Get complete information related to latest Waveform Generator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Waveform Generator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Waveform Generator Tenders.
Tender For providing, installing, testing and commissioning of dwlr/digital groundwater level recorder- piezometer with telemetry at giridih ocp and kabribad ocp under giridih area, ccl
Tender For supply of glycel herbicide gilphosate 41 percentage si , light weight alloy spanner double end size 36mm x 41mm , mechanical track jack 15 ton capacity non infringing type , weld trimmer machine , rake ballast , rail profile gauge cum recorder detailed description as per item 6 of the attached specification document , rail profile gauge cum recorder detailed description as per item 7 of the attached specification document , rail profile gauge cum recorder detailed description as per item 8 of the attached specification document , digital gauge cum level as per rdso specification no tm-58 third revision of 2023 for pwi hill lmg , digital gauge cum level as per rdso specification no tm-58 third revision of 2023 for pwi hill nhgj , digital gauge cum level as per rdso specification no tm-58 third revision of 2023 for pwi hill nhlg
Tender For supply and installation of physics instruments - c.r.o. dual trace 40 mhz: 1. type of input channels- analog and digital (mixed signal)2. number of analog channels-3. bandwidth - 300 megahertz.4. display type -colour tft.5. minimum display size- 10 inch.6. time base accuracy- 2.5 parts per million.7. sampling rate per digital channel simultaneously: 1gs/sec.8.record length per digital channel simultaneously- 8m point., function generator 0.3 to 3 mhz (scientific 10 mhz to 25 mhz frequency 1 channel function generator) : 1. frequency bandwidth (sine wave ) 10 mhz to 25 mhz.2. sample rate of arbitrary waveformgenerator (mega samples/sec)3. amplitude range (at 50 ohm impedance),10mv to 10 v pp. , multiplexers and de-multiplexer with built in power supply :1. material- abs2. display- digital, verification of de-morgen s theorem with built in power supply : 1. type- digital2. consisting of built in power supply3. logic ics connected internally for 1st & 2nd theorem.4. 2 logic input switches with indcators.5. 1 logic output indicator.6. 3 patch chords to connect input and outputs., encoder and decoder circuit with built in power supply : 1. material- pvc2. equipment materials - glass epoxy front panel with pvc3. temperature range- -5 to 45 celsius4. output voltage(regulated) : 5vdc (internally connected) , half adder, full adder, half subtractor, full subtractor with built in power supply: 1. built-in power supply dc +5 v at 500 ma.2. 3 logic input switches with green led display.3. 3 logic output red led display.4. two and gates ( 7408 ), one or gate ( 7432 )two not gates ( 7404 ) & two ex-or gates ( 7486 ) on panel., hall probe method for measurement of resistivity, complete with hall effect setup, hall probes, digital gauss meter, electromagnet and constant current supply. (complete apparatus) : 1. hall probe (ge crystal);(b)hall probe (inas).2. hall effect set-up (digital), dhe-213. electromagnet,emu-75oremu-50v.4. constant current power supply, dps-175 or dps-50.5. digital gaussmeter, dgm-102.6. range- 0-20 ma, apparatus to study characteristics of tunnel diode : 1. instrument comprises of dc regulated power supply of 0-600mv.1. two round meter for voltage & current measurement.2. circuit diagram is printing on front panel & important connections brought out on front panel.3. with well illustrated instruction manual, photo diode characteristic apparatus : 1. material- ms2. frequency- 50hz, photo transistor characteristic apparatus : 1. instrument type- analog2. input voltage - 220 v3. frequency - 50-60 hz, solar cell characteristic apparatus (complete apparatus) : 1. analog voltmeter: 12. analog ammeter: 13. solar panel/photovoltaic cell/solar cell to study characteristics: 14. range of dc voltmeter (in volt): 305. range of dc ammeter (in milli ampere): 506. necessary patch cords for interconnection7. along with instruction manual and demonstration, apparatus to study charging and discharging of a capacitor : 1. built in power supply : +12v variable & -12v, variable dc2. mains : 230v ac , ldr characteristics apparatus. : 1. voltage- 220 v2. apparatus type- analog3. temperature range- 50-60degree, plancks constant using solar cell : 1. instrument type- digital 2. built in power supply : +12v variable & -12v3. necessary patch cords for interconnection
Tender For corrigendum : design, supply, installation, commissioning, training of various type of equipments for esdm (electronic system design and manufacturing) of msme training centers located at greater noida, bengaluru, puducherry and idemi mumbai on turnkey basis - decade resistance box , ct/pt calibration system , multifunction calibrator , decade capacitance box , ct analyzer , standard resistors , standard weights (el class) , pippete calibration system , low temperature bath (-80 to ambient degree temperature) , frequency counter , energy meter test system (3 position) , precision temperature stabilised resistance standard (high) , decade inductor box , precision temperature stabilised resistance standard (low) , sound level calibrator , digital power analyser , decade resistance box (4 nos.) , process calibrator , hv divider , decade mega ohm box , standard weights (e2 class) , 6 and half dmm , temperature indicator , time interval meter , temperature indicator with compensation , standard weights (f1 class) , semi-micro balance (upto 200 gms) , tachometer calibrator , standard thermocouple (type s) without compensation , sound level analyzer , standard platinum resistance temperature (prt) detector , precision balance (upto 6.1 kg) , thermo-couple calibartion furnace (300 to 1100 degree temperature) , lcr bridge , humidity measurement probe , dry block calibrator (ambient to 600 degree temperature) , anechoic chamber with radiated susceptbility and radiated emission test system , alltitude test chamber , compact emc tester , environmental chamber , digital pressure controller (dead weight pressure tester) , line impedance stablizing network , harmonics/flicker measurement test system , impulse generator , rf shielded chamber , vibration plus environmental chamber , three phase regulated variable power source , humidity generator, relative humidity , bump/shock test system , heat deflection temperature test set , vibration test system , electronic load , conducted rf immunity simulator , rohs testing lab - inductively coupled plasma optical emission spectrometer (icp-oes) , thermal shock chamber , ac dc current source , ultra precision capacitance bridge , esd simulator , horizontaland verticlal flame chamber , rohs testing lab - energy dispersive x-ray fluorescence spectrometer (edxrf) , single phase regulated variable power source , precision energy standard , rohs testing lab - gas chromatograph mass spectrometer (gc-ms) , ingress of water test system - i set , rohs testing lab - ion- chromatograph (ic) , needle flametest chamber , salt spray chamber , dust chamber , digital storage oscilloscope , defibrillator proof test set , thermostat endurance test set , flexing test apparatus , electrical safety tester , winding resistance meter , temperature recorder , radiation meter , tracking test apparatus , gas detector , cord anchorage test set , digital multimeter (handheld/desktop) , glow wire test apparatus
Tender For custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if required., oil le