Get complete information related to latest Warming Blanket Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Warming Blanket Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Warming Blanket Tenders.
Tender For corrigendum : supply of consumables for construction of hybrid energy device - mild steel sheet, 8ft x 4ft x 1.2 mm, mild steel angle rod, 1.5 inch x 20 ft, mild steel angle rod, 1 inch x 20 ft, mild steel welding rod, diameter: 3.15 mm, mild steel perforated sheet, 8ft x 4ft x 1.2 mm, stainless steel 304 sheet, 8ft x 4ft x 1.2 mm, stainless steel 304 perforated sheet, 8ft x 4ft x 1.2 mm, stainless steel 304 pipe, 1.5 inch dia, 1.5 inch dia, 1.2 mm, 20 ft, zinc alloy door handle lock, stainless steel 304 welding rod, 2.5 mm diameter, ceramic fibre blanket insulation, 24"x12"x1", ceramic fibre rope, 10 mm diameter, 30 m length, heat insulating gasket, 8 ft x 4 ft, 5mm thickness, heat resistant spray paint 225 ml, silicon pipe 1/2 inch inner dia, 10 m, high temperature silicon hose pipe, 2 inch inner dia, 12 feet, worm-drive tubing clamps, chrome steel, hose clamp, 1/2 inch dia, worm-drive tubing clamps, chrome steel, hose clamp, 1 inch dia, worm-drive tubing clamps, chrome steel, hose clamp, 2 inch dia, worm-drive tubing clamps, chrome steel, hose clamp, 3 inch dia, galvanized mild steel set of nut, bolt and washer, 8 mm diameter, 2 inch length, temperature sensor with digital display, k. type, 0-1250 c, adruino uno r3 development board, rod heater, 8.2 mm diameter, 12 inch length, quartz furnace observation glass, temperature: 1200 °c, 10 cm diameter, 5 mm thickness, copper tube 1/2 inch dia, 23 swg, copper electric wire 6 sq. mm, 90 m, copper electric wire 2.5 sq. mm, 90 m, mcb dp 32 a, electric socket 16 a, electric plug 16 a, combined box 20 a, anabond gasket maker 85 g, heavy load caster swivel diameter: 100 mm, galvanized iron pipe b class diameter: 1.5 inch, length: 40 ft, galvanized iron pipe b class diameter: 1/2 inch, length: 20 ft, galvanized iron pipe b class diameter: 3/4 inch, length: 20 ft, stainless steel 304 ball valve diameter: 1.5 inch, stainless steel 304 ball valve diameter: 3/4 inch, stainless steel 304 ball valve diameter: 1/2 inch, check valve, brass diameter: 1.5 inch, check valve, brass diameter: 3/4 inch, check valve, brass diameter: 1/2 inch, metal cutter grinder disc, pack of 10, grit number 220 diameter:, 4 inch, grit material: aluminium oxide, metal cutter grinding wheel, pack of 5, grit number 4, diameter:, 4 inch, grit material: aluminium oxide, flap disc. pack of 10, grit number 80, diameter: 4 inch, grit, material: aluminium oxide, flexible heavy duty 3 layer pvc water pipe, diameter: 4 inch, length: 30 m, teflon tape for plumbing, pack of 10, 12 mm thick and 10 m length, heat resistant gloves, material: leather, size: 30.48 cm, nitrile disposable hand gloves, pack of 50 pieces, size: l, 150 microfarad capacitor, 230 v, 150 microfarad, 230 v, anti vibration rubber ribbed pads, pack of 4, 150mm x 150mm x 12mm, square pillow block bearing ucf204, 20 mm diameter, inner ball mounted pillow block insert bearing kp08, 8 mm bore, step down transformer, 220v ac to 12-0-12 v, 1.5a, single strand wire, diameter 0.51mm,5m, moc3021 moc 3021 optocoupler, bta16-600b triac, 600v, 16a, switch, sw-spst, in4007 diode, 100kv, ia, bldc motor with compatible e-bike controller, 48v 900w 3300rpm, lithium-ion battery, a grade 3.2v 2000mah (5c), battery management system, li-ion 13s 48v 20a, nickel strip, 0.2 mm thickness, 10 mm width, 5 m length, silicon wire, 12awg, insulation paper, 65mm, glue gun, 40 w, spot welding rod 5000 w, cpu fan 12 v dc, thermoelectric generator (teg), 150°c, module configuration: sp1848-27145, tungsten rhenium thermocouple, minimum temperature reading: 0°c, maximum temperature reading: between 2300°c and 2871°c, max31856 instrumentation amplifier, resolution: 0.0078125°c, supply voltage: 3.3v to 5v, arduino uno r3 with adapter cable, miniature circuit breaker fuse, d type, 32 а., power rocker switch, voltage rating: 24 vdc, current rating: 14 ma, 19mm size red power symbol led s.s. momentary type push button switch 5v-24v dc, potentiometers 100 k ohm, potentiometers 1 m ohm, relay module-
Tender For corrigendum : supply of supply of consumables /implants /devices/accessories, on consignment basis for ctvs - ventilator, invasive pressure monitoring, iv drip sets, anticoagulation monitoring and airway consumables, bain circuit adultbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., bain circuit pediatricbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., corrugated tube connectorshould allow connection between all breathing circuits and the et tube connector.thecorrugatedtubeshouldbeexpandable.shouldallowmovementofbreathingcircuitatpatientend.should be made of medical grade pvc.should be compatible with ett and tracheostomy tube., micro aggregate blood filter for red cell transfusionfilter media should be 40 micron rated polyester screen media with uniform pore sizeshould have total filter surface area of 170 sq.cmshould have average capacity of filtering 10 units of blood., packed red cell & whole blood leucocyte reduction filters.bedside filtration of one & two unit of packed red blood cells or whole bloodshould have universal spike with microbiological recovery ventshould be with attached straight administration set/automatic self leveling drip chamberperformance should consistently average less than 2x105 residual leukocytes per unitred cell recovery should average greater than 90%.filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filterit should be single use, forced warmingblanketshould be disposable and two layered; should consist of non woven propylene fabric for body warming. should be usable with forced air warming units. material should be latex free and should meet flammability standard 16 cpr 1610 for safety. the manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets full body adult underbody adult with arm and head openings pediatric full body pediatric underbody blanket. should be compatible withcommon machines. should be ce certified, cuff inflator and pressure gauge itisusedtoinflate& preciselymonitorthecuffpressureofet tube, tracheostomy tube and lma cuff. reducetheriskofpressurenecrosisandmucosal ischemia theriskofaspirationcanbeavoidedeliminatestheuseofsyringestoinflate&deflatethecuffs. should have release valve to adjust the pressure. gaugecalibratedincmh2owiththedetachablelongconnecting tube. shouldhaveinflationbulbfortheinflationofthecuffshouldhavethehookatthebackoffitsintostandardrail.should have widely spaced scale markings with colour coded pressure ranges.ergonomiconehadoperation, intubation pillow reusable intubation pillow for head elevated laryngoscopy position (help) for airway management of obese &l arge framed patients. shouldbemadeupofdensefoam. shouldbesuppliedwithheadcradle shouldbevinylcovered shouldbecemarked, negative insipratory force meter should be disposable, compact, light weight & amp;single patient use negative inspiratory force meter to check the negative inspiratory force of the ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. shouldbe ,ce marked, capnography co2 sampling mask shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth should have the facility to deliver oxygen; allow sampling of exha