Get complete information related to latest Wax Dispenser Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wax Dispenser Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wax Dispenser Tenders.
Tender For supply of sitc of partiulcate matter analyser , sitc of sulphur dioxide analyser and ambient oxides of nitrogen analyser , supply and fixing of multi gas calibrator and gas sampling system , supply of calibration gas cylinders , supply and fixing of oled tv with mini pc , supply of copper conductor armoured power cable , laying of pvc sheathed cable , supply and laying of hdpe pipe , sitc of junction box , supply and end termination of pvc sheathed or xlpe aluminium conductor cable , sitc of software and licenses for live dashboard and historical data in pc , providing online pcb connectivitity , sitc of software , sitc of min 4 channel data logger , sitc of data converter , laying and fixing of pvc sheathed or xlpe power cable , earthing with gi earth pipe , sitc of digital rh temperature pm 2.5 pm 10 monitoring analyser with remote transmitter and receiver , sitc of pc and necessary accessories, panel, 1 kva ups , sitc of ocems for 250 kld stp , supply of single mode 6 core armoured ofc , supplying and drawing of utp 4 pair cat 6 lan cable
Tender For supply of diffusion pump oil hivac , high alumina hearth support insulator , moly grooved strip heater , high alumina female insulator for heater support , high alumina male insulator for heater support , moly washer , copper feedthrough insulators , nylon spacer , nylon insulator , moly connecting rod for copper feedthrough , molybdenum heater connecting square block , molybdenum heater connecting holding block , copper feedthrough for feed through assembly , 8mm viton o ring , 10 hp kdi water circulation pump , 7 point 5 hp kdi water circulation pump , programming temperature controller , pressure transmitter , water pressure switch type ip 100 , 1 by 2 inch non return valve for gas manifold , 1 by 2 inch ball valve for gas manifold , complete set of viton o rings except for vacuum pumps , 1 inch carbon free hose pipe-10 mtr long , 3 by 4 inch carbon free hose pipe-10 mtr long , qsv-1 inch manually operated butterfly valve ss with both side kf 25 clamp and viton o ring , gas manifold 2 stage gas regulators , final line regulator flr , kf fittings and accessories , hhv make right angle valve model rpv-25 , rigid r type thermocouple , molybdenum plate , digital panel voltmeter 12 24 v dc , digital panel ammeter dc 10amps 20amps , on - off switch , 1 by 4 inch speed control mufflers , rotary pump oil md 504 , pneumatics pipelines with accessories , water pipe lines withaccessories , heat exchanger fixing , r type flexible thermocouple 0 point 5 dia 1.5 mtrs long
Tender For purchase of sports exercise physiology lap equipments - cardiopulmonary exercise testing system system should be compact can be used in laboratory operation and low maintenance costs and easy servicing. system should be state of the art computerized telemetry breath test analyzer for on-line breath by breath measurement of exercise test of respiratory system to measure following parameter: time, ve, bf(rr), hr, feo2, feco2, peo2, peco2, vo2, vco2, ve/vco2(eqco2), ve/vo2(eqo2), rq(rer), vd/vt, vo2/kg, vo2/kg/hr, met, watt(work), hr, ttot, ti, te, ti/te, ti/ttot, pef, pif, br, vet, sum, tv/te, o2 kinetics, oxygen deficit, oxygen debt parameters and indirect calorimetric. wireless hr recording system, indirect cardiac output by wassermann algorithm system should comply ats and ers guide line and it should be ce certified., iso certified system should have automatic ambient conditions measuring system. system should work under temperature range 0 to 50 celsius. system should have facility for automatic calibration of analyzers. volume transducer calibration with precision calibration syringe. system should meet following technical specification flow rate measurement: measuring headpiece should be either through turbine /dvt/ pneumotach and dead space less then 40 ml, it should not be affected by humidity , flow range +/- 18 l/s and accuracy 2% oxygen analyser : should be either electrochemicalcell/paramagnetic and measurement range 0- 100 %,response time t90 100 ms and accuracy +/-0,04 % and- resolution 0,02 %carbon dioxide analyser : should be ndir (infraredabsorption) and measurement range 0 - 10 %,-response time t90 90 ms , accuracy +/- 0,04 %, andresolution 0,02 % software should support latest windows or latest andin corporate customized predicted normal equations.software should be capable of changing graphics displays during real time testing. system should have facility for automatic treadmill or bicycle ergo meter control. should be supplied with software, standard accessories for operation manual carrying case for field use. system should be supplied with latest data acquisition system, deskjet printer and ups. system should comply en iso 13485:2003, en iso 9001:2000, ec certificate93/42/eec, programmable treadmill running machine with user terminal (display &keyboard) stand- alone and remote control via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 200 kg (440 lbs) speed range: 0-40 km/h elevation: 25% (14 maximum elevation) motorized adjustment, reverse belt rotation. motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v- belt, very quiet operation safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10to +40 degrees c, humidity 30 to 70% display (resolution): lcd display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs safety harness-1. indispensable accessory for stress testing, accident prevention and for the general safety of athletes.2. safety arch with different heights and widths to fit all running machines.3. an emergency stop at the crossbar of the safety arch allows automatic stop of the running belt in the moment a fall occurs.4. the harness and chest belt (available in 5 sizes: xxs, s, m, l, xl) secure the subject and prevents falling over to the front.5. chest belt straps do not pinch or restrict the athlete", programmable ergometer functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat a