Tender For supply of laboratory and scientific equipment/tools - laboratory and scientific instruments/tools, compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r22, cooling capacity: 2355 kcal/hr type, voltage 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r134a, cooling capacity: 1411kcal/hr, voltage: 440vac, 25mfd, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type:r134a, cooling capacity: 0.25hp; supply voltage: 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., capillary tube : 1.12 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.20 mm od, 8 ft, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.40 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 0.95 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., thermostatic expansion valve: orifice- 0 no., connection-1/2 x 3/8 flare (details as per sl. no. 3 at annexure-i)., thermostatic expansion valve: ten 068z3348, q-33311 r134a -40 to 10 ps 34 bar. (details as per sl. no. 3 at annexure-i)., hand stop /manual shut-off valve: media: r22, r502, r134a, r407c, r410a; port size: 3/8" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., hand stop /manual shut-off valve: media: media: r22, r502, r134a, r407c, r410a; port size: 1/4" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., evaporator coil : 1/4" od, material: copper astm b280 (details as per sl. no. 5 at annexure-i)., condenser coil ; 3/8" od, material: copper astm b280 (details as per sl. no. 6 at annexure-i)., dimmer stat : 1500 w, 230 v ac. single phase, 50hz (details as per sl. no. 7 at annexure-i)., pressure gauge : connection 1/ npt 8 0 - 200 psi dial size 2.5" (63mm), connection sizes 1/4" (details as per sl. no. 8 at annexure-i)., digital temperature indicator : range -30 to 200 0c, power supply 230vac, digital display, accuracy 0.01 c channel -12 (details as per sl. no. 9 at annexure-i)., digital temperature indicator : type input cr-al(k-type), rang- 0 0c to 200 0c supply- 230vac, 50hz, channel -12 (details as per sl. no. 9 at annexure-i)., ammeter (digital) : rang 0-10 amp. single phase, digital display, 230v,10%vac (details as per sl. no. 10 at annexure-i)., voltmeter (digital) : rang 0 300-volt, single phase, digital display (details as per sl. no. 11 at annexure-i)., hp/lp cut out relay : hp- 8 to 32 bar, lp-0.2 to 7.5 bar, dual controls, 240 v, 50 va, single pole changeover switch (spdt), contact load 240 v ac: 8 fla, 48 lra (details as per sl. no. 12 at annexure-i)., energy meter : a.c. single phase, 2 wire solid state (static) fully electronic energy meter, accuracy class 1.0 & current rating 5-30 amp. with backlit lcd display for240 volt system fitted with pilfer proof meter box.(details as per sl. no. 13 at annexure-i)., r-134a refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; application: refrigerant; type of refrigerant-r134a. (details as per sl. no. 14 at annexure-i)., r-141b refrigerant gas : 5 kg filled cylinder; purity 99.9% appearance: colourless (details as per sl. no. 15 at annexure-a)., r502 refrigerant gas : 5 kg filled cylinder; acidity 0.00001 % appearance: colourless purity 99.9 % (details as per sl. no. 16 at annexure-i)., r407c refrigerant gas : 5 kg filled cylinder; appearance: colourless purity 99.9 % (details as per sl. no. 17 at annexure-i)., r-1234ze hfo refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; (det
Tender For tender for supply of pendant control (8 button) for electrical hoist, t-track system (including trailing cable, wire rope, cable trolly, angle iron bracket, t section) for 2ton capacity hoist, dc break electromag netic disc type dc-14.448 size 18 hoist for 10 tons hoist, ac break electromag netic disc type, 3 phase, 415v hoist for 5 tons hoist, ac break electromag netic disc type, 3 phase, 415v hoist for 3 tons hoist, solid state rectifier, 440v ac/190vdc, 2amp, lever type limit switch for ct/lt ct limit switches 10 amps 1no+1nc make-jai balaji
Tender For supply of maintenance of diesel engine alternator sets in various sites under ba alwar - visit charges to attend fault of dea set , general servicing of the up to 20 kva dea sets , general servicing of more than 20 kva and upto 32.5 kva dea sets , general servicing of more than 32.5 kva and up to 55 kva dea sets , replacement of diesel filter element set 1 ltr , replacement of oil filter element 1 by 2 ltr , replacement of oil filter element 1 ltr , replacement of diesel filter element set 1 by 2 ltr , replacement of oil filter set suitable for ea set of 50 to 55 kva , replacement of lubricating oil multi grade 20w40 , replacement of steel wire braided fuel pipe line , replacement of stop solenoid 12 volt , replacement of starting key with switch , replacement of mechanical type rpm cum hr meter , replacement of mechanical type rpm cum hr meter chain , replacement of battery leads red and black , replacement of coolant for radiator of superior quality , replacement of v belt , replacement of hose pipe set with clips , replacement of techo drive unit , replacement of fuel feed pump assembly , replacement of solid state smps or scr based battery chargers , replacement of push button switch for start or stop or reset , replacement of 12 v dc or 220 v ac hr meter counter type , supply and fixing of 12 volt battery operated self starter , supplying and fixing of 12 volt battery charging alternator , repairing of 12 volt battery charging alternator , repairing and general servicing of the existing faulty radiator up to 55 kva , pdg general servicing and repairing of 12 volts engine starting self , dismentalling of existing up to 20 kva dea sets , dismentalling of existing more than 20 kva and upto 55 kva dea sets , extra for shifting of existing dea set up to 20 kva , loading of existing up to 20 kva dea sets , loading of existing more than 20 kva and upto 55 kva dea sets , transportation of up to 20 kva dea sets , transportation of more than 20 kva and upto 55 kva dea sets , unloading up to 20 kva dea sets , unloading more than 20 kva and upto 55 kva dea , itc of up to 20 kva dea sets on existing foundation , itc of more than 20 kva and upto 55 kva dea , labour charges for top overhauling of existing dea sets up to 20 kva , replacement of the liner assembly with rubber ring dea sets up to 20 kva , replacement of the piston set without piston ring set dea sets up to 20 kva , replacement of the piston ring set dea sets up to 20 kva , replacement of the set of gasket including head gasket dea sets up to 20 kva , replacement of the o ring set dea sets up to 20 kva , replacement of the cr bearing dea sets up to 20 kva , replacement of the main bearing dea sets up to 20 kva , replacement of the oil pressure guage dea sets up to 20 kva , replacement of the front oil seal of crank shaft dea sets up to 20 kva , replacement of the back oil seal of crank shaft dea sets up to 20 kva , labour charges for top overhauling of more than 20 kva and upto 55 kva , replacement of the liner assembly with rubber ring dea sets more than 20 kva and upto 55 kva , replacement of the piston set without piston ring set dea sets more than 20 kva and upto 55 kva , replacement of the piston ring set dea sets more than 20 kva and upto 55 kva , replacement of the set of gasket and head gasket dea sets more than 20 kva and upto 55 kva , replacement of the o ring set dea sets more than 20 kva and upto 55 kva , replacement of the cr bearing dea sets more than 20 kva and upto 55 kva , replacement of the main bearing dea setsmore than 20 kva and upto 55 kva , replacement of the oil pressure guage dea sets more than 20 kva and upto 55 kva , replacement of the front oil seal of crank shaft dea sets more than 20 kva and upto 55 kva , replacement of the back oil seal of crank shaft dea sets more than 20 kva and upto 55 kva , repairing of cylinder head , repairing of up to 20 kva dea sets crank shaft , repairing of more than 20 kva and upto 55 kva dea sets crank shaft , tran