Get complete information related to latest Worm Feeder Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Worm Feeder Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Worm Feeder Repair Tenders.
Tender For corrigendum : tender for the work of erection and maintenance of overhead 11kv ht line/lt line & transformer center at various areas under cyclone damage, rainfall damage , big tree fallen, roadside accident, rusted pole etc.(breakdown maintenance) circumstance on emergency restoring power supply works under jurisdiction of nanapondha sdn under dharampur division. if require work to be carried out at other sub-division under jurisdiction of dharampur division.
Tender For supply, test, transport, construction, erection, testing and commissioning of 1 x 5 mva substation and 33kv overhead line (2km) &underground feeder (1.00km 3c 300sqmm xlpe double run) for ht connection of load 2.5mva in r/o pme bus depot near miraj medical ground, miraj under 100% ddf scheme and other allied works
Tender For corrigendum : repair to ht/lt main and distribution electric panel including replacement of cradle guard ht/lt overhead line at talbehat mil stn
Tender For painting of lt/ht overhead line poles by aluminium colour epoxy paint after priming coat by zinc chromate primer and radium stickering with nomenclature on poles for identification of feeder no, pole no. and supply voltage etc under township rajrappa
Tender For segregation of 11 kv mixed feeders at tonk circles of jaipur discom of rajasthan state under revamped reforms-based and results linked distribution sector scheme (rdss) on turnkey basis against tn-583 - pcc poles, pcc pole 9 mtrs long (400 kg), pcc pole 9 mtrs long (200 kg), outdoor 11 kv o/d vcb kiosk complete with accessories including use of special tools, armoured cable of size 2c x 4 sq.mm. 1100 volts pvc insulated including supplyof ferrules, control cable of size 12c x 2.5 sq.mm. 1100 volts pvc insulated including supply of ferrules, overhead steel cored aluminum acsr dog[100sqmm(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing, overhead steel cored aluminum acsr rabbit conductor in all respect, earthing rod sets for s/s made with ms rod (galvanized ) 20 mm dia, 3 meter length with gi wire and clamp as per latest specification and drawing adopted & approved by nigam., ctpt structure set (galvanized), 11kv ct pt set(200/5 amp.), mip meter box for meter with ttb, go double break without eb isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc., 11kv ( with 9 x 24 kv post insulator ) 400 amp., horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc., 11kv ( with 6 x 24 kv post insulator ) 1 set=3 nos, supply of insulators, 11kv porcelain disc.insulators b&s type 45kn, hardware for 11kv disc insulator b&s type 45kn, composite polymer insulators, 11kv polymer disc.insulators t&c type 45kn, hardware for 11kv disc insulator t&c type 45kn, 11 kv composite polymer pin insulator complete in all respect, pg clamps for suitable acsr dog conductor, pg clamps for suitable acsr rabbit conductor, 11 kv danger plate of size 200 x 250 mm complete in all respect, supply of angle and channel, m.s channel 100x50x6 mm, m.s channel 75x40x6 mm, m.s. flat 50 x 6 mm (galvanized), 1.4 mtr channel bracket with clamp, supply of lightening arrestors, substation type 9kv, 10ka station class (1set=3 nos.) lightening arrestors., 11kv double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from m.s.channel 100 x 50 x ismc ( 9.56 kg. per mtr.) isa m.s.angle 65 x 65 x 6 mm, m.s.angle 50 x 50 x 6 mm and m.s.flat 50 x 6 mm (galvanized as per is), gi stay set (galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300x300x4 mm,12 mm dia turn buckle) including stay clamps,, strain/guy insulator for stay set, 7/10 swg gi stay wire, gi wire 8swg, underground cable for working voltage of 11kv aluminium conductor (is 7098) cable xlpe armoured, under ground cable of size 3x185 sq.mm for 11 kv, g.i. pipe of 125 mm diameter, b-class (is:1239 mark), gi pipe for cable support at pole ( each 3.3 mtr ), cable for11 kv aluminum conductor xlpe armoured ht cable, xlpe 3x185 sq.mm h.s. on indoor type, xlpe 3x185 sq.mm h.s. on outdoor type, xlpe 3x185 sq.mm h.s.s.t. joint, 11.4 mtr. long lattice tower made of 50 x 50 x 6 mm m.s. angle with 50 x 6 mm m.s. flat for bracing as per nigam specification, 11kv cross arm with top hamper with clamps made of ms angle 65x65x6mm, clamp 50x6 mm, earth clamp 50x6 mm (galvanized), fixing of 11/0.4 kv substation structure set for three phase 63 kva transformer on double poles in all respect. weight (as per specification and drawing with go channel) approx=219.54 kg (all galvanized as per relevant is), 11 /0.4 kv al wound, three phase distribution transformer (completely self protected with provision of lt bushing box), 25 kva, 63 kva, 6.35/0.24kv s/s structure set for single phase transformer on single 9mtr, 400kg pcc pole in all respects., 11kv 100 amp drop out cum isolator with 3.0 amp. fuse & 12 kv post insulators., lt xlpe cable, size 4cx70 sq. mm, size 4cx120 sq. mm, aerial bunched cable, aerial bunched cable 3cx25+1x25 sqmm, aerial bunched cable 3cx50+1x35 sqmm, lt distribution pillar
Tender For corrigendum : tender for provide knowledge skill person and overseers for 11kv/22kv underground cable/overhead line for ht cable route patrolling, cable safe guarding, cable fault joint pit excavation etc. work as per instruction of engineer in charge under sachin-1 ind sdn under surat (industrial) division.