustic insulation , etc- ac and ventilation system- thermal insulation , etc- ac and ventilation system- dp switch , etc- ac and ventilation system- air flow switch , etc- ac and ventilation system- temperature cum rh sensor , etc- ac and ventilation system- fine filter , etc- ac and ventilation system- air intake louver , etc- ac and ventilation system-gravity damper , etc- ac and ventilation system- axial flow etc fans- 5500 cmh , etc- ac and ventilation system- axial flow exhaust fans with flp motor -7500 cmh , etc- ac and ventilation system-cable laying and termination alonwith lugs glands and any other accessories