Get complete information related to latest Wire Fuse Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Wire Fuse Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Wire Fuse Tenders.
Tender For bid to ras bid to ras bid to ras supply of 250 a mccb 36 ka cat no du100d-250d of lauritz knudsen , mnx power contacor 3 pole of capacity 80 or 100 amp confirms to is , mcx 12 power contacor 4 pole of capacity 63 amp confirms to is , mcx 13 power contacor 4 pole of capacity 80 amp confirms to is , mcx 22 power contacor 4 pole of capacity 105 amp confirms to is , mcx 23 power contacor 4 pole of capacity each 130 amp confirms to is , battery terminals of copper wire frlsh 25 sqmm red and black for dg set 4 feet each , led post top lantern arian plus led type 30 watt warm white colour made in spun aluminium powder coated housing with higher efficiency lighting and ip 65 protection , led post top lantern arian plus led type 18 or 20 watt warm white colour made in spun aluminium powder coated housing with higher efficiency lighting and ip 65 protection with soft 360 , led post top lantern blaze b-1 22 holder without lamp dimension 200mm x 240mm higher efficiency lighting and ip 65 protection with soft 360 deg light distribution , automatic street light panel hgs smarty series of capacity 6 kw astronomical switch with mcb tpn 40 amp contactor of capacity 32 amp tp conforms to is , thermoplastic cable entry junction boxes lof size 300 x 200 x 105 mm and ip-65 protection level with metric knock out fixed on poles with ms clamps nuts bolts and washers including , ht insulation tape , ht pin insulator polymer , ht post insulator polymer , ht disc insulator polymer , ht do fusewire 10 amp , ht do fusewire 16 amp , ht do fusewire 25 amp , ht do fusewire 40 amp , pool standard g24 pool balance moudle to increase chlorine level in pool water target limit for free available chlorine granules packing 50 kgs in plastic container , pool standard b23 pool algaecide specifically effictive against green black spot and mustard algae packing 5 kgs sealed plastic container , pool standard a94 fast acting pool clarifier to clear dull hazy or cloudy water which can occur in newly filled pools during warm weather with pool start up , pool standard t19 pool balance module to check water ph plus chlorine test kit hardness kit packing strip in sealed plastic container , tube light reteofit 20 w led , mccb tpn 63 amp 415v 10ka c curv service wire 1100 volts grade heavy duty cable pvc insulated aluminium conductor 2. 5 sqmm 2 core served with inner sheathing of pvc tape and overall pvc sheathed in service connections, service wire 1100 volts grade aluminium conductor pvc insulated round sheathed flexible industrial cable 6 sqmm 2 core, service wire 1100 volts grade aluminium conductor pvc insulated round sheathed flexible industrial cable 10 sqmm 2 core, service wire 1100 volts grade aluminium conductor pvc insulated round sheathed flexible industrial cable 10 sqmm 4 core, service wire 1100 volts grade aluminium conductor pvc insulated round sheathed flexible industrial cable 16 sqmm 4 core, do fuse tinned copper wire 14 swg 200 gm roll, do fuse copper wire 18 swg 200 gm roll, do fuse copper wire 20 swg 200 gm roll, do fuse copper wire 21 swg 200 gm roll, ht insulation tape 19mmx18 point 3 mtr, lt aluminium terminal lugs suitable for cable size 16 sqmm, lt aluminium terminal lugs suitable for cable size 25 sqmm, lt aluminium terminal lugs suitable for cable size 35 sqmm, lt aluminium terminal lugs suitable for cable size 50 sqmm, lt aluminium terminal lugs suitable for cable size 70 sqmm, lt aluminium terminal lugs suitable for cable size 95 sqmm, lt aluminium terminal lugs suitable for cable size 120 sqmm, lt aluminium terminal lugs suitable for cable size 150 sqmm, lt aluminium terminal lugs suitable for cable size 185 sqmm, lt aluminium //bid details2 / 51
Tender For supply of overhauling & maintenance of cp transformer rectifier units , ac amp. meter, for detailed description refer price breakup sheet , ac volt meter, for detailed description refer price breakup sheet , dc volt meter, for detailed description refer price breakup sheet, dc amp. meter, for detailed description refer price breakup sheet, voltmeter ( psp meter ), for detailed description refer price breakup sheet, main rectifier diodes, iav 150 amp, piv - 1200 v , type- 150 lf 120 , "lightning arrestor( la) both input and output side, rms voltage rating - 500v ,rms current rating - 1.5 ka, type- lt 0.5 oe eqv", thyrister module (scrm) consisting two antiparrallel thyrister, for detailed description