Web Analytics Made Easy - StatCounter

Zonel Work Tenders

Get complete information related to latest Zonel Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Zonel Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Zonel Work Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40951200 Due date: 10 Jul, 202510 Jul, 2025 6.86 Lacs
Tender For repair work chemistry lab, room no. 133, 134 and outer wall in govt. bangur college

Central Government/Public Sector

CTN :40951026 Due date: 24 Jul, 202524 Jul, 2025 43.80 Lacs
Tender For addn / altn and special repair of toilet, vertified tile in lab (03), main office (01) and main entrance of secondary block under age br(s) no-ii of ge (south) secunderabad

CTN :40960874 Due date: 15 Jul, 202515 Jul, 2025 5.67 Lacs
Tender For repair & renovation work of c.s. media section & decontamination room at cri kasauli (h.p.) sh: providing and fixing false ceiling in rooms, painting and distempering in nsec lab at cri kasauli

CTN :40949182 Due date: 10 Jul, 202510 Jul, 2025 NA
Tender For providers for the repair and replacement split ac of thr vlsi design lab entc old building

CTN :40948899 Due date: 08 Jul, 202508 Jul, 2025 NA
Tender For quotation for repair and renovation of chemistry lab at 1st floor in home science building at sndt women's university pune campus

CTN :40966577 Due date: 12 Jul, 202512 Jul, 2025 1.80 Crore
Tender For e-procurement tender for fire renovation work for lab, electrical control panel, and air handling system repair and restoration

CTN :40703033 Due date: 07 Jul, 202507 Jul, 2025 NA
Tender For corrigendum : augmented opto electronic repair facility along the existing infrastructure of gce lab - aluminum paneled structure , false ceiling alongwith supporting structure , wall mounted fan with wiring , surface lights with wiring , exhaust fan with wiring

Central Government/Public Sector

CTN :40758970 Due date: 11 Jul, 202511 Jul, 2025 9.00 Lacs
Tender For corrigendum : repair and maintenance of split ac, window type ac, water cooler and desert cooler installed at defence lab jodhpur

Corporations And Associations And Others

CTN :40937203 Due date: 10 Jul, 202510 Jul, 2025 4.74 Lacs
Tender For procurement of electrical material for day to day repair and maintenance at various ctcs (community toilet complexes) and pts (public toilets) under south zone (for swachhta survekshan - 2025) - rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm. frls pvc insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/pvc conduit including dismantling as required.group c, supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3x1.5 sq. mm, supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required. 3x2.5 sq. mm, supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as required. (a)5/6 amps switch, supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 3 pin 5/6 a socket outlet, supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 a socket outlet and 15/16 a piano type switch, connections, painting etc. as required., installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.upto 450 mm sweep, supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, "c" curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole, supplying and fixing following rating ,double pole,240 volt,isolator in the existing mcb db complete with connections,testing and commissioning etc. as required.(b) 63 amps, supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan fresh air type complete with shutter blades etc. as required., supplying, installation, testing & commissioning of led surface mountedbatten light of following body material and construction as per is : 10322with driver (replaceable) as per the requirement with driver efficiency>85% ,operating voltage ac 140-270 volt, freq 50/60 hz, operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 kv withshort & open circuit protection ,thd 10% , p. f. 0.95, ip20, cri >80,flicker free, (flicker should be below 5 %), life time (led,driver & electricalcircuitary), of minimum 50000 burning hours with , 70% of initiallumen maintained till life ends, cct 3000 k / 4000 k / 5700 k/6000 k/6500 k (as per ansi bin), sdcm(standard deviation colormatching) 3, maximum power consumption should not more than thespecified rating and fixture shall be of relevant bis standard and trademark certificate ( t.c.). manufactures word mark/ name engraved/embossing/ screen printing on housing. complete in all respect i/cconnections with 1.5 sq mm frls, pvc insulated copper conductorsingle core cable and earthing etc. as required with minimum 5 year oemwarranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80test report from nabl lab for all testing required for led fixtures asper bis shall be submitted. shape size and cct shall be as approved byengineer-in-charge as per requirement. (thermal management: heat sinkof aluminum housing such that led junction temperature shall not riseabove 90 c). 18- 22 watt, supply,installation,testing and commissioning of single /three phase monoblock pumpset complete with all accessories workable on 240/

corporations/Associations/Others

CTN :40922458 Due date: 23 Jul, 202523 Jul, 2025 NA
Tender For tender for supply of chemical vulcanizing fluid l liter packing lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.701076 400380101 0000. , precured patch for cut size tyre patch-injury 2 inch(50mm) 16 pr lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010 751 8038 0106 0006 , redial patch ct-12 size 60x110mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010757203801000000 , redial patch ct-20 size 75x125mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010757803801000000 , redial patch ct-26 size 75x250mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010758403601010001 , redial patch ct-35 size 125x150mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010758403801030003 , redial patch ct-40 size 100x200mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010758603801000000 , redial patch ct-45 size 195x230mm lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.npn , two way tube repair unit patch 25 mm (1.00 inch)mini round 1 packet containing 50 patches lab test test carried out as per specification no.as 164 69 july 2005 as per 10asrtu code no.7010770703801000000 , two way tube repair unit patch 30 mm (1.1/4 inch) small round 1 packet containing 40 patches lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010770903801000000 , two way tube repair unit patch 53 mm (2.1/8 inch) medium round 1 packet containing 30 patches lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010771103801000000 , two way tube repair unit patch 75 mm (3 inch) large round 1 packet containing 30 patches lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010771303801000000 , two way tube repair unit patch 100 mm (4 inch) round lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010771503801000000 , two way tube repair unit patch 118x37mm (4. 1/2 inch to 1. 1/2 inch) small oval patch 1 packet containing 100 patches lab test carried out as per specification no.as 164 69 july 2005 as per asrtu code no.7010772703801000000 , two way tube repair unit patch 130x75mm(5. 1/4 x 3 inch)medium oval patch lab test carried out as per specification no. as 164 69 july 2005 as per asrtu code no.7010773103801000000
 Loading, Please wait...

Connect us via What's Up