Web Analytics Made Easy - StatCounter

Srinagar Tenders

Get complete information related to latest Srinagar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Srinagar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Srinagar Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40422948 Due date: 04 Jun, 202504 Jun, 2025 6.12 Lacs
Tender For supply, installation, testing and commissioning of the hot and cold ac units in mru at govt. medical college, srinagar

CTN :40404023 Due date: 09 Jun, 202509 Jun, 2025 NA
Tender For supply of lp medical - lignocaine hcl jelly 2p tube of 30gm , common cold tab cet5 10gm para 500mg pseudo 30 60mg , diclofenac 25mg ml ip 3 ml inj , ibuprofen 200 mg tab , ibuprofen syrup 100mg 5ml bott of 50ml , paracetamol syp 125mg 5ml bottle , etoricoxib 120mg tab , morphine 15 mg 1ml inj , tramadol hcl 50mg capt tab , aceclofenac 100mg tab , febuxostat 40mg tab , levo cetirzine 5mg tab , pheniramine maleate inj 22.75mg , levetiracetam 500mg tab , oxcarbazepine 150mg tab , clobazam 5mg tab , clonazepam 2mg tab , diazepam 10mg 2ml inj , gabapentin 300mg cap

State Government

CTN :40422972 Due date: 30 May, 202530 May, 2025 25.24 Lacs
Tender For supply, installation, testing and commissioning of washing machines in laundry and linen department main hospital skims soura

State Government

CTN :39307900 Due date: 30 May, 202530 May, 2025 9.28 Crore
Tender For corrigendum : work of development of 24x7 wss in ward 2 of nishat area by way of sdltc of separate pipe network including all work of mech, elec., scada, household connections, consumer water meter fitting--- and associated e-m and civil works at harwan (sarband)

CTN :40397793 Due date: 26 May, 202526 May, 2025 NA
Tender For development of farm field by way of filling good earth at south campus sallar (bagwani) (hadp), skuast-k

corporations/Associations/Others

CTN :39724301 Due date: 12 Jun, 202512 Jun, 2025 NA
Tender For corrigendum : supply installation commissioning and operation of automated testing station centre at 2 locations in jkrtc bikram chowk jammu and central workshop pampore srinagar on ppp mode

CTN :40403819 Due date: 10 Jun, 202510 Jun, 2025 NA
Tender For supply of veh mt spares parts - lv7 stln vf 6220 72 000403 light assy indicator , lv7 stln 6240 013624 lamp incandecent , lv7 stln 6240- 0136633 lamp incandescent , lv7 stln f 3580411 wheel bolt m22 x 1.5 , lv7 stln f 8284000 air filter safety , lv7 mpvy 645 10 1011 i wind shield glass

CTN :40397834 Due date: 30 May, 202530 May, 2025 NA
Tender For diagnostic and therapeutic items for cardiac cath lab (group a) - us fda approved 1.5 & 3t whole body mri compatible a. single chamber latest generation rateresponsivepacemaker(aair/vvir)fullyautomatic with capture management and sensitivity management for rv with limited warranty (to be mentioned in years) plusb. =/ 7 fr. compatible leads (tined or screw-in) plusc. lead introducer set, us fda approved 1.5 & 3t whole body mri compatible a. single chamber latest generation rateresponsivepacemaker(aair/vvir)fullyautomatic with capture management and sensitivity management for rv with lifetime warranty plusb. = / 7 fr. compatible leads ( tined or screw-in )plusc. lead introducer set, us fda approved 1.5 & 3t whole body mri compatible a. single chamber latest generation rateresponsivepacemaker suitableforneonatesandinfants(aair/vvir),fullyautomatic with capture management and sensitivity management for rv with limited warranty (to be mentioned in years) plus b. = / 7 fr. compatible leads (tined or screw-in )plusc. lead introducer set, us fda approved 1.5 & 3t whole body mri compatible a. multi-programmable latest generation dual chamber pacemaker (dddr) with limited warranty with (to be mentioned in years) fullyautomatic with capture management and sensitivity management for ra and rv with advanced features like:1. modebasedreductioninrvpacingorequivalent.2. ratedropresponseorequivalent& 3.high atrial and ventricular rate detection. b. = / 7 fr. compatible ra ( tined or screw-in )c. rv leads ( tined or screw-in ) plusd. lead introducer sets, us fda approved 1.5 & 3t whole body mri compatible a. multi-programmable latest generation dual chamber pacemaker (dddr) with lifetime warranty fullyautomatic with capture management and sensitivity management for ra and rv with advanced features like:1 modebasedreductioninrvpacingor equivalent.2 ratedropresponseorequivalent&3. high atrial and ventricular rate detection. b. = / 7 fr. compatible ra ( tined or screw-in )c. rv leads ( tined or screw-in ) plus d. lead introducer sets, us fda approved 1.5 & 3t whole body mri compatible a. multi-programmable latest generation dual chamber pacemaker (dddr) with lifetime warranty fullyautomatic with capture management and sensitivity management for ra and rv with advanced features in addition to that mentioned below.(advanced features will be examined by the technical committee as per the patient requirements).1 modebasedreductioninrvpacingorequivalent.2 ratedropresponseorequivalent&3.high atrial and ventricular rate detection. b. = / 7 fr. compatible ra ( tined or screw-in )c. rv leads ( tined or screw-in ) plus d. lead introducer sets, us fda approved 1.5 & 3t whole body mri compatible a. multi-programmable latest generation dual chamber pacemaker (dddr) with limited warrantyfullyautomatic with capture management and sensitivity management for ra and rv with advanced features like:1. modebasedreductioninrvpacingorequivalent.2. ratedropresponseorequivalent& 3.high atrial and ventricular rate detectionb. = / 7 fr. compatible ra lead( tined or screw-in )c. lbbap lead d. lbbap delivery system plus e. lead introducer sets, eu ce approved 1.5 & 3t whole body mri compatible a. multi-programmable latest generation dual chamber pacemaker (dddr) with limited warranty fullyautomatic with capture management and sensitivity management for ra and rv with advanced features like:1.modebasedreductioninrvpacingorequivalent.2. ratedropresponseorequivalent&3.high atrial and ventricular rate detectionb. = / 7 fr. compatible ra lead (tined or screw-in) c. lbbap lead d. lbbap delivery system pluse. lead introducer sets, us fda approved 1.5 & 3t whole body mri compatible a. multi-programmable latest generation dual chamber pacemaker (dddr) with lifetime warranty fullyautomatic with capture management and sensitivity management for ra and rv with advanced features like:1. modebasedreductioninrvpacingorequivalent.2. rat

