Get complete information related to latest Wind Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wind Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wind Pump Tenders.
Tender For work of 1100 vm jyoti make cooling water pump & discharge valve overhauling in 375 mw ccpp-iii at dgbps. (as & when require basis) (rfq no. 70392)
Tender For corrigendum : cleaning of drains and sweeping of roads, paths, cleaning of trash racks at cw pump house and cooling towers, cleaning of stairs, railings etc. and work of 24x7 water supply in plant and non-plant buildings
Tender For tender for supply of lfh cable uniflex single core 1 sq.mm , teflon cable flu-tef single core 1 sq.mm , push button teknic 22.5 dia black(for reset) , cable gland size 6 , vibration eliminator for suction line , o ring star locating pin , main rotor , control transformer pri 0 to 415 v ac sec 0 to 230v ac 8a , vibration eliminator for liquid injection line , control transformer tape wound 415 v/110 v 150 va , set capacity regulator 24 v dc , set shut-off valve nw32 part no 08082 , setcrank shaft part no. 08056 , valve globe type 7/8inch ods , kit for power contactor for compressor stater , hrc fuse link ge ns4 4a with nh type fuse base , thermostatic exp. valve gfe-1.1/2jc charge 1/4inch x 1/2inch flare , hooter ems 0001016 24 v dc , set connecting rod part no. 08307 , set of bearing for 7.5 kw motor for 2x2.1 tr ref plant , vibration eliminator 1-3/8inch ods , evaporator pressure regulator sporlan ori(t)10 , aux contactor ge rl4 rd022td 2 no + 2nc coil -24v dc , mpcb ge 0 1.6a with 1no + 1nc contacts , valve angle type 1/4inch ntp(m) x 1/4inch flare , valve globe type 7/8inch ods , cooling fan , vibration eliminator 1-1/8inch ods , kit for power contactor for acu fan stater , power contactor ge 0 32a 415 v ac 3 pole , set oilsump heat 80w 220-240v part no.08425 , pres transmitter danfoss mbs 3100-2211-1ac04 range 0-16 bar , set of v belts , valve plate assembly part no 08436 , kit for power contactor for sw pump stater , vibration eliminator 7/8inch ods , thermostatic exp. valve gfe-1/2jc charge 1/4inch x 1/2inch flare , mcb ge 0 32a , valve globe type 1/2inch ods , valve three way type 1/4inch npt(m) x 1/4inch flare , set oil pump part no. 08044 , set of gaskets for condenser for 2 x 2.1 tr ref plant , vibration eliminator 5/8inch ods , set of bearing for 1.5 kw motor for 2x2.1 tr ref plant , set gaskets part no. 08072 , pres transmitter danfoss mbs 3100-2411-1ac04 range 0 -25 bar , temp transmitter mbt 5560-0000-0200-10-415 range - 50-150 c , set shaft seal part no. 08008 , coil for power contactor for compressor stater , safety valve 1/2inch npt(m) set pressure 12.5 kg/cm2 r134a , valve angle type 1/2inch ntp(m) x 1/2inch flare , bridge rectifer ems 0011132 25a , set piston dia 70 part no. 08035 , coil for power contactor for sw pump stater , coil for power contactor for acu fan stater , valve hand shut off type 1/4inch flare , set of push buttons (one of each type) for lcp , sea water pressure differential switch , ss needle valves 1/4inch , non return valve 3.5/8inch , fuses 1 amp 400v , compressor gauge , set of gasket ac-470 compr , gasket , crank shaft , lp-op cutout mp55r(r12-r22) , bolt hex head , three way valve 1/4inch , thermostatic expansion valve , oil filter , screw driver 10inch , pipewrench 10inch , temperature transducer , pressure transducer , ring end spanner set , angle valve 1/2inch , safety relief valve for condensor , compressore discharge pressure gauge , brg ball deep groove 55x90x18 , pump trailing (pompe pollard) type 100 pr.60.100 c.g.n. , element complete with o ring , hub clutch , spacer , gear output , key , key parallel , hose 1 1/4 bsp(f) , lock nut m 120x2 km24 , bearing spherical roller(skf24124/cc/w33) , pump assembly , gasket , o ring , temp switch , gasket , rubber bonded washer , washer plain steel , assly. union screw socket , main pump , gasket , ring piston