Tender For corrigendum : tender for supply of upper pole assembly complete with all internal parts including vaccum interrupter part no j71715199 , lower pole assembly complete with all internal parts including insulating studs and terminal part no j71715099 , vacuum interrupter part no 3vc200014 , spring charge motor part no 3vc400010 07 , closing coil assembly part no 4vc49110 , tripping coil assembly part no j4vc590189 , rectifier unit part no j9574194 , local remote switch 2 pole 2 part no j9574182 , breaker control swith 1 pole trip neutral close part no j9574183 , contact multiplication relay for 110dc antipumping part no j9574187 , winding temperature relay part no j479751 , master trip relay part no j479744 , heavy duty power pack 3 phase part no j479749 , facia enunciator 8 window part no j572656 , alarm bell hooter part no j309777 , power factor meter part no j479650 , self supervising numerical idmt relay highly sensitive for 3 o c and 1 e f broken conductor negative fase sequence protections suitable for cummunication and binary io configuration part no j573694 , bucholze alarm trip part no j480618 , oil temperature relay part no j479477 , trip neutral close switch part no j479677 , indicating lamp fitting set consist of 08 pcs part no j310092c , antipumpimg relay part no j479653 , ammeter selector switch part no j309025 , voltmeter selector switch part no j309024 , timer aux supply 220 v dc part no j9574215 , mechanism complete with spring charge motor 110v 220v dc part no j95736072
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens
Tender For supply of electrical testing equipments for pvunl - resistance tester,10kv,240vac , clamp earth tester,digital,0.01 ohm , insulation tester,500- 1000v,0.5-1kv , digital multimeter,1000vac ordc,0-10a , ac clamp meter,0-20a , ac ordc clamp meter, 1000 a ac ordc , ac voltage detector,remote sensing , leakage clamp meter , rccb orelcb tester,80-450v,10- 500ma,plus or-10 percent , analog indicator,phase sequence,96x96mm