refer price breakup sheet, auxiliary transformer for control circuit power supply, for detailed description refer price breakup sheet, filter capacitor bank in dc output , 2500 micro farad , 150v x 6 electrolytic capacitors, relay for providing remote contacts for mcb tripped & ac supply fail faults , coil - 240 v ac coil resistance 10 k contacts 2no+2nc , 8 pin plug in type, relay for providing remote contacts for oil tank or instrument , chamber high temp. fault. coil - 240 v ac coil resistance 10 k contacts 3no+3nc , 11 pin plug in type, thermostate with adjustable temp. setting with nc contacts ( 30 to 110 setting ), indicator lamp , housed in 22.5 mm dia, 240 v, led type red colour, auto or manual mode selector rotary type, 4 pole , 2 way ,63 amps, 240 v, ac type srpm 5417b or pa 17463b, coarse manual output control switch , rotary type, 1 pole , 6 way ,63 amps, 240 v, ac type pa7163f, fine manual output control switch rotary type, 1 pole , 4 way ,63 amps, 240 v, ac type srpm 615dor pa 5163 d, coarse current limit settor switch cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, fine current limit settor switch, cam type, 2 pole ,6 way ,6 amps, 240 v, type s6-61072, reference electrode selector switch, cam type 2 pole ,4 way ,6 amps, 230 v, type s6-61070, local or remote control mode selector switch,toggle type 2 pole , 2 way ,6 amps, 240 v, , on or off toggle switches in various lamp and meter circuits. 1/2 pole , 2 way ,6 amps, 240 v, , current transformer for ammeter a1 ratio - 50/1, burden - 5 va ,class - 1, contactor 32 amp.bch make 3p +(1p no) with add on 240 v ac coil , breather ( 19.45 mm dia), output voltage setter potentiometer in local auto mode 2.5 k ohm 3 watt ww, output current setter potentiometer in local auto mode 1 k ohm 3 watt ww, oil temp. indicator range ( 0 to 150 o c ), 4-20ma converter module for dc output voltage signal input - 0-75v dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , 4-20ma converter module for dc output current signal input - 0-75a (75 mv) dc , output - 4 to 20 m a , max load - 600 ohm , accuracy - +-0.5 %, aux supply - 240 v, ac type-520 t, base or channel mounting type , "auto transformer with coarse and fine tappings for manual control dc of output, input -265 v , coarse taps- 7 nos. fine taps- 04 nos. capacity - 8000 va, insulation - class -a (oil cooled ) ", "main transformer with shield double wound primary- 240 +/- 10 %, secondary- (0-110 v), capacity - 10,000 va, insulation - class -a (oil cooled )", filter choke in dc output , 7.5 mh at 100 amp., control box for card fixing ceco-108 & ceco 105 d1 (and extra card connector having 40 slots), current or voltage control firing card control card , type- ceco- 105d1 , "remote control interface card control card ,type- ceco -108 ", "current limit setter card control card , type- ceco -35a- 2.5 v , 75a/75mv -33.33", "voltage current sensor card control card , type -ceco -19c ", pulse driver card ceco - 118 c, surge suppressor r-c network across scrs 75 ohm, for detailed description refer price breakup sheet, "fuse fail indicator module for diodes and output fuses six channel type with led indicators and 1 common no+nc contacts ,sensing
Tender For supply of auxilliary contact block, 3no, 3nc , power supply module 220v dc, part no. 701040041 , ammeter, 72 sq. mm , pt 1ph6. 6kv, 220v, 110v,300va,ep resincast , indicating lamp, 6w, 220v ac , busbar support, bs 60 , pt fuse support, bs 60fs , transformer, 1ph,2kva,6600v,220v,tf26220 , on off isolator, 400a, type. p3i, , vacuum contactor 220vac 400a, 6. 6kv , dc pack for closing coil, 220v dc, psm, , current trnsfrmr,100 5 5va,cl. 1,bt1g534m, , earth leakage relay with cbct , auxilliary contactor 2no, 2nc, 220v ac , ring type current transformer 80 5, 5va, part no. 0201040027 , main copper busbar with ht sleeving 25 x, part no. 0102040002 , control circuit breaker 6a. 2p,10ka, part no. 020109009 , main busbar holder 6. 6kv, part no. 060103000 , main fuse,80a,6. 6kv,type. hrc, part no. 0201160304 , vaccum contactor type. savac 4,400a,6. 6kv, part no. 0201200009 , vaccum inerrupter,6. 6kv,400a,, part no. 0701040017 , closing coil of vaccum contactor ,220v, part no. 0701040040 , 3 phase,3 limb,draw out type potential, part no. 0201040015 , motor protection relay, 220v,m pro 100, part no. 0201070045 , digital ammeter with built in ass 96x48, part no. 0201100221 , closing coil for vcb ,220v dc,, part no. 0201230002 , ht hrc fuse 150a, 6. 6kv, part no. 0201160286 , auto transformer w tpng,1000kw, 6. 6kv, part no. 0201040317 , motor protection relay 110vac, part no. 0201070025