Web Analytics Made Easy - StatCounter

Water Pump Motor Tenders

Get complete information related to latest Water Pump Motor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Water Pump Motor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Water Pump Motor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :38923768 Due date: 22 Jan, 202522 Jan, 2025 NA
Tender For supply of isolator 400amps 3.3kv reversing , vacuum contactor 400 amps 3.3kv , bridge rectifier unit complete , vaccum contactor closing coil 110v dc , vaccum contactor holding coil 110v dc , auxiliary switch for vaccum contractor 2 , p.t. 40va 0 8 12v 0 110v , auxiliary contactor 3no and 1nc 110v ac , resin cast p.t 750va 3.3kv 110v single , resin cast p.t 300va 3.3kv 110v 3 phase , ht control fuse 3.3 kv. 2 amps , resin cast moulded cbct , resin cast moulded ct for o l relay 100 , resin cast moulded ct for ammeter 150 5 , e.l.unit complete without transformer , o l rly thrml4 7.5act oprtdw mntng , ct oprted ct sec 5a motor prtectn relay , 72sq mm ammeter 0 150 450a , 72sq mm voltmeter 0 5kv , ammeter selector switch , hrc fuse base and carrier for control , hrc fuse link 4a for control , push button with element for start sto , lamp holder with lamp on off trip , power hrc fuse , single phase preventer cup 20 pfr make , copper bus bar 400 amps set of 3 , undervoltage relay , pilot realy 12dc , voltmeter selector wsitch , contactor tp.12 amps ac3 duty fitted wit

CTN :38957188 Due date: 04 Feb, 202504 Feb, 2025 NA
Tender For supply of parts - x2 nd misc 504026 temp gauge , x3 ixc kr 10 027 21 0 delivery value fii , x3 ixc al 6 65 1 f3530511 bolt 5 16 bsf for starter ring , x3 nd 2990 000513 ring starter engine for gear motor start , x3 nk 30kva 000123 full packing set , x3 nd ixc rh b 63506 seal , x2 ixc rh 4da 49024a fan belt a 57 , x3 misc 1509 10 exhaust packing , x3 nd 5330 01089 gasket rubber 110mm , x2 misc 2400 382 618 32 mcb 10a , x2 misc 2400 382 619 29 mcb 16a

CTN :38957266 Due date: 04 Feb, 202504 Feb, 2025 NA
Tender For supply of convoy lamp , caliper assy disc brake , motor assy starting , speedometer assy , generator assy , ram hydraulic ram assy , fuse 8din 72581 , armature , fuse 10 amp , jump start cable , pin cotter split steel 8 x 90 , magnetic switch , drive shaft , clutch assy fan , muffler , sensor assy cam position , assy spare wheel lifting unit , fan clutch assy , screw driver 200mm

CTN :38964536 Due date: 27 Jan, 202527 Jan, 2025 6.8 Thousand
Tender For providing of repair and overhauling service - repair of water pump motor of cooling tower-01

State Government

CTN :38974535 Due date: 25 Jan, 202525 Jan, 2025 6.00 Lacs
Tender For routine and type tests requirements based on reference standard is 2993 part 2 2024 for mpp motor start capacitors

CTN :38593714 Due date: 27 Jan, 202527 Jan, 2025 NA
Tender For corrigendum : procurement of 6.6kv rated conveying blower motor (500kw) and hp water pump motor (380kw) for stage-i under ahp-em department at bktps

Central Government/Public Sector

CTN :38587466 Due date: 20 Jan, 202520 Jan, 2025 19.66 Lacs
Tender For corrigendum : repair, maintenance, and installation of plant/ systems/equipments (version 2) - 285 instrument erection contract for revamping of flow lab at instrument workshop at rcf trombay unit; as per sow; as per sow- 1 fabrication, erection & installation of cable tray 50 mm width with necessary support m s angle 50 mm. this job includes two coat of primer and two coat of anticorrasiveepoxy coats. supply of primer and paint to be included and fabrication, erection and installation of cable tray. 50 mtr, 2 supply and installation side mounted glass tube level indicator approx 2.5 mtr length with high and low level switch adjustable over the full length. 1 no, 3 supply and installation and commissioning of centrifugal pump flow capacity of 30 m3/hr head 45 meter suitable for vfd drive 1 no, 4 magnetic flow meter 0 to 50 m3 /hr, 4" size flanged 150# rf, accuracy 0.1% with calibration certificate 1 no, 5 4" size ss material, 150#, flanged on/off valves with actuator, limit switch indication dome, solenoid valve 4 no, 6 vfd with panel and start /stop pb, and speed control 1 no, 7 pressure gauges 1 no, 8 supply, installation of piping suitable for the flow skid in sizes 4" and as per requirement 1 lot, 9 flow totalizer with contacts and set rest function 1 no, 10 panel for skid operation with pb, lamps, selector switch 1 no, 11 supply, installation of pvc coated cu tubing with necessary fittings for 4 valves 80 mtr, 12 supply, installation of air distribution header 6 points stainless steel 1 no, 13 supply, installation of 50 mm wide x 30 mm x 2 mm thick gi cable tray 100 mtr., 14 supply, installation of 100 mm wide x 30 mm x 2 mm thick gi cable tray 100 mtr., 15 supply, installation of layingof signal and power cables 300 mtr., 16 1 pair x 1.5 mm2 signal cable 300 mtr., 17 power cable for motor existing cable to be reused as per requirement 500 mtr, 18 spool pieces with one end flanged connection and other end with triclover coupling in ss304 of various sizes as below with 10d and 5d lengths. set of spool pieces shall iclude following sizes: 6", 4", 3", 2.5", 2", 1.5", 1", 3/4", 1/2" each in quantity 2 numbers 1 lot removal jobs 1 structural steel which includes ms ladder tray, stantion, alluminium cable trays 300 kg, 2 cable- signal , power cable removal 100 mtr., 3 level indicator 2 no, 4 existing piping and fittings 1 lot, 5 removal of existing pipe and fittings 1 lot

CTN :38875386 Due date: 18 Jan, 202518 Jan, 2025 6.83 Lacs
Tender For (1) repairing and reconditioning of 260hp, 550v start delta starter o motor. (2) repairing and reconditioning of 02 nos 3.3kv ocb, 400amp. (3) repairing and rewinding of 135 hp, 550volt, 1470 rpm induction motor at gidi-a project under annual repairgada annual repair

Central Government/Public Sector

CTN :38601860 Due date: 21 Jan, 202521 Jan, 2025 NA
Tender For corrigendum : supply of 132kw inverter rated sqim for cooling tower fan in cwp-5 , sqim 37kw 4p for cwp-4 , 18.5 kw sqim 4p fac aop motor , 37kw sqim 2p chilled water pump motor in asus of asp-1

Central Government/Public Sector

CTN :38157116 Due date: 17 Jan, 202517 Jan, 2025 1.30 Crore
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
 Loading, Please wait...

Connect us via What's Up