outer , seal kit for filter assly , pressure switch xml a 0037 , heat exchanger , p.r.v , press gauge(lub) , gasket , plate lock , washer plain steel , o-ring viton 42.5x36.5x3xc , flexible gas charging line , steel foot rule 12inch , flaring tool kit , connector 1 8inch mpt x1/4inch sae , charging adopter 3 4inch fpt x 1 4inchsae , copper tube 1 4inchx 2mtr , connectors 1 4inch mpt x 1 4inch sae , indication lamp amber , set of push buttons (one of each type) for lcp , set of indication lamps (one of each type) for lcp , semi conductor fuses ge / feraaz 200a , 6.611 rd30-xx0315 , mc mccb ge 100a s 400a , with aux contact 2no+2nc
Tender For supply of various pumps for bangladesh dredger project yard 2121 - g1_1_general service pump with accessories , g1_2_on board spares for general service pump , g1_3_documentation for general service pump , g1_4_tools for general service pump , g1_5_instl - comm spares for gen service pump , g1_6_training for general service pump , g1_7_service of engineers , g1_8_warranty extension charge for 1st year , g1_9_warranty extension charge for 2nd year , g2_10_oily bilge pump with accessories , g2_11_on board spares for oily bilge pump , g2_12_documentation for oily bilge pump , g2_13_tools for oily bilge pump , g2_14_instl - comm spares for oily bilge pump , g2_15_training for oily bilge pump , g2_16_service of engineers , g2_17_warranty extension charge for 1st year , g2_18_warranty extension charge for 2nd year , g3_19_fuel oil transfer pump with accessories , g3_20_on board spares for fo transfer pump , g3_21_documentation for fuel oil transfer pump , g3_22_tools for fuel oil transfer pump , g3_23_instl - comm spares for fo transfer pump , g3_24_training for fuel oil transfer pump , g3_25_service of engineers , g3_26_warranty extension charge for 1st year , g3_27_warranty extension charge for 2nd year , g4_28_auxiliary fw cooling pump with accessory , g4_29_on board spares for aux. fw cooling pump , g4_30_documentation for aux. fw cooling pump , g4_31_tools for auxiliary fw cooling pump , g4_32_instl - comm spares for aux fw cool pump , g4_33_training for auxiliary fw cooling pump , g4_34_service of engineers , g4_35_warranty extension charge for 1st year , g4_36_warranty extension charge for 2nd year , g5_37_cooling water transfer pump plus accessories , g5_38_onboard spare for cool water trnsfr pump , g5_39_document for cooling water transfer pump , g5_40_tools for cooling water transfer pump , g5_41_instl-comm spares for cool w trnsfr pump , g5_42_training for cooling water transfer pump , g5_43_service of engineers , g5_44_warranty extension charge for 1st year , g5_45_warranty extension charge for 2nd year , g6_46_fw circulation pump with accessories , g6_47_on board spares for fw circulation pump , g6_48_documentation for fw circulation pump , g6_49_tools for fw circulation pump , g6_50_instl - comm spares for fw circ. pump , g6_51_training for fw circulation pump , g6_52_service of engineers , g6_53_warranty extension charge for 1st year , g6_54_warranty extension charge for 2nd year , g7_55_lube oil transfer pump with accessories , g7_56_onboard spare for lube oil transfer pump , g7_57_documentation for lube oil transfer pump , g7_58_tools for lube oil transfer pump , g7_59_instl - comm spares for lo transfer pump , g7_60_training for lube oil transfer pump , g7_61_service of engineers , g7_62_warranty extension charge for 1st year , g7_63_warranty extension charge for 2nd year , g8_64_dirty oil transfer pump with accessories , g8_65_onboard spare for dirty oil transfr pump , g8_66_document for dirty oil transfer pump , g8_67_tools for dirty oil transfer pump , g8_68_instl-comm spare_dirty oil transfer pump , g8_69_training for dirty oil transfer pump , g8_70_service of engineers , g8_71_warranty extension charge for 1st year , g8_72_warranty extension charge for 2nd year
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above