Tender For supply of set of return air duct for wjcc coaches of bangladesh railways, as per drawing: mplradblwjcc version 0, packing instruction: frp ceiling sheet/side wall panels/frp component self adhesive biodegradable plastic lamination sheet to be provided on each component. projected metallic parts to be protected with plastic/nylon/frpcaps/proper wrapping of biodegradable bubble sheet from all the sides. each component to be packed in biodegradable bubble sheet all around with proper tapping & then to be placed incardboard box followed by 3 nylon strips tightened from both sides. then collective packs of components to be packed in wooden cage made from wooden strips of size 100x20mm & gap between each strip should not be more than 100mm.on the wooden crate base 3 wooden pegs of size100x100mm (along the length) to be provided for ease in handling with fork lifter. all loose items of a set to be packed separately in cardboard box with list of loose items pasted on each box and collective packs of item to be packed inwooden cage made from wooden . roof ceiling (having curved surfaces) in addition to above packing should be stacked on a metallic frames before packing in the wooden boxes. one package should not contain material belonging to more than one coach set & grouping should be preferably of similar sizes. also packing should have indication like 1/4,2/4 etc. ( e.g. four packings will make one coach set) so that one complete coach set can be easily identified. the maximum weight of the wooden crate should not be more than 200 kgs. a list should be pasted on each wooden crate showing order no, pl no. description of item, drg no/spec no/set list no. with version, qty, firm's name & address,date of dispatch etc. [ warranty period: 30 months after the date of delivery ]
Tender For supply of oil flow detector for 1578 kva bhel transformer. make- switzer flow switch type bgm-065-l115-f-4-fa-4-d-a or its equalent approved by rdso as per specification given. paddle operated flow switchenclosures: gm style alumimium pressure die cast weatherproof to ip66. line size: 65 mm line size flow range codes: 80 to 160 lpm switching direction: falling wetted parts, bm: 304 ss body, 316l ss bellows & 316 ss paddle flow switch process connection: flanged, 1 1/2"ansi, 150 rf (for line size 40...300 mm) process connection material: 304 stainless steel microswitch code: 15a,250v ac, spdt, general purpose micro switch electrical entry: 1/2 nptf, asme b1.20.1 single entry maximum working flow: 400 lpm repeatability :?2% of fsr seal "o" ring or sealing: buna-n "o" ring weld o let socket: without accessories: with accessories certificates: with certificates environment gaskets: buna-n type of service: general service list of accessories number of cable entries: single cable gland size: 1/2" nptm asme b1.20.1 cable gland 1: weatherproof double compression cable gland, nickel plated brass gauge cock: without [ warranty period: 30 months after the date of delivery ]
Tender For supply of spare parts of fire pump of m/s- flowmore india make - casing wearing ring, stuffing box bushing, impeller key, packing gland assembly, shaft sleeve (nde), shaft sleeve (de), sleeve nut and lock nut for sleeve (de), sleeve nut and lock nut for sleeve (nde), coupling key
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal agreement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is to beprovided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. [ warranty period: 30 months after the date of delivery ]
Tender For providing and fixing of v-belt link belt gland packing with provision of tyre coupling with pilot bore for smooth running of pumping operation under ashok project ppr area..