Tender For corrigendum : supply of led luminaire for floodlight conforming to is 10322 (part 5/section 5) (v3) (under bis scheme - ii) (q2) , led luminaire for road and street lights conforming to is 10322 (part 5/section 3) (v3) (under bis scheme - ii) (q2) , led batten light (led tube light) (v2) (q2)
Tender For corrigendum : laying, jointing, shifting and dismantling of 10 12 inch (250 and 300 mm) diameter ms and lay flat pipeline, for dewatering from active coal faces and various sumps for 730 days as and when required at bina project
Tender For corrigendum : providing of facility management services - lumpsum based - industrial; hiring of air coolers for various offices and rooms of service buildings of mines area of bina project; consumables to be provided by service provider (inclusive in contract cost)
Tender For bid to ras supply of repair minor maintenance of complete electrical system at awrs etp , removal reinstallation replacement of 0. 4 kv, 160 to 200 kw motors , removal reinstallation replacement of 0. 4 kv, 130 kw motors , removal reinstallation replacement of 0. 4 kv, 30 kw motors , removal re-installation replacement of 0. 4 kv, 0. 7kw to 5. 5 kw motors , servicing maintenance of bearings testing of 0. 4 kv 130 kw motors , servicing maintenance of bearings testing of 0. 4 kv 130kw upto 200 kwl motors , servicing maintenance of bearings testing of 0. 4 kv 375 kw motors , servicing maintenance of bearings testing of 0. 4 kv 30 kw motors , servicing maintenance of bearings testing of 0. 4 kv 0. 7kw to 5. 5 kw motors , servicing maintenance testing of modules of motors incomer section up to 200 kw , laying of l. t power cable 3c x 26 to 240 mm2 3. 5c x 25 to 185 mm2 , aying of l. t power cable 1c x 1000 mm2 2c x 400 mm2 , end termination of power cable 3c x 26 to 240 mm2 3. 5c x 25 to 185 mm2 , end termination of power cable 1c x1000 mm2 2c x 400 mm2 , oh cleaning reconditioning 200ah- 600ah batteries 350v-360v dc , load test for various size battery of ups , oh of bus bars tightness checking and replacement of damaged switches , cleaning and painting of the wooden battery stands of ups , amc of air conditioners repairing and servicing , gas charging work of ac , rewinding of burnt fan motor of air conditioners , repairing of actuators of nozzle valves , repairing of flame scanner system , repairing of hea system , repairing of solenoids of hag , repairing of actuators had and cad , repairing servicing and installation at site of atomizing steam nozzle valve ) /bid number: gem/2026/b/7314308 * /dated: 05-03-2026 & & / bid document1 / 27
Tender For corrigendum : supply, installation and comprehensive maintenance (02 years ) of 2 nos. electro magnetic flow meter ( 01 nos. 150 mm and 01 nos. 200 mm)