Get complete information related to latest Reservoir Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Reservoir Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Reservoir Tenders.
Tender For on risk & cost piped water supply scheme for village-chando(schooltola)block- balrampur, district balrampur(c.g.)construction, testing and commissioning of r.c.c. elevated service reservoir of 30 kl capacities 01 no. & staging 00 mtr, oht repairing {steel structure 12 m height & 10 kl (5000l x 2no.) 00 no. and steel structure 09 m height & 10 kl (5000l x 2no.)- 00 no.} of total - 00 nos. pe tank & elevated service reservoirs of rcc staging and hdpe slim tank of capacity 5000 ltr of 00 no. 9 mtr staging (with switch room of size 1.8mx1.8mx3m) and 10000 ltr of 00 no. 12 mtr staging.including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber.providing, laying, jointing, interconnection, testing and commissioning of rising main upvc class 10 kg/sqcm 90 mm dia 00 m & hdpe 75mm dia 600 m & 63 mm dia 00 m., distribution upvc class 6kg/sqcm 90mm dia. 1550 m., 110 mm dia. 00 m., 140 mm dia. 1710 m. 160 mm dia. 470 m.& distribution hdpe class 6kg/sqcm 63 mm dia. 1201 m., 75 mm dia. 636 m.with suitable joints gi pipe, valve, specials and all fittings including all allied civil works, supplying & installation of energy taging n five star bee rating isi marked required capacity single phase / three phase, 50 hz, 220v,, deep well submersible pump stainless steel body, suitable for 4/6 tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications butexcludingpipe,ss/nylonwireropeandconnection cable including verification of tubewell yield& electric connection from cspdcl, construction of brick masonry switch room, construction of boundary wall around the over head tank, installation of electro chlorinator , construction of chlorinator room of providing functional household tap connection (f.h.t.c. 76 ) in individual households and government instiution etc. complete with trial run of 03 months after that o&m of 06 months under piped water supply scheme under jal jeevan mission for village-chando(schooltola)block- balrampur, district balrampur(c.g.)
Tender For special repair to 1 lakh gallon semi-ug water rcc reservoir mes pump house and s and t-71 including fencing around the pump house under ge (i) jutogh
Tender For corrigendum : supply of resuscitation equipment- made, 3 provided with closed ended reservoir with two valves, 4, patient valves pliable, well sealed, have minimum dead space and no forward or, backward leaks, 5, the bag should have an oxygen inlet which fits into the standard oxygen tubing both from, a cylinder and central supply, 6, face masks should be transparent, fit the patient outlet easily and have minimum dead, space., 7 the system should withstand washing scrubbing and autoclaving procedures, 8 face masks : 3 sizes i.e. 00,01,02,: 3 set with each bag., 9 should have option to control peep & pip., b self inflating bags 500 ml, 1 self inflating bag, 2 single/double walled silicone made, 3 provided with closed ended reservoir with two valves, 4, patient valves pliable, well sealed, have minimum dead space and no forward or, backward leaks, 5, the bag should have an oxygen inlet which fits into the standard oxygen tubing both from, a cylinder and central supply, 6, face masks should be transparent, fit the patient outlet easily and have minimum dead, space., 7 the system should withstand washing scrubbing and autoclaving procedures, 8 face masks : 3 sizes i.e. 00,01,02,: 3 set with each bag., 9 should have option to control peep & pip., si no. self inflating bag 750ml, 1 self inflating bag, 2 silicone made, 3 provided with closed ended reservoir with two valves, 4, patient valves pliable, well sealed, have minimum dead space and no forward or, backward leaks, 5, the bag should have an oxygen inlet which fits into the standard oxygen tubing both from, a cylinder and central supply, 6, face masks should be transparent, fit the patient outlet easily and have minimum dead, space., 7 the system should withstand washing scrubbing and autoclaving procedures, 8 face masks : 3 sizes i.e. 00,01,02,: 3 set with each bag., 9 should have option to control peep & pip., si no. laryngoscope with different size blades-, 1 high quality corrosion resistant stainless steel blades and body, 2 light source firmly fixed with blade, 3 blades size 00,0 and 1,2,3 sets with each, 4 straight blade for neonatal use, 5 should withstand chemical sterilization and autoclaving, 6 should be having fiber optic cold light source ., 7 should have xenon light illumination of more than 50,000 lux., 8 battery should be rechargeable for more than 2 hr. -quantity - 10 -msme exemption - yes | startup exemption - yes,
Tender For providing pmc services including supervision, quality control for reconstruction of rcc box drain, u shape drain and construction of impounding reservoir in police quarters of chamrajpete constituency in west zone