Get complete information related to latest Drilling Work Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Drilling Work Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Drilling Work Tenders.
Tender For design, supply, drilling, lowering, installation, testing and commissioning of borewell works with associated electrical, mechanical & civil works for establishment of amulfed-ii dairy at gadhka, rajkot (gujarat)
Tender For tender for supply of consumables for iapa compressors 53 gb01a b from oem ms fs elliot : : - o ring 0.139 , shaft seal o ring drive gear , pn ep0536 1 intercooler head gasket , oil filter element duplex , ring retaining , pump repair kit minor iron case(repair k , carbon seal repair kit hs and ls pinion , 53gb01 oil mist assembly p n tp2193 10 , inlet filter element secondary , inlet filter element primary , intercooler bundle gasket pkg lp , intercooler bundle gasket pkg hp , 53 gb 1ab victulic gsk 8 1st stg outlet , 53 gb 1ab victaulic gsk 5 3rd stage , 53 gb 1ab victaulic gsk 6 2nd stage
Tender For operation and maintenance operation and maintenance earth bund repairs works for polaiahkunta in nayakulagudem village sujathanagar mandal bhadradri kothagudem district
Tender For supply of accessories for hq size core drilling for preliminary exploration (g3) for ree - 5" 3-wing drag bit with cutting edges, hard faced with t.c. particles., hq water swivel , hq hoisting plug, hq drill rod 3 mtr. long (hcp), hq drill rod 1.5 mtr. long (hcp), hq drill rod 1.0 mtr. long (hcp), hq rod recovery tap (male), hq d.t. core barrel 3.0 m long , hq core barrel inner tube assy., hq core lifter, hq core lifter case, hq stabilizer, hq stop ring, hq landing ring, hq overshot assy., hq drill rod full grip wrench , hq inner tube full grip wrench, hq imp. core bit 150 cts., hq reaming shell 10 cts.,, 15/25 spc, hw cross chopping bit with hq box, hq jar collar, hw csg jar collar with hq box, hw csg drive shoe, hw casing 3 m long. , hw - do - 1.5 m long , hw - do - 0.6 m long , hw - do - 0.3 m long , hq rod box to hw casing pin, hw casing recovery tap, hw casing shoe 60 cts, hq3 core barrel 3.0 m long, hq3 core barrel 1.5 m long, hq3 imp core bit 130 cts, hq3 core lifter, hq3 core lifter case, hq3 stop ring, hq3 inner tube assy 3.0 m long, hq3 inner tube assy 1.5 m long
Tender For supply of electric pedestal type fan and regulator as per is 1169 (q2) , supply and fix water cooler capacity 80 litre , supply and fix deep freezer glass top 320 litres and having double door , supply and fix refrigerator capacity 310 litres bee 5 star , copper wire 1 point 5 sqmm 2c with accessories , switch socket combination 3 pin 5 or 6a , supply and fix switch socket combination 5 in 1 and 5 or 16 amps , m and l for sub main wiring with 3 run of single core 2 point 5 sqmm , supply install testing and commissioning of 50 kva voltage stabilizer , m and l for pipe earthing galvanised steel 40mm bore , supply and fix on load change over switch 4 pole 100a 415 volt
Tender For supply of a boring drilling 150 mm dia bore holes upto 10 mtr depth , b collection of disturbed and undisturbed soil sample at interval of 1 mtr , c to carry out the test to ascertain soil profile proportion to determine safe bearing capacity complete with field , d conduct lab test on disturbed soil samples , e conducting lab test on undisturbed soil sample as considered necessary according to relevant specification , g liquefaction analysis to be enclosed with the soil investigation report , h recommendation for pile foundation with pile capacity , submission of four copies of ink signed test report , the sbc of the soil is required to be given as per following table , with every site s soil investigation report a detailed site plan showing the approx location of each bore duly numbered as per log , every page of the soil investigation report , all pages of the soil investigation report shall be serially numbered, stamped and signed , transportation charges including loading and unloading of heavy girders , photographic record of geo explorations as well as testing shall also form part of the report , the ge shall intimate the approximate type of construction , in case of underground buildings basement construction
Tender For re-drilling, repairing and renovation of wta and pump house of kebalrampur (472/m) hdtw scheme block-hariharpara in the district of murshidabad under the e e (a-i), berhampore-i (a-i) division under core-sector programme for the f.y.2025-26
Tender For re-drilling, repairing and renovation of wta and construction of pump house of sripur (32/m) dtw scheme block-hariharpara in the district of murshidabad under the e e (a-i), berhampore-i (a-i) division under core sector programme for the f.y. 2025-26
Tender For repairing and strengthening of marginal bundh on r s of river ravi from rd 10125 rd 13000 to save c land bop ghaniye ke bet border fencing wire in dharmikota complex