Web Analytics Made Easy - StatCounter

Water Absorption Testing Tenders

Get complete information related to latest Water Absorption Testing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Absorption Testing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Absorption Testing Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :43771362 Due date: 05 Feb, 202605 Feb, 2026 NA
Tender For supply and installation of electrical and mechanical equipment of tubewell at road no.66 jafrabafad and shastri park tubewell. (re-invite) - supply and installation of electrical and mechanical equipment of tubewell at road no.66 jafrabafad & shastri park tubewell by carrying out following works:- dismantling/lifting of tubewells with the help of gas cutter and heavy manual labour., supply of pvc insulated sheathed copper conductor cable for submersible pump motor of size 6mmsqx3core make :- finolex/ havells/ grandlay/djb approved make, supply of 80 mm dia d/f g.i pipe in b class as per isi 3 mtr long complete with cutting flange for submersible cable and support welded. make :- jindal/ tata., supply of tail piece medium class 0.5 mtr long including one end flanged and other end threaded of 80 mm dia., supply of 80 mm dia g.i bend with both side flanged welded, s/o m.s. clamp of m.s. strip 8mm thick duly hole for holding the pipe of 80 mm dia with nut bolt and washer, s/o m.s bore cover made out of m.s. plate suitable for 12" dia bore complete with suitable hole for pssing the 80mm dia gi pipe., s/o ci, d/f swing type nrv of 80mm dia make:- kirloskar/ ivc/djb approved make., s/o electronic dozing pump (4lph,5.5 kg) electrically controlled operated 230v, 50 hz, supply chemical grade tank of 100 ltrs with pipe make- milton roy/clomax, s/o nut bolts with washer of good quality of 1/2"x2" size, s/o rubber packing sheet synthetic 50% make :- jyoti / national, lighting arrangement including providing fixing1 no. tube light fitting 40 watt, 1 no. bulb point, 1 no. flood light on wall of room and also control board.etc.i/c electrification of room., labour charges for lowering the submersible pump set with all allied e&m equipments and fixing delivery line, valves, electronic dozing pump i/c hardware items as nut, bolts & washer i/c cartage to & fro., lt panel work of tubewell in road no.66 jafrabafad & shastri park tubewell:- dismantling of lt panel with allied equipment with the help of skilled labour., s/o power contactor 32 a. triple pole. make l &t/ havells, s/o front mounting add on aux contact block. make : havells/l&t, s/o three pole power contractor -25a cap. make l&t/ havells, s/o ampare meter (0-30a) 4 size squ. type. make l&t/ae, s/o voltmeter (0-500v) 4 size squ. type. make ae/l&t, s/o indicating lamp set for ryb phase. make l &t/ havells, s/o single phase preventor. make l&t/ minilac, s/o timer switch digital/anolog type. make l&t / havells, s/o over load relay thermal type 14-23 a. make l &t/ havells, s/o star delta timer on delay. make l&t /havells, s/o sp mcb 6a. make : l&t/havells, s/o 3p mcb 63. make : l&t/havells, push button 22.5mm(red / green), s/o 4p 63 amp elcb make : l&t/havells, changeover switch 63 amp., s/o 100a 3p mccb 25ka. with spreader make : havells/l&t., s/o rubber mat for electrical purpose of size 1mx2m and 3mm thick. make:- jyoti/ national, labour charges for repairing of lt panel with installation of above components i/c electric connection , testing and commissioning on load.

Central Government / Public Sector

CTN :43554283 Due date: 10 Feb, 202610 Feb, 2026 NA
Tender For corrigendum : supply, installation, testing and commissioning of mechanical equipment for 4 tph capacity biomass based pellet production plant at karnal, haryana

State Government

CTN :43497502 Due date: 10 Feb, 202610 Feb, 2026 1.50 Crore
Tender For corrigendum : supply, installation, testing and commissioning of laboratory equipment ellipsometer at institute of science, banaras hindu university

State Government

CTN :43428357 Due date: 07 Feb, 202607 Feb, 2026 60.90 Lacs
Tender For corrigendum : renewal of nabl accreditation of 22 water quality labs reg. consultancy and services for testing and calibration of laboratory equipment and obtaining isoie 170252017 nabl accreditation for water testing laboratories under jal jeevan mission

State Government

CTN :43703906 Due date: 06 Feb, 202606 Feb, 2026 3.52 Lacs
Tender For corrigendum : services for testing and calibration of laboratory equipment of 11 nabl accredited water testing laboratories in 10 districts of jammu province under nwqmsp (jjm) for year 2025-26

