Get complete information related to latest Warning Equipment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Warning Equipment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Warning Equipment Tenders.
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For maintenance of electrical installation & fans and pumps i/c compound light, substation equipment, dg set, fire fighting wet riser sprinkler system, fire alarm, pa system, lifts dumb waiter and air conditioning plant at national medical library, ansari nagar, new delhi.(sh: supply, installation, testing and commissioning of lt panel & miscellaneous fire fighting works)
Tender For annual operation and running maintenance of office building at aaykar bhavan, jamnagar. sh - operation of internal ei, fans, light fittings, substation equipment, fire fighting & sprinkler system, fire alarm system, maintenance of internal ei & fans, operation of lifts
Tender For armo of internal ei & fans, pump set, lift, substation equipment, fire fighting & sprinkler system, fire alarm system, hvac system, cctv, lan, ibms & epbax system in office building for income tax department at jamnagar for year 2024-25. sh - operation of 3 x 180 tr ac plant.
Tender For comprehensive maintenance of class room complex and venkatachala boys hostel at national sanskrit university, tirupati. sh.maintenance of iei and fans, street lights, firefighting equipment, fire alarm, split ac unitssubwork/packages:one
Tender For corrigendum : maintenance of electrical installation and fans i/c compound lighting, operation and maintenance of s/stn. equipment, d.g.set, w s and dewatering pump sets, wet riser, automatic fire alarm system and operation of lifts, operation and comprehensive maintenance of central ac plant, vrv system and stp and comprehensive maintenace of ups, multistack parking and motorized automated sliding gate at ecgc office building, andheri e mumbai 69 sh : operation and maintenance of various e m services
Tender For supply, installation and commissioning of induction heater (11/12kva) unit with roll sliding arrangement and intelligent micro controller-bas ed electronics controls for preheating of icf wheel bearings to make: precision model pih 2003 (11/12kva) or gm 12h (11/12kva) or inventum model hib- 03-rl(11 / 12kva unit). i. specification: - 1) power - 11/12kva, 2) voltage - 415/440v, 3) working frequency -50hz +/-10%, 4) residual magnetism - less tha n 2 a/cm, 5) power control -variable steps from 10% to100%, 6) temperature control - 0 to 250 deg. c minimum with microcontroller, 7) time control - 0 to 99 min ii. standard accessories: - 1) infrared cordless remote - 1no, 2) magnetic temperature probe - 1no., 3) standard horizontal yoke of size 80x80x500m m (apprrox)- 1no., 4) special equipment trolley - 1no., 5) operating manual - 2nos. 6. safety gloves - 1pair. iii. safety devices: - 1) mcp for over load protec tion, 2) thermal safety guard, 3) probe safety alarm for probe not connected for 4-6 sec, 4) yoke safety alarm for yoke not placed on vertical support for 4-6 s ec., 5) over range setting error with alarm for both time & temperature. 6) improper use of equipment error with alarm. [ warranty period: 30 months after the date of delivery ]
Tender For design, support, supply, installation and commissioning, training, warranty and annual maintenance contract of medical cyclotron with turnkey (complete scope as per the attached document in specification) - [equipment -medical cyclotron system] medical cyclotron- bunker type, unshielded with 4 numbers niobium liquid target for 18f production (self shielded), 2 numbers niobium liquid target for 68ga production (unshielded or self shielded), 1 number solid target ( for production of 64cu,89zr, 68ga) (unshielded or self shielded) along with necessary operator and personnel safety interlock system, [equipment -medical cyclotron system] 18f based synthesis modulefully automated cassette-based synthesis module with suitable dual vertical hotcell or equvivalent to handle 20 ci of f18 radioactivity (each working chamber) for routine production of 18f based radiopharmaceuticals., [equipment -medical cyclotron system] synthesis research modulegeneral purpose 18f radiofluorination module with suitable dual vertical or equvivalent hot cell, [equipment -medical cyclotron system] solid target irradiation, processing and synthesis systemsolid target processing system with electroplating+recovery of enriched target+purification) automated module for synthesis of radiopharmaceuticals of zr89,64cu, with suitable hot cell (100 mm lead thickness) [separate prices to be provided for hotcell with camera and hotcell with pb glass window for the working chambers of the hotcells], [equipment -medical cyclotron system] fully automatic dispenser (18f)fully automatic dispenser for vial dispensing with suitable hot cell to handle 20 ci of f18 radioactivity, [equipment -medical cyclotron system] dispenser for solid target-based rpone dispenser for solid target-based radio-pharmaceuticals with suitable hot cell to handle minimum of 5 ci of activity., [equipment -medical cyclotron system] 68ga based synthesis module fully automated synthesis module for radio labelling of 68ga produced from cyclotron with suitable dual vertical hot cell or equvivalent [separate prices to be provided with camera and with pb glass window for the working chambers of the hotcells], [quality control system ] hplchplc with autosampler, [quality control system] gas chromatographygas chromatography with fid and autosampler, [quality control system]tlc scanner, [quality control system] ph reader, [quality control system] mca solid state based mca, [quality control system] dose calibratordose calibrator for qc, lead shielding, [quality control system] bet systemendotoxin test system for quality control, [quality control system]bod incubator, [quality control system] l-bench l-bench for target maintainance, [quality control system] l-bench (qc)l-bench for qc of pet radioharmaceutical, [quality control system]laminar flow benches, [radiation monitoring equipment] central radiation monitoring systemsystem includes software for online data acquisition and backup for six months., [radiation monitoring equipment] gamma area monitor gamma area monitor (0-100mr/h), [radiation monitoring equipment] remote probehigh range gamma monitor with remote probe, [radiation monitoring equipment] stack monitoring systemnai detector for on line stack monitoring systemlead castle for stack monitoring probeintegrated radiation monitoring computer system with complete cabling up to the top floor of building.stack monitoring channel local alarm unitssoftware system for stack monitoringmonitor channel connection kitspare parts kit for stack monitor, stacking monitor channels, area monitors, [radiation monitoring equipment]hand & foot monitor, [radiation monitoring equipment] personal pocket dosimeters (digital), [radiation monitoring equipment] portable gamma dose rateportable gamma dose rate meter + contamination probe, [radiation monitoring equipment] portable survey monitor for neutron, [radiation monitoring equipment] remote probe survey neutron monitor (high range), [radiation monitoring equipment] por