CTN :40397835 Due date: 30 May, 202530 May, 2025 NA
Tender For diagnostic and therapeutic items for cardiac cath lab (group b) - ecgelectrodesofhighqualitymaterialtominimize interference and signal distortion during prolonged cardiology procedurest (fda/ce approved), manifoldwithtwosideportsforptca(fda/ce approved), manifoldwiththreesideportsforptca(fda/ce approved), tefloncoatedguidewires(j-tip&straight-tip)standard length-145 or 150cm (fda/ce approved), tefloncoatedguidewires(j-tips&straight-tip)exchange length-260 or 300cm (fda/ce approved), femoral introducer sheath with puncture needle for adults (sizes 5 - 11 fr.) standard length; 10-16-25 cm long; 0.021 or 0.025-inch guide wire compatible. material of sheath tubing should be made of etfe, cross cut valve should be made up of silicon rubber & should have silicone coating. dilator tube should be made up of polypropylene and should have silicon coating. must have with haemostatic crosscut valve; with integrated side arm with attached 3-way stopcock; with suture eye for securing sheath and click sound; kink resistant. must have with dilator-hub lock mechanism to prevent its back-out during insertion; pack must include with or without metallic needle usfda approved, longintroducersheath(20-50cmlong)(fda/ce approved), extra-longintroducersheath(>50cm)(fda/ceapproved), radial introducer kit with puncture needle for adults (sizes 5 - 7 fr.) standard length 7 cm long; 0.035 or 0.038-inch guide wire compatible, include surflash 20g*2 entry needle (plastic iv catheter) and 0.025 mini plastic guidewire must have etfe sheath tubing, dilator tube should be made up of polypropylene and should have silicon coating.should contain a haemostatic crosscut valve to prevent back leak of blood and aspiration of air; with integrated side arm with attached 3-way stopcock, transradialcoronarydiagnosticcatheter (us fda approved) of various lengths, syringeforpressureinjector-150mlwithpressuretubing compatiblewiththeavailablesysteminthecathlab(medred-mark-7)arterion, highpressureconnectingtubingupto50cmslong for pressuresyringe, a). coronarydiagnosticangiographycatheter(judkinstype- leftandright)(us fda, b). coronary diagnostic angiography catheters ( judkins type) europeanceapproved), a). diagnosticcoronaryangiographycatheter(amplatztype- leftandright)(us fda), b). diagnostic coronary angiographic catheter ( amplaz type left &righceapproved), pigtailcatheters(fda/ceapproved), shortpigtailforpericardiocentesis, diagnosticmultipurposecatheters(fda/ceapproved), nihcatheter(fda/ceapproved), imacatheter(fda/ceapproved), ptcainflationdevice-analogdisplay(ballooninflation, deviceanalogdisplay,30atmpressurewithtubingand3, waystopcock)(fda/ceapproved), y-connectorsetwithextensiontubingtuohyburst,pci, needleand3-way, specialy-connectorsetwithbothfixedandhaemostatic, valvewithupto10frinnerdiameter, pcineedlewith/withouttorquerdevice, disposableplasticsterileluerlocksyringerfor angiographyandptca(leurlock), largelumenptcaguidingcathetersof5to8fr sizes-fda approved, largelumenptcaguidingcathetersof5to8fr sizes-ce approved, brkneedle(fda/ceapproved)for paediatrics/adults, embolicprotection(distalprotection)device(epd)for ptca (fda approved), embolicprotection(distalprotection)device(epd)for ptca (ce approved), manualthrombosuctioncatheterforptca(fda approved), manualthrombosuctioncatheterforptca(ceapproved), radialarterycompressiondevice, crossoverarterialsheaths(fdaapproved), snareloop(fdaapproved), snareloop(ce approved), micrograbber(fda approved), micrograbber(ceapproved), intravascularretrieversnareofvarioussizeswithsingle foldable loop, intravascularretrieversnare-twoloops(gooseneck type), intravascularretrieversnare-threeormoreloops (gooseneck type), pericardiocentesiskit(fda/ceapproved), pigtailcatheterwithmultiplemarkers(fdaapproved), rotalinkplussystem, rotalinkprosystem, rotalinkguidewire, intracoronarypressurewire(ffr)forptca-compatible with abbott vascular, ivuscatheterforcoronaryinterventionscompatiblewith boston scientific vascular, ivushdco

CTN :40336551 Due date: 22 May, 202522 May, 2025 NA
Tender For bid to ras supply of cashew kernels whole raw (grade 240) (v2) (defence) (q2)
 Loading, Please wait...

Connect us via What's Up