State Government

CTN :43754834 Due date: 05 Feb, 202605 Feb, 2026 14.10 Lacs
Tender For supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - supplying installation testing and commissioning of laundry equipment in ashadeep narela delhi - sitc of front loading washing machine with loading capacity of 30 kg dry weight per charge heavy duty , electrically heater inner basket & outer drum stainless steel, micro countroller base cyclic timer for auto- reserve, auto- timer & auto digital temperature control, water- inlet valve drain valve complete with control panel, & electric motor for wash, driver through pulleys & v- belts and control panel operator on 3ph, 415 v, 50 hz, a.c. supply operation cycle 30 to 40 mintutes complete connection etc as required, sitc of hydro extractor machine direct- driver self- balance with automatic electromangnetic dc injection brake system having capaciy of 30 kg per charge with auto -timed top loading vibration less innner basket and outer drum stainless steel complete with specially designed electric motor and control panel operator on 415 v,3 phase , 50 hz ac supply . operation cycle 5 to 10 mintes complete connection etc as required., sitc of drying tumbler machine front loading open pocket, electrically heater with loading capacity of 30 kg . per charge complete with micro controller base cyclic timer for auto timed & auto - reserver, auto digital temperature control, fitted with control panel , one motor each for driver and blower double walled glass wool insulated outer body mild steel with inner basket stainless steel, self lint screen , v belt driver waster air exhaust etc operates on 415 v, phase 50 hz ac supply . operation cycle 40 to 60 mintes complete connection etc as reqd, supplying and drawing following sizes of frls/hffr pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.a) 3 x 4 sq. mm, b) 6 x 4 sq. mm, supplying and fixing of following capacity, 240/415 volts, 10ka/15ka c series mcbs suitable for lighting and other loads of following poles in the existing mcb db complete with connection, testing and commissioning etc as reqd.a) 40a, 10 ka , fp mcb (415v), b) 63a, 10 ka , fp mcb (415v), supplying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size complete as required.a) 4x 16 sqmm, b) 4x 25 sqmm, supplying, installation, testing & commissioning of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85%, operating voltage ac 140- 270 volt, frequency 50/60 hz, operating temp range -5 c to 40 c, internal surge protection of 2.5 kv with short & open circuit protection, thd 10%, p. f. 0.95, ip20, cri >80, flicker free, (flicker shouldbe below 5 %), life time (led, driver & electrical circuitry), of minimum 50000 burning hours with 70% of initial lumen maintained till life ends, cct 3000 k / 4000 k / 5700 k /6500 k (as per ansi bin), sdcm(standard deviation colour matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard. manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm frls/hffr, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80 test report and all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminium housing such that led junction temperature shall not rise above 90 c). powder coated die cast /extruded aluminium body (thickness > 1.20 mm)a) 40 watt, laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in th

Central Government/Public Sector

CTN :43775956 Due date: 14 Feb, 202614 Feb, 2026 NA
Tender For supply of transformers, fittings & accessories for power transformers, insulating oils for transformers and switchgear, bushing for alternating voltages above1000 volts, current transformers, three phase induction motors, gas operated relays, code of practice for selection installation & maintenance of transformers, degree of protection provided by enclosure for rotating electrical machinery, specification for low voltage switchgear& control gear part-i, colors for ready mix paints, code of practice for maintenance & supervision of mineral insulating oil in equipment, industrial cooling fans, guide for loading of oil immersed transformers, specification for dimensions of porcelain bushing, tap changers, high voltage test technique, insulation co-ordination, nema standard publication for power transformers, code of practice for selection, installation operation & maintenance of pumps for industrial applications, guide for sampling & analysis of free & dissolved gas & oil from oil filled electrical equipment, porcelain post insulators for systems with nominal voltage greater than 1000 volts, specification for electric power connectors, hollow insulators for use in electrical equipment, methods for testing uniformity of coating of zinc coated articles, dimensions for oip insulated condenser bushings

State Government

CTN :43789486 Due date: 16 Feb, 202616 Feb, 2026 33.14 Lacs
Tender For replacement of age old 66kv pneumatic circuit breaker and c&r panel of 66kv capacitor bank at 220kv r/s hoody. pertaining to tr (op) circle-south, bengaluru on total turnkey basis including supply of all matching materials/equipment including supply of 66kv breakers and erection (including civil works) of all materials/ equipment, testing and commissioning- on percentage basis

State Government

CTN :43736670 Due date: 17 Feb, 202617 Feb, 2026 NA
Tender For enquiry for refilling & changing parts of firefighting equipment at 220 kv s/s kotar, under testing dn. satna .

State Government

CTN :43714456 Due date: 13 Feb, 202613 Feb, 2026 NA
Tender For enquiry for refilling & changing parts of firefighting equipment at 220 kv s/s satna and 132 kv s/s majhgawan, nagod, under testing dn. satna.
 Loading, Please wait...

Connect us via